Delta AL022 alarm: Main circuit power lack phase

Delta ASDA-B2 alarm AL022 means the main circuit power has lost a phase. The manual lists abnormal main circuit power and a loose or unconnected RST cable as causes. It also occurs when only one phase is supplied to the main circuit.

Likely causes

  • The main circuit power is abnormal.
  • An R, S or T cable is loose or not connected.
  • Only one phase is supplied to the main circuit.

First checks

  1. Measure all three phases at the drive main circuit terminals.
  2. Tighten the R, S and T terminals and check the supply fuses or breaker.
  3. Confirm the drive is actually connected to the power source.
  4. Power cycle and see whether the alarm returns; if it persists with a good three-phase supply, the drive needs bench testing.

These steps follow the corrective actions in the Delta ASDA-B2 user manual. Switch the drive off and wait for the DC bus to discharge before touching any wiring.

When to send it for repair

Send the drive when all three phases measure correct and AL022 stays. Include the model number and nameplate details.

See Delta servo drive repair, Delta servo motor repair, Delta ASDA-A2 servo drive and the ASDA-B to ASDA-B2 migration guide.

Delta AL022 FAQ

What does Delta AL022 mean?

AL022 is the main circuit power lack phase alarm. One phase of the main supply is missing.

Can a single-phase supply trigger AL022?

Yes, when the drive is wired for three-phase input. Only some models accept single-phase input, so check the model first.

Is AL022 a drive fault?

Usually the supply, fuses or terminals are at fault. The drive is repaired when the supply tests correct.