When a PLC, HMI or servo family goes obsolete, the risk is not the next failure but the one after it, when no spare is left. We repair the old system to keep you running, then plan and carry out the move to a current platform: audit, program conversion, I/O mapping, panel changes, staged testing and cut-over with a rollback plan.

Control panel and PLC work at the Star Automations bench
01Paths

Common migration paths

From (legacy)To (current)Detail
Siemens S5 (S5-90U to S5-155U)S7-1200 / S7-1500 with TIA PortalSiemens migration
Siemens S7-300, S7-400, Step 7S7-1500, ET 200SP, TIA PortalSiemens migration
Allen-Bradley PLC-5, SLC 500, MicroLogixControlLogix, CompactLogix, Micro800Allen-Bradley migration
Mitsubishi A and QnA series, FX1/FX2/FX3Q, iQ-R, iQ-F (FX5)Mitsubishi migration
Omron C200H, CQM1, CS1, CJ1CJ2, NJ, NX1POmron migration
Modicon Quantum, Premium, TSX MicroM580, M340Planned per site
GE Fanuc 90-30, 90-70PACSystems RX3iPlanned per site
Old HMIs: PanelView, Siemens OP/TP/MP, Pro-face GP, Mitsubishi GOTPanelView 5000, Siemens Comfort and Unified, Pro-face GP4000/ST6000, GOT2000HMI replacement
Servo: Simodrive 611, Kinetix 6000, MR-J2S, Sigma-IISinamics S120, Kinetix 5700, MR-J4/J5, Sigma-7Servo system upgrades
02Method

How a migration runs

  1. Audit

    Hardware, I/O, program, network.

  2. Plan

    Platform, I/O map, panel changes.

  3. Convert

    Program and HMI rebuilt and commented.

  4. Test

    Simulation, then panel test.

  5. Cut-over

    Staged start-up, rollback ready.

03Deliverables

What you get

  • Audit report with the risk of each obsolete part
  • Converted and commented PLC program and HMI screens
  • Updated electrical drawings and I/O list
  • Factory test record and site commissioning sheet
  • Training for your maintenance team
  • Spares list for the new system
04Meanwhile

Keeping the old system alive

Until cut-over, we repair PLC, HMI and CNC modules at component level and supply obsolete spares from stock or sourcing.

05FAQ

Questions

Can you keep the old system running until the migration?

Yes. We repair the legacy PLC, HMI and drive modules and source obsolete spares, so the machine keeps running while the new system is prepared.

Do you need our original program?

A backup helps a lot. If there is none, we upload what is in the PLC and document it before conversion.

How long is the shutdown?

Most of the work is done before cut-over: program conversion, panel building and testing. The shutdown is planned for the shortest window the plant can give, with a rollback plan.

Do you migrate HMIs without changing the PLC?

Yes. An HMI can often be replaced on its own when the old panel fails and spares are gone.