Power supply repair, testing and alternatives
Large power supply repair, testing and alternatives in India
Star Automations is an independent repair company in Puducherry. We repair, test, analyse and rebuild large industrial, high-voltage, medical, telecom, server and defence power supplies, and build retrofit alternatives for obsolete units. Send the nameplate and a photo of the fault.
How a industrial power supply works and where it fails
Every power supply, from a 24 V industrial unit to a high-voltage generator, follows the same path: mains in, rectify, store, switch, transform, regulate. Faults cluster at a few points on that path. Star is an independent repair company, not an OEM service partner.
- Input stage: Fuse, EMI filter, varistor and inrush limiter take the first hit from surges.
- Rectifier and PFC: Rectifies mains and corrects power factor. Failed bridges and PFC switches are common.
- Bulk capacitors: Electrolytic capacitors age with heat and ripple. Bulging or low capacitance is a frequent cause.
- Switching stage: Power switches chop the DC at high frequency. Shorted switches often take the driver with them.
- Transformer and output: The transformer isolates and steps the voltage. Output diodes and filter capacitors follow.
- Control and feedback: The control IC and feedback loop hold the output steady. Drift here gives wrong or noisy output.
Types, makers and where they are used
| Type | Typical use | What we do |
|---|---|---|
| AC-DC industrial SMPS | Panels, PLC and drive control | Component-level repair, retrofit |
| DC-DC converter | Vehicles, telecom, defence | Repair or rebuild |
| DC-AC inverter and UPS | Backup and solar | Board repair, battery retrofit |
| High-voltage supply | X-ray, test, laser, analysers | Board repair, bench test |
| Medical equipment supply | Imaging and lab equipment | Board repair, failure analysis |
| Telecom rectifier | Telecom shelters | Module repair |
| Server and rack supply | Data rooms | Board repair |
| 24 V and 28 V defence supply | Defence electronics | Bench repair, rebuild obsolete boards |
Fault symptoms, causes and safe checks
Tap a symptom for the likely causes and the safe checks. Switch off and lock out before touching any wiring.
No output, fuse blown
Likely causes: Shorted bridge, switch or capacitor
Safe checks: Check input fuse, bridge, switch and bulk capacitor
Output low or unstable
Likely causes: Aged output capacitors, feedback drift
Safe checks: Check output ripple, optocoupler and reference
Hiccup or repeated restart
Likely causes: Overload, shorted secondary, faulty control IC
Safe checks: Isolate the load, test the control stage
Overheating or fan noise
Likely causes: Dried capacitors, blocked airflow, weak fan
Safe checks: Check capacitors, fan and heatsink contact
Clicking or buzzing
Likely causes: Failing start-up resistor or control stage
Safe checks: Check start-up circuit and snubber
Output ripple or noise
Likely causes: Output capacitors beyond life
Safe checks: Measure ripple, replace capacitors
Diagnosis flow: find the fault in five steps
We test on the bench with the output checked against the nameplate. The plant re-validates the unit in its own system.
Not repairable or not available? Your options
When a industrial power supply cannot be repaired or is no longer sold, there are five routes.
| Route | What it means here |
|---|---|
| Repair the original | Replace failed parts at component level and test the unit. |
| Exchange unit | A tested unit from our stock where one is available. |
| Retrofit replacement | A new supply mounted and wired to fit the old position. |
| Rebuild the board | Reverse-engineer an obsolete board and rebuild it. |
| Source abroad | Sourcing through our offices and partners abroad. |
Bulk repair and re-export
Equipment makers and service companies can send power supplies in batches. We log each unit, test it, repair it and return it with a test record. Every repair carries a warranty; terms are on the quote.
EV charger repair
Projector, cinema and broadcast equipment repair
Frequently asked questions
Which power supplies do you repair?
We repair large industrial AC-DC, DC-DC and DC-AC units, high-voltage supplies, X-ray and laser supplies, medical equipment supplies, telecom rectifiers, server supplies and 24 V and 28 V defence supplies. We do not repair small plug-in adapters.
Can you repair an obsolete power supply?
Often yes. We repair at component level, or reverse-engineer and rebuild the board when parts are no longer sold.
Can you make a replacement for a discontinued unit?
Yes. We build a retrofit unit to match the input, output and mounting of the old one. Send the nameplate and photos.
Do you repair power supplies in bulk?
Yes. We take batches from equipment makers and service companies, test every unit and return a record with each one.
Can foreign companies send power supplies for repair?
Yes. Companies abroad can ship units to Puducherry for repair and return. We can advise on the paperwork.
What do you need to start?
The nameplate, a clear photo of the unit and a short description of the fault. A photo of the board helps.
Is Star an OEM service partner?
No. Star Automations is an independent repair company. Repairs are made at component level on our bench.
See also
- High-voltage power supply repair
- DC-DC converter repair
- DC-AC inverter repair
- Medical equipment power supply repair
- Telecom rectifier repair
- Server power supply repair
- Radar and defence power supply repair
- Bulk power supply repair
- Repair and re-export for foreign companies
- Modification and alternatives
- Testing and failure analysis
- SMPS and industrial power supply repair
- X-ray generator and high-voltage repair
- Laser power supply repair
- UPS repair
- Lithium battery and BMS repair
- Obsolete spares
Star Automations is an independent repair company and not an OEM service partner. Brand names are used only to identify the equipment we repair. The manual for your unit is the authority for exact signals, wiring and settings.