Since 2000 · 3,000+ customers

Home / Large power supply repair / High-voltage power supply

Power supply repair

High-voltage power supply repair and testing in India

Star Automations repairs high-voltage power supplies and HV modules used in analysers, test sets, laser and X-ray equipment. We work at component level in Puducherry, find the failed multiplier, driver or feedback part, and bench-test the output. Send the nameplate and the fault.

01Anatomy

How a high-voltage power supply works and where it fails

A high-voltage supply makes a low-voltage drive, steps it up in a transformer, multiplies it, then measures the output through a divider. Faults gather in the driver, the multiplier and the sensing path. HV units are handled with proper discharge and isolation. Star is an independent repair company, not an OEM service partner.

high-voltage power supply signal pathSignal path from the sensing element to the drive. Numbers mark the common failure points.Low-voltage inputRectifier, filter1Driver stageMOSFET or IGBT2HV transformerStep-up magnetics3MultiplierDiodes and capacitors4Output and dividerHV resistors5Control and protectionReference, trip logic6
  1. Low-voltage input: Takes the mains or DC supply and feeds the driver.
  2. Driver stage: Switches the primary of the HV transformer at high frequency.
  3. HV transformer: Raises the voltage. Turn-to-turn shorts and cracked potting show up here.
  4. Multiplier: Multiplies the voltage. Failed diodes and capacitors cause low or no output.
  5. Output and divider: Divider samples the output for feedback. A drifting divider gives a wrong output.
  6. Control and protection: Sets the output, limits current and trips on arcing.
02Types

Types, makers and where they are used

TypeTypical useWhat we do
Fixed HV moduleAnalysers, detectorsModule repair and test
Programmable HV supplyTest sets, researchBoard repair, calibration check on the bench
HV supply for X-rayImaging, inspectionSee the X-ray page
HV supply for laserLaser equipmentBoard repair and bench test
Bench HV sourceInsulation and hipot testBoard repair
03Faults

Fault symptoms, causes and safe checks

Tap a symptom for the likely causes and the safe checks. Switch off and lock out before touching any wiring.

No output

Likely causes: Failed driver, open transformer, bad multiplier

Safe checks: Check the driver, then the transformer, then the multiplier

Output low

Likely causes: Weak multiplier diodes or capacitors

Safe checks: Test each stage of the multiplier

Output drifts

Likely causes: Aged divider resistors

Safe checks: Check the divider ratio and the feedback

Arcing or crackling

Likely causes: Cracked insulation, dirty HV area

Safe checks: Inspect the HV area and insulation

Trips at once

Likely causes: Faulty protection or shorted output

Safe checks: Isolate the output and test the trip circuit

04Diagnosis

Diagnosis flow: find the fault in five steps

Diagnosis flowFive steps to find the fault, from the cable to the sensing element.1
Receive the unit and nameplate
2
Visual and input-stage check
3
Bench power-up on a safe supply
4
Fault found and parts replaced
5
Output and protection test

We test on the bench and check the output against the nameplate. The plant re-validates the unit in its own system.

05Alternatives

Not repairable or not available? Your options

When a high-voltage power supply cannot be repaired or is no longer sold, there are five routes.

RouteWhat it means here
Repair the originalReplace failed parts at component level and test the unit.
Exchange unitA tested unit from our stock where one is available.
Retrofit replacementA new supply mounted and wired to fit the old position.
Rebuild the boardReverse-engineer an obsolete board and rebuild it.
Source abroadSourcing through our offices and partners abroad.

More on replacement options

06FAQ

Frequently asked questions

Do you repair high-voltage power supplies?

Yes. We repair HV supplies and modules at component level and bench-test the output. This covers analysers, test sets, laser supplies and X-ray related supplies.

Can you repair an old HV module that is no longer sold?

Often yes. If parts are missing we reverse-engineer and rebuild the board, or build a retrofit replacement.

What do I need to send?

The nameplate, a clear photo of the unit and a note on how it failed. Mention the output voltage and current.

Is HV repair safe?

HV units are discharged and handled on an isolated bench. Never open a charged unit yourself; send it as it is.

Is Star an OEM service partner?

No. Star Automations is an independent repair company working at component level.

See also