01Anatomy

How a DC-DC converter works and where it fails

A DC-DC converter changes one DC level to another. It switches the input at high frequency, passes it through a transformer or inductor, then rectifies and filters the result. Isolated types keep input and output separate. Star is an independent repair company, not an OEM service partner.

DC-DC converter signal pathSignal path from the sensing element to the drive. Numbers mark the common failure points.DC inputFilter, reverse protection1Switching stageMOSFET, driver2Transformer or inductorMagnetics3Output rectifierDiodes or synchronous FETs4Output filterCapacitors, choke5Control loopPWM IC, feedback6
  1. DC input: Handles surges and reverse connection at the input.
  2. Switching stage: Chops the input. Shorted switches are the most common failure.
  3. Transformer or inductor: Transfers energy. Overheating and shorted turns appear here.
  4. Output rectifier: Rectifies the output and takes the heat of the load.
  5. Output filter: Smooths the output. Aged capacitors raise ripple.
  6. Control loop: Holds the output steady and limits current.
02Types

Types, makers and where they are used

TypeTypical useWhat we do
Isolated DC-DCRailway, defence, telecomRepair or rebuild
Non-isolated buck or boostVehicles, drivesBoard repair
Step-up converterBattery systemsBoard repair, retrofit
Wide-input converterMobile and field equipmentRepair or retrofit
24 V and 28 V suppliesDefence electronicsBench repair, rebuild obsolete boards
03Faults

Fault symptoms, causes and safe checks

Tap a symptom for the likely causes and the safe checks. Switch off and lock out before touching any wiring.

No output

Likely causes: Shorted switch, blown fuse, failed control IC

Safe checks: Check input, switch and driver

Output low under load

Likely causes: Weak output stage, aged capacitors

Safe checks: Check the rectifier and capacitors

Output noisy

Likely causes: Dried output capacitors

Safe checks: Measure ripple and replace capacitors

Gets very hot

Likely causes: Failing switch, poor thermal contact

Safe checks: Check heatsink and switch

Shuts down repeatedly

Likely causes: Protection trip, feedback fault

Safe checks: Test the trip and feedback circuit

04Diagnosis

Diagnosis flow: find the fault in five steps

Diagnosis flowFive steps to find the fault, from the cable to the sensing element.1
Receive the unit and nameplate
2
Visual and input-stage check
3
Bench power-up on a safe supply
4
Fault found and parts replaced
5
Output and protection test

We test on the bench and check the output against the nameplate. The plant re-validates the unit in its own system.

05Alternatives

Not repairable or not available? Your options

When a DC-DC converter cannot be repaired or is no longer sold, there are five routes.

RouteWhat it means here
Repair the originalReplace failed parts at component level and test the unit.
Exchange unitA tested unit from our stock where one is available.
Retrofit replacementA new supply mounted and wired to fit the old position.
Rebuild the boardReverse-engineer an obsolete board and rebuild it.
Source abroadSourcing through our offices and partners abroad.

More on replacement options

06FAQ

Frequently asked questions

Do you repair DC-DC converters?

Yes, large converters used in vehicles, telecom, railway and defence electronics. We repair them at component level and test the output on the bench.

Can you build a replacement for an obsolete DC-DC converter?

Yes. We rebuild the board or build a retrofit unit that matches the input, output and mounting.

Can you repair 24 V and 28 V supplies?

Yes. Our bench handles 24 V and 28 V power supplies. Defence customers are not named on this site.

What do you need from me?

The nameplate, a photo of the unit and the fault. Add the input and output voltages if the label is worn.

Is Star an OEM service partner?

No. Star Automations is an independent repair company.

See also

Star Automations is an independent repair company and not an OEM service partner. Brand names are used only to identify the equipment we repair. The manual for your unit is the authority for exact signals, wiring and settings.