The αi SPM spindle amplifier shows a number on its display when it detects a fault. This guide lists common alarm numbers with their usual meaning and where to look first: amplifier, motor or cable. Star Automations repairs Fanuc spindle amplifiers and spindle motors and is an independent repairer, not a FANUC authorised service provider.

01Before you start

First checks before any repair

  • Note the number on the amplifier display and the status LEDs, and photograph them.
  • Check the amplifier model (SPM, SPM-HV or other) and the motor model from the nameplates.
  • Check cooling: heat sink, fans, filters and cabinet temperature.
  • Check cables and connectors on the feedback and CNC link for damage or loose pins.
  • Isolate power and wait until the DC link charge indicator is out before opening anything.
02Alarm list

Common αi SPM alarm numbers

No.Usual meaningFirst area to check
01Motor overheatingMotor temperature, cooling fan, load and duty cycle
02Excessive speed deviationLoad, acceleration settings, motor and cable
03DC link fuse blownAmplifier power section; do not just replace the fuse
04Input fuse blownInput power side and amplifier
05Control power supply faultAmplifier control power
07Excessive speedSpeed command, parameters and feedback
08Input voltage too highIncoming supply and power supply module
09Excessive load on main circuitHeat sink cooling, load and amplifier
10Input voltage too lowIncoming supply and power supply module
11DC link overvoltageRegeneration, power supply module, braking
12DC link overcurrentPower module and motor winding insulation
18Program ROM checksum errorAmplifier control board
24Serial transfer data errorCNC link cable, noise and earthing
27Position coder signal disconnectedPosition coder cable and connector
29Short-time overloadLoad, cutting conditions and cooling
31Speed detection signal disconnected, or motor restrainedSpeed feedback cable, motor and mechanical restraint
33Insufficient DC link chargingCharging circuit and power supply module
34Parameter value outside allowed rangeParameters after a board or motor change
36Error counter overflowFeedback, mechanical load and parameters
37Speed detector parameter setting errorSpeed detector parameters
41Position coder one-rotation signal detection failurePosition coder, cable and mounting
42Position coder one-rotation signal not detectedPosition coder, cable and mounting
47Position coder signal abnormalityPosition coder and cable
51DC link undervoltageIncoming supply and power supply module
54Overload currentLoad and amplifier
56Cooling fan errorAmplifier cooling fan

Meanings are summarised from published FANUC alarm lists. Your amplifier series and software version may differ. Confirm in the FANUC αi series amplifier descriptions manual (B-65282EN).

03Fault location

Amplifier, motor or cable?

Feedback alarms (27, 31, 41, 42, 47)

Usually point to the position coder or speed sensor signal. Test the cable and connector first, then the sensor and its mounting.

Power alarms (03, 04, 09, 11, 12, 30, 33)

Usually point to the amplifier power section or incoming supply. Measure supply and check insulation of the motor winding before a second power-up.

Thermal and load alarms (01, 02, 29, 56)

Usually point to cooling, fan, load or duty. Fix the cause before resetting.

Communication and memory (13, 16, 18, 24, 25)

Usually point to the CNC link cable, noise, earthing or the amplifier control board.

04Repair

Fanuc spindle repair at Star Automations

Send the amplifier or spindle motor with the alarm number and nameplate. We test the unit, find the fault, repair it and bench-test before return. See Fanuc servo drive and amplifier repair, CNC spindle motor repair and Fanuc alpha amplifier and power supply spares. Machines in Bengaluru: Fanuc drive repair, Bengaluru.

05FAQ

Fanuc spindle alarm questions

What does a Fanuc spindle amplifier alarm number mean?

The number shown on the αi SPM display identifies the fault the amplifier detected, such as overheating, an overcurrent, a feedback signal problem or a communication error. Confirm the meaning for your exact amplifier series in the FANUC αi series amplifier descriptions manual (B-65282EN).

Does a feedback alarm such as 27, 31 or 41 mean the spindle motor is bad?

Not necessarily. These alarms point to the position coder or speed sensor signal, which can also be lost through the cable, connector or mounting. Test the feedback path before replacing the motor or the amplifier.

Can I clear the alarm and keep running?

Reset only after you have found the cause. Repeated overheating, overload or DC link alarms can damage the amplifier or motor if the cause stays.

Is it safe to open the amplifier after the alarm?

Wait for the DC link charge indicator to go out and measure before touching anything. The DC link stays charged after power-off. If you are unsure, send the amplifier to a qualified repairer.

Do you repair Fanuc αi SPM spindle amplifiers and spindle motors?

Yes. Star Automations repairs Fanuc spindle amplifiers and spindle motors. Send the amplifier model and alarm number on WhatsApp or by email. Star Automations is an independent repairer and is not a FANUC authorised service provider.

Do these alarm numbers apply to other Fanuc amplifiers?

Alarm meanings differ between αi SPM, βi SVPM and older α series amplifiers. Use the manual for your series.

Send the alarm number and amplifier model.

WhatsApp a nameplate photo and the fault to +91 97866 22233, or email info@starautomations.com.