X-ray generator and high-voltage power supply board repair

Star Automations repairs high-voltage generator and control boards from industrial X-ray systems, NDT equipment and baggage scanners, and industrial high-voltage supplies used in packaging and inspection lines. Boards are removed from the system and sent to our bench in Puducherry, Chennai or Bengaluru for component-level repair, a powered functional test and a written test report.

Scope: component-level bench repair of HV generator and control boards removed from the system and sent to us by the equipment owner's service agency; installation and system testing remain with the customer's own qualified engineer.

What we repair

We work at component level on the electronics that drive and control the high voltage. We do not just swap modules.

From industrial X-ray, NDT and baggage scanners

  • HV generator boards and their power stages
  • Inverter and IGBT/MOSFET driver boards
  • Filament supply and filament control boards
  • Generator control and logic boards
  • Low-voltage supply and SMPS boards inside the generator

From packaging and inspection lines

  • Industrial high-voltage power supplies and HV modules
  • The control and driver boards around them

Star has repaired industrial high-voltage generators, including units used in industrial packaging machines, as part of its 25+ years of industrial electronics repair.

How a repair job works

  1. Send details. WhatsApp a photo of the board, the part number from its label, and the fault or error code seen on the system.
  2. Remove and send the board. Your service engineer removes the board from the system and couriers it to our bench, or hands it in at Puducherry, Chennai or Bengaluru.
  3. Bench diagnosis. We inspect the board, trace the fault to component level, and send you a quote.
  4. Repair on your go-ahead. We replace failed components using parts that pass our incoming QC.
  5. Bench test. Each repaired board gets component-level checks and a powered functional test of the low-voltage control, drive and protection circuits on our bench, with a written test report.
  6. Return and refit. The board comes back with the test report. Your engineer refits it, and final kV/mA verification is done on the system by your engineer.

What we test, and what stays with your engineer

On our bench

  • Component-level checks: semiconductors, capacitors, resistors, magnetics and connectors, with IC testing, LCR measurement and fault location
  • Powered functional test of the low-voltage control, drive and protection circuits
  • Driver and control waveforms checked on oscilloscopes
  • Insulation check (hipot, Chroma tester) on isolated parts only, as an insulation check, not an output test
  • Load testing of low-voltage supply sections on an electronic load
  • A written test report for every board

With your engineer, on the system

  • Refitting the board and system integration
  • Final kV/mA verification on the system
  • Installation and system testing, including any radiation-related checks and records

What we do not do

  • Star does not do insert or vacuum rebuild in-house.
  • We do not work on X-ray tubes or tube housings.
  • We do not service baggage scanners on site. For scanners, we repair boards only.
  • We do not service medical or radiotherapy X-ray systems.
  • We do not repair interlock, protection or other radiation-safety boards.
  • We do not do installation, system commissioning or radiation testing.

Who this is for

  • Security-scanner service providers and AMC firms maintaining X-ray baggage and parcel scanners
  • NDT and industrial radiography firms
  • Inspection-machine builders and system integrators
  • Plant maintenance teams running packaging and inspection lines with HV supplies
  • Medical imaging service agencies: we take board-level bench work only from service agencies, who keep all regulatory responsibility for the equipment

Evidence: who we are and how we test

Company facts

  • 25+ years of component-level industrial electronics repair
  • ISO 9001:2015 certified (Puducherry factory; QRO certificate 3050260527171Q, valid to 26 May 2029)
  • 3,000+ customers and 100+ brands repaired
  • Repair benches in Puducherry, Chennai and Bengaluru; offices in Hyderabad and Delhi
  • Every repair carries a warranty; terms are on the quote.

Test and validation equipment on our benches

  • QMAX IC tester
  • Hipot tester (insulation checks on isolated parts)
  • LCR meter
  • Fault locator
  • SMD rework station with IR pre-heater
  • Electronic load tester
  • Oscilloscopes
  • Power meters

What the written test report contains

  • Board description, part number and serial number as received
  • Fault reported and fault found
  • Components replaced, with references
  • Visual and thermal inspection notes
  • Insulation check result on isolated parts (hipot), with the test applied
  • Powered functional test results for the low-voltage control, drive and protection circuits
  • Oscilloscope captures of key driver and control signals
  • Before and after photos
  • Tested by, and date
  • Note: final kV/mA verification is done on the system by your engineer

Frequently asked questions

Do you repair X-ray generators?

Yes. We do component-level bench repair of HV generator and control boards removed from industrial X-ray, NDT and baggage-scanner systems. Your service agency removes the board and sends it to us; installation and system testing remain with your engineer.

How do you prove a repaired board works?

Each repaired board gets component-level checks and a powered functional test of the low-voltage control, drive and protection circuits on our bench, with a written test report; final kV/mA verification is done on the system by your engineer.

Do you repair X-ray tubes?

No. Star does not do insert or vacuum rebuild in-house, and we do not work on tubes or tube housings. We repair the generator and control electronics that drive the tube.

Can you repair baggage scanner boards?

Yes, board repair only. We repair generator, inverter, filament and control boards from X-ray baggage and parcel scanners. We do not service scanners on site.

Do you repair industrial high-voltage power supplies?

Yes. We repair industrial high-voltage power supplies and HV modules from packaging and inspection lines, including their control and driver boards. Star has repaired industrial high-voltage generators used in industrial packaging machines.

What should I send to get a quote?

WhatsApp a clear photo of the board, the part number from its label, the equipment make and model, and the fault or error code. Then courier the board to our bench.

Do you work on medical X-ray or radiotherapy equipment?

We do not service medical or radiotherapy systems. Medical imaging service agencies can send us boards for bench repair; the agency keeps all regulatory responsibility for the equipment.

Is a repaired generator board covered after return?

Every repair carries a warranty; terms are on the quote.

Send us your board

Send a photo of the board and its part number on WhatsApp at +91 97866 22233 or by email to info@starautomations.com. Add the equipment make and model and the fault or error code. We will reply with the next steps for a bench diagnosis.

WhatsApp the board photo and part number