Since 2000 · 3,000+ customers

Home / Large power supply repair / Overview

Power supply repair, testing and alternatives

Large power supply repair, testing and alternatives in India

Star Automations is an independent repair company in Puducherry. We repair, test, analyse and rebuild large industrial, high-voltage, medical, telecom, server and defence power supplies, and build retrofit alternatives for obsolete units. Send the nameplate and a photo of the fault.

01Anatomy

How a industrial power supply works and where it fails

Every power supply, from a 24 V industrial unit to a high-voltage generator, follows the same path: mains in, rectify, store, switch, transform, regulate. Faults cluster at a few points on that path. Star is an independent repair company, not an OEM service partner.

industrial power supply signal pathSignal path from the sensing element to the drive. Numbers mark the common failure points.Input stageFuse, filter, inrush1Rectifier and PFCBridge, PFC choke2Bulk capacitorsEnergy storage3Switching stageMOSFET or IGBT4Transformer and outputMagnetics, rectifier5Control and feedbackIC, optocoupler, sense6
  1. Input stage: Fuse, EMI filter, varistor and inrush limiter take the first hit from surges.
  2. Rectifier and PFC: Rectifies mains and corrects power factor. Failed bridges and PFC switches are common.
  3. Bulk capacitors: Electrolytic capacitors age with heat and ripple. Bulging or low capacitance is a frequent cause.
  4. Switching stage: Power switches chop the DC at high frequency. Shorted switches often take the driver with them.
  5. Transformer and output: The transformer isolates and steps the voltage. Output diodes and filter capacitors follow.
  6. Control and feedback: The control IC and feedback loop hold the output steady. Drift here gives wrong or noisy output.
02Types

Types, makers and where they are used

TypeTypical useWhat we do
AC-DC industrial SMPSPanels, PLC and drive controlComponent-level repair, retrofit
DC-DC converterVehicles, telecom, defenceRepair or rebuild
DC-AC inverter and UPSBackup and solarBoard repair, battery retrofit
High-voltage supplyX-ray, test, laser, analysersBoard repair, bench test
Medical equipment supplyImaging and lab equipmentBoard repair, failure analysis
Telecom rectifierTelecom sheltersModule repair
Server and rack supplyData roomsBoard repair
24 V and 28 V defence supplyDefence electronicsBench repair, rebuild obsolete boards
03Faults

Fault symptoms, causes and safe checks

Tap a symptom for the likely causes and the safe checks. Switch off and lock out before touching any wiring.

No output, fuse blown

Likely causes: Shorted bridge, switch or capacitor

Safe checks: Check input fuse, bridge, switch and bulk capacitor

Output low or unstable

Likely causes: Aged output capacitors, feedback drift

Safe checks: Check output ripple, optocoupler and reference

Hiccup or repeated restart

Likely causes: Overload, shorted secondary, faulty control IC

Safe checks: Isolate the load, test the control stage

Overheating or fan noise

Likely causes: Dried capacitors, blocked airflow, weak fan

Safe checks: Check capacitors, fan and heatsink contact

Clicking or buzzing

Likely causes: Failing start-up resistor or control stage

Safe checks: Check start-up circuit and snubber

Output ripple or noise

Likely causes: Output capacitors beyond life

Safe checks: Measure ripple, replace capacitors

04Diagnosis

Diagnosis flow: find the fault in five steps

Diagnosis flowFive steps to find the fault, from the cable to the sensing element.1
Receive the unit and nameplate
2
Visual and input-stage check
3
Bench power-up on a safe supply
4
Fault found and parts replaced
5
Output and protection test

We test on the bench with the output checked against the nameplate. The plant re-validates the unit in its own system.

05Alternatives

Not repairable or not available? Your options

When a industrial power supply cannot be repaired or is no longer sold, there are five routes.

RouteWhat it means here
Repair the originalReplace failed parts at component level and test the unit.
Exchange unitA tested unit from our stock where one is available.
Retrofit replacementA new supply mounted and wired to fit the old position.
Rebuild the boardReverse-engineer an obsolete board and rebuild it.
Source abroadSourcing through our offices and partners abroad.

More on replacement options

06Bulk

Bulk repair and re-export

Equipment makers and service companies can send power supplies in batches. We log each unit, test it, repair it and return it with a test record. Every repair carries a warranty; terms are on the quote.

07FAQ

Frequently asked questions

Which power supplies do you repair?

We repair large industrial AC-DC, DC-DC and DC-AC units, high-voltage supplies, X-ray and laser supplies, medical equipment supplies, telecom rectifiers, server supplies and 24 V and 28 V defence supplies. We do not repair small plug-in adapters.

Can you repair an obsolete power supply?

Often yes. We repair at component level, or reverse-engineer and rebuild the board when parts are no longer sold.

Can you make a replacement for a discontinued unit?

Yes. We build a retrofit unit to match the input, output and mounting of the old one. Send the nameplate and photos.

Do you repair power supplies in bulk?

Yes. We take batches from equipment makers and service companies, test every unit and return a record with each one.

Can foreign companies send power supplies for repair?

Yes. Companies abroad can ship units to Puducherry for repair and return. We can advise on the paperwork.

What do you need to start?

The nameplate, a clear photo of the unit and a short description of the fault. A photo of the board helps.

Is Star an OEM service partner?

No. Star Automations is an independent repair company. Repairs are made at component level on our bench.