Delta AL014 alarm: Reverse limit error

Delta ASDA-B2 alarm AL014 is the reverse limit error. The reverse limit switch has been activated, or the servo system is unstable. Check the limit switch, its wiring and the axis position before changing any parameter.

Likely causes

  • The reverse limit switch is activated by the axis position.
  • The servo system is unstable.

First checks

  1. Move the axis away from the reverse limit and confirm the switch releases.
  2. Check the limit switch contact type and the wiring to the digital input.
  3. If the axis overshoots into the limit, re-adjust the parameters or re-evaluate the motor capacity.
  4. Clear the alarm and test a slow move in the forward direction.

These steps follow the corrective actions in the Delta ASDA-B2 user manual. Switch the drive off and wait for the DC bus to discharge before touching any wiring.

When to send it for repair

Send the drive when the switch and wiring test correct, the axis is clear of the limit and AL014 still appears.

See Delta servo drive repair, Delta servo motor repair, Delta ASDA-A2 servo drive and the ASDA-B to ASDA-B2 migration guide.

Delta AL014 FAQ

What does Delta AL014 mean?

AL014 is the reverse limit error. The reverse limit input is active.

How is AL014 different from AL015?

AL014 is the reverse limit and AL015 is the forward limit. Both use the same checks on the matching switch.

Can an unstable servo cause AL014?

Yes. The manual lists an unstable servo system as a cause, so review the gain settings if the axis overshoots.

Still showing the alarm? Send it for repair

We test the motor, encoder and drive on our bench and return it with a printed test report. Every repair carries a warranty; terms are on the quote. Star Automations is an independent repair centre, not an OEM service partner.