Alarm guide · Delta ASDA-B2 · Updated November 2026
Delta AL009 alarm: Excessive position deviation
Delta ASDA-B2 alarm AL009 means the position error between command and feedback grew beyond the limit set in parameter P2-35. The manual lists a small P2-35 value, low gain, a low torque limit and excessive external load as causes.
Likely causes
- Parameter P2-35 is set too small.
- Position loop gain is set too low.
- The torque limit is set too low.
- The external load on the motor is excessive.
First checks
- Check P2-35 and raise it if it is set too small for the application.
- Review the gain settings and adjust them for the load.
- Check the torque limit setting and the torque-limit digital input.
- Turn the shaft by hand with the drive off; a binding mechanism or heavy load points to the machine, not the drive.
- Reduce the external load or re-evaluate the motor capacity if the load is too high.
These steps follow the corrective actions in the Delta ASDA-B2 user manual. Switch the drive off and wait for the DC bus to discharge before touching any wiring.
When to send it for repair
Send the motor and drive when the mechanism moves without binding, the parameters are correct and AL009 still returns. We test the encoder, windings and drive output on our bench.
See Delta servo drive repair, Delta servo motor repair, Delta ASDA-A2 servo drive and the ASDA-B to ASDA-B2 migration guide.
Delta AL009 FAQ
What does Delta AL009 mean?
AL009 is the excessive deviation of position command alarm. The following error exceeded the value set in P2-35.
Which parameter sets the AL009 limit?
Parameter P2-35 sets the position deviation limit. When the difference is greater than this value, AL009 occurs.
Can a mechanical problem cause AL009?
Yes. A binding axis or heavy external load can stop the motor following the command, so check the mechanism first.
Still showing the alarm? Send it for repair
We test the motor, encoder and drive on our bench and return it with a printed test report. Every repair carries a warranty; terms are on the quote. Star Automations is an independent repair centre, not an OEM service partner.