Since 2000 · 3,000+ customers

Delta ASDA · Migration guide · Updated November 2026

Delta ASDA-B to ASDA-B2 servo migration guide

Star Automations repairs Delta ASDA-B, ASDA-B2 and ASDA-A2 servo drives and ECMA motors from Puducherry for customers across India. This guide matches each ASD-B drive to its ASD-B2 equivalent by power rating and lists what to verify first: CN1 wiring, motor encoder and parameters.

ASDA-B to ASDA-B2 drive pairing

Pairings follow the Delta ASDA-B user manual and the ASDA-B2 catalog. They match by power rating and motor frame. Always confirm against the motor nameplate.

RatingASDA-B driveASDA-B2 driveMatching ECMA motors
100 WASD-B0121-AASD-B2-0121-BECMA-C▲0401S
200 WASD-B0221-AASD-B2-0221-BECMA-C▲0602S
400 WASD-B0421-AASD-B2-0421-BECMA-C▲0604S, ECMA-C▲08047
750 WASD-B0721-AASD-B2-0721-BECMA-C▲0807S
1 kWASD-B1021-AASD-B2-1021-BECMA-C▲1010S
1.5 kWASD-B1521-AASD-B2-1521-BECMA-E▲1315S
2 kWASD-B2023-AASD-B2-2023-BECMA-C▲1020S, ECMA-E▲1320S

The ▲ in an ECMA model number is the encoder digit. In the ASDA-B2 catalog, 1 means 20-bit incremental and 2 means 17-bit incremental.

What differs between the two series

ItemASDA-B (Delta manual)ASDA-B2 (Delta manual)
CN1 I/O connector25-pin44-pin
CN2 encoder connector9-pin9-pin
Motor encoderIncremental, 2,500 PPR (10,000 PPR after ×4)Incremental 17-bit or 20-bit; magnetic 13-bit option

On the ASDA-B2 the default position loop gain P2-00 is 35 rad/s and the speed loop gain P2-04 is 500 rad/s. Because CN1 has a different pin count, the I/O wiring from the PLC or controller must be re-checked, not just re-plugged. The same applies to parameters: P1-00 selects the pulse command type (quadrature, CW and CCW pulse, or pulse and direction) and P1-01 selects the control mode on both series.

Migration checklist

  1. Note the drive, motor and encoder model numbers from the nameplates.
  2. Record every parameter from the old drive before removal.
  3. Match the new drive by rating and check the supply: ASD-B2-2023-B and 3023-B are three-phase only.
  4. Re-wire CN1 to the 44-pin layout and check CN2 encoder cabling.
  5. Set P1-00, P1-01, the electronic gear ratio (P1-44 and P1-45) and the gains, then test a slow move before running the machine.

If you only need the old drive running again, send it for repair instead. We test the drive, motor and encoder on our bench and return them with a printed test report.

Delta ASDA-B migration FAQ

Is the Delta ASDA-B2 a drop-in replacement for the ASDA-B?

Not automatically. The ASDA-B manual lists a 25-pin CN1 and a 2,500 PPR incremental motor encoder, while the ASDA-B2 manual lists a 44-pin CN1 and 17-bit or 20-bit incremental encoders. Check the CN1 wiring, motor encoder and parameters before you change drives.

Which ASDA-B2 drive matches the ASD-B0421-A?

By power rating, the ASD-B2-0421-B (400 W). Both Delta manuals pair the 400 W drive with the ECMA-C▲0604S and similar 60 and 80 mm flange motors. Confirm the motor model on the nameplate.

Can I connect an old ASDA-B motor to an ASDA-B2 drive?

The Delta B2 catalog states the ASDA-B series shares power and encoder cables with the B2. Motor encoder type still decides compatibility, so send us the motor nameplate and we will confirm before you order.

Which parameters do I check first after changing to an ASDA-B2?

Start with P1-00 (external pulse input type), P1-01 (control mode), P1-44 and P1-45 (electronic gear ratio) and the P2-00 and P2-04 gains. Parameter values do not copy across automatically.

Do you repair the old ASDA-B drives and ECMA motors?

Yes. We repair Delta ASDA-B, ASDA-B2 and ASDA-A2 servo drives and ECMA servo motors on our bench. Star Automations is an independent repair centre, not an OEM service partner.

Send the drive and motor model

Every repair carries a warranty; terms are on the quote. Delta and ASDA are trademarks of their owners.