Emergency: same day
For a line-down motor, where the fault and parts allow. WhatsApp us before you send it so the bench is kept free.
Since 2000 · 3,000+ customers
Fanuc · Servo amplifier repair · India
When a Fanuc axis drops out, the CNC shows an SV alarm and the amplifier in the cabinet shows a status LED or 7-segment code. Before you order a new module, it is worth knowing whether the fault is in the amplifier, the power supply, the cable, or the servo motor itself.
We are a multi-brand servo motor repair company. Fanuc αi, βi, SVM, SPM and matching α / β series motors are repaired at our Puducherry, Chennai and Bengaluru sites. Star Automations has done this work since 2000. We are an independent multi-brand repair company, not affiliated with Fanuc.
WhatsApp a clear photo of the amplifier nameplate (A06B-…) and the alarm or LED status to +91 97866 22233. We confirm repairability before you courier.
*Where the fault and parts allow. Every repaired unit returns with a printed test report.
Send a photo of the nameplate first. We confirm whether the motor is repairable, and the quote, the same working day.
For a line-down motor, where the fault and parts allow. WhatsApp us before you send it so the bench is kept free.
Repair, encoder alignment and test, counted from the day the motor reaches the bench and the quote is approved.
Full repair, encoder alignment, run test under load and a printed test report.
Send the full A06B part number from the label. If your model is not listed, ask on WhatsApp and we check before you ship.
Matching motors (α, αi, β, βi) and Pulsecoders are repaired on the same bench: see Fanuc servo motor repair.
These are technician cues from the bench, not a copy of the OEM manuals. Always confirm against the manual for your control and amplifier.
| Cue | What it usually means | Motor or amplifier? |
|---|---|---|
| Overcurrent or IPM trip alarm | Short or earth fault on U/V/W, failed power stage, or a bad power cable | Often the motor winding or cable first; the amplifier if it trips with the motor leads off |
| Overheat / heat-sink fan stop | Blocked cabinet airflow, failed fan, sustained overload | Drive and cabinet; check motor load and brake drag too |
| Low voltage / DC link low | Incoming AC, PSM output, bus bars, 24 V control supply | Supply or PSM more often than a single SVM |
| Encoder, serial feedback or Pulsecoder alarms (for example SV0368) | Feedback cable, connector or Pulsecoder | Often the motor encoder, not the amplifier |
| FSSB / fibre link alarm | Fibre between modules or to the CNC | Network or cable |
| No display / not ready | Control board, switch-mode supply, or missing 24 V / main power | Amplifier or supply |
For spindle amplifier codes, see the Fanuc spindle drive alarm list.
After inspection you get a clear quote before any work starts.
Swapping the amplifier is the most common first move, and often the wrong one. These cues point to the servo motor or its Pulsecoder more often than the amplifier:
If the motor is the problem, it can usually be repaired: bearings, brake, seals, Pulsecoder or encoder, and windings where needed, then load-tested on our servo bench. See how to check an AC servo motor, multi-brand servo motor repair, Fanuc servo motor repair and Fanuc Pulsecoder repair.
Related: servo drive and amplifier repair · Fanuc servo drive repair · Servo motor repair Bangalore · Servo motor repair Chennai · Servo motor repair Puducherry
One route for servo motors, encoders and drives. You see the price before any work starts, and the report before the unit leaves our bench.
EmergencySame day*
Urgent3 working days
Standard7 working days
*Where the fault and parts allow. Turnaround counts from when the unit reaches our bench and the quote is approved.
Yes. αiSV, βiSV / βiSVM, SVM, SPM and PSM / αiPS modules are repaired at component level at our Puducherry, Chennai and Bengaluru sites and, where applicable, run with a servo motor under load.
No. Star Automations is an independent multi-brand repair company. The Fanuc name only describes the equipment we repair. We are not an OEM service centre and are not affiliated with Fanuc.
We quote after inspection, not from a photo alone. Simple fan, capacitor or connector jobs can be fast; power-stage and control-board work depends on parts. You approve the quote before repair starts.
A clear nameplate photo with the A06B number, the CNC alarm number and/or the amplifier LED or 7-segment status, and a short note on what the machine was doing when it failed. If the cue points to feedback or overcurrent, send the matching motor nameplate too, or the motor itself.
Overcurrent or IPM trips with the motor connected, Pulsecoder or serial feedback alarms that survive a known-good cable, and overload or following-error trips with mechanical drag usually point to the motor, cable or machine.
Yes. Units are powered on a test rig; where applicable they are run with a servo motor under load and returned with a printed test report.
Repair and testing are done at our Puducherry, Chennai and Bengaluru sites. Units can be couriered from anywhere in India after we confirm repairability on WhatsApp.
Yes. Spindle amplifier modules and the power supply modules that feed the DC link are repaired on the same bench when parts and the fault allow. Send the A06B label and the symptom.
Fanuc, αi, βi and related model names are trademarks of their owner. Star Automations is an independent multi-brand repair company and is not affiliated with Fanuc. Status cues above are practical technician guidance; always confirm against the manual for your exact control and amplifier.
WhatsApp a nameplate photo and the alarm to +91 97866 22233, or email info@starautomations.com.