Power supply repair
Power supply testing and failure analysis in India
Star Automations tests power supplies on the bench and analyses repeat failures at component level. We inspect the unit, find the failed stage, trace the cause and write a test record. Send the unit, the nameplate and a note on when and how it failed.
How a power supply for failure analysis works and where it fails
A repair that fails again wastes money. Failure analysis looks past the failed part to the cause: heat, surge, ageing capacitors, a weak design or a bad load. We report what we find. Star is an independent repair company, not an OEM service partner.
- Inspect: Burn marks, bulging parts and cracked joints are recorded.
- Test stages: Input, switching, output and control are tested one after another.
- Find the part: The failed part is identified and removed.
- Trace the cause: Heat, surge, ageing or load is traced.
- Repair and retest: The unit is repaired and tested again.
- Report: A record lists the fault, the cause and the test result.
Types, makers and where they are used
| Service | What it covers | Result |
|---|---|---|
| Bench test | Output, ripple, protection | Test record |
| Failure analysis | Repeat or unclear failures | Cause report |
| Batch analysis | Many units, one fault | Common cause report |
| Incoming check | Used or surplus units | Pass or fail record |
| Retrofit test | Rebuilt or retrofit units | Test against the nameplate |
Fault symptoms, causes and safe checks
Tap a symptom for the likely causes and the safe checks. Switch off and lock out before touching any wiring.
Fails again after a month
Likely causes: Cause not removed
Safe checks: Trace heat, surge or load
Fails only under load
Likely causes: Aged capacitors
Safe checks: Test under load on the bench
Fails at start-up
Likely causes: Inrush or start-up circuit
Safe checks: Test the start-up stage
Random shutdowns
Likely causes: Protection trips, joints
Safe checks: Test protection and joints
Many units fail alike
Likely causes: Common weak part
Safe checks: Analyse the batch
Diagnosis flow: find the fault in five steps
We test on the bench and check the output against the nameplate. The plant re-validates the unit in its own system.
Not repairable or not available? Your options
When a power supply for failure analysis cannot be repaired or is no longer sold, there are five routes.
| Route | What it means here |
|---|---|
| Repair the original | Replace failed parts at component level and test the unit. |
| Exchange unit | A tested unit from our stock where one is available. |
| Retrofit replacement | A new supply mounted and wired to fit the old position. |
| Rebuild the board | Reverse-engineer an obsolete board and rebuild it. |
| Source abroad | Sourcing through our offices and partners abroad. |
Frequently asked questions
Do you test power supplies?
Yes. We test the output, ripple and protection on the bench and give a record.
Do you do failure analysis?
Yes. We trace repeat failures to a cause and report it.
Can you analyse a batch?
Yes. We group faults across the batch and report the common cause.
What should I send?
The unit, the nameplate and a note on when and how it failed.
Is Star an OEM service partner?
No. Star Automations is an independent repair company.
See also
- Large power supply repair overview
- SMPS and industrial power supply repair
- X-ray generator and high-voltage repair
- Modification and alternatives
- Bulk power supply repair
- Obsolete spares
Star Automations is an independent repair company and not an OEM service partner. Brand names are used only to identify the equipment we repair. The manual for your unit is the authority for exact signals, wiring and settings.