Allen-Bradley · Servo drive repair · India
Allen-Bradley servo drive repair in India
We repair Allen-Bradley (Rockwell) Kinetix and Ultra servo drives at component level: power stage, DC link, feedback input, control and I/O faults. Every repaired drive is tested with a servo motor under load before dispatch and returned with a printed test report. Send the drive label and the fault number, such as a feedback or overcurrent fault, to get a quote. Repair warranty is 3 months to 1 year, stated on each quotation.

Allen-Bradley (Rockwell) servo drives we repair
Send the full catalogue number from the label, for example 2094-BC01-M01-S. If your model is not listed, ask us on WhatsApp.
- Kinetix 6000, 6200 and 6500 drives (2094)
- Kinetix 5500 and 5700 drives (2198)
- Kinetix 350 and 300 drives (2097)
- Kinetix 2000 and earlier Kinetix drives (2093)
- Ultra 3000 drives (2098)
- Matching motors: MPL, MPM, MPF, MPS, VPL, TLY, TLP and 1326AB. For PowerFlex AC drives see VFD repair.


Common Allen-Bradley drive faults
A drive alarm tells you where to look, not always what failed. Overcurrent can be the power stage, the gate drive, the motor or the cable.
- No power, or a failed power stage
- DC bus and precharge faults
- Overcurrent and ground-fault trips
- Feedback faults on MPL, MPM and VPL motors
- Control board and power supply faults
- Cooling fan and overtemperature faults
Allen-Bradley alarm codes and what to check
Kinetix drives show a fault code on the display or in Studio 5000. Send the exact code shown, with the drive catalogue number.
Overcurrent faults
Can be the power stage, the motor or the cable. Disconnect the motor and see if the fault stays.
Bus voltage faults
Check the supply, the shunt or regeneration path and the DC bus.
Feedback faults
Often the encoder, its cable or connector. See the Kinetix S45 feedback fault guide.
Overtemperature faults
Check the fan, the airflow and the enclosure temperature.
Alarm guides: Servo encoder alarms · Test a servo motor without the drive · Repair or replace?
How a repaired Allen-Bradley drive is tested
After component-level repair, the drive is powered up on a test rig, the power stage and feedback circuits are checked, and the drive is run with a servo motor under load. Your drive comes back with its own settings and serial history, and a printed test report.
If the motor is the real cause, the drive repair alone will not hold. When the alarm points to feedback or overcurrent, send the motor too: see Allen-Bradley servo motor repair and encoder repair. We are an independent multi-brand repair company, not an OEM service centre.
Allen-Bradley servo drive repair turnaround
Emergency: same day
For a stopped line. Send the label photo and alarm code first.
Urgent: 3 days
Once the fault is confirmed on inspection.
Standard: 7 days
Planned repair with the full test and a printed report.
Time depends on the fault and on parts. What affects repair cost.
How to send the drive
You can send a drive from anywhere in India. Talk to us before you courier, so the unit is expected and logged on arrival.
Send the nameplate
WhatsApp a clear photo of the drive label, the alarm or fault code and what the machine was doing when it failed.
We confirm repairability
We tell you whether we can test and repair that model before anything is shipped.
Courier or pickup
Courier the drive, with the motor if the alarm points to feedback or overcurrent, to our Chennai or Puducherry bench.
Inspection and quote
The drive is opened and inspected. You get the findings and a quote before work starts.
Repair, test, dispatch
Repaired at component level, tested with a servo motor under load, then dispatched with a printed test report.
Which Allen-Bradley drive works with which motor?
See the Allen-Bradley motor and drive compatibility chart for MPL, MPM, MPF, MPS, VPL, VPF, TL and 1326AB motors, with Kinetix 6000 to 5700 migration notes.
Allen-Bradley servo drive repair questions
More on the FAQ page.
Do you repair Allen-Bradley servo drives in India?
Yes. We repair Allen-Bradley servo drives and amplifiers at component level, test them with a servo motor under load and return them with a printed test report. Send the label photo and alarm code on WhatsApp and we confirm repairability before you courier.
Are you an Allen-Bradley service centre?
No. Star Automations is an independent multi-brand repair company, not an OEM service centre. The brand name only describes the equipment we repair.
Can you repair the motor and the drive together?
Yes. When the alarm points to feedback or overcurrent we test the drive with the motor, so a motor fault does not bring the alarm back.
What do I send for a quote?
The drive label photo, the alarm code, the motor nameplate and what the machine was doing at the time of failure.
Send the drive label and alarm code. We confirm repairability before you courier.
WhatsApp a photo to +91 97866 22233, or email info@starautomations.com.