Emergency: same day
For a line-down motor, where the fault and parts allow. WhatsApp us before you send it so the bench is kept free.
Since 2000 · 3,000+ customers
Servo motor repair · Allen-Bradley · Encoder
An encoder or feedback error on an Allen-Bradley servo motor does not always mean a bad encoder. The cause can be the feedback device, the cable, the connector or the drive input. Star Automations tests the motor feedback on its universal servo test bench, repairs or replaces the feedback device, then reprograms and aligns it to the motor before return. Star Automations is an independent repairer and is not a Rockwell Automation authorised service provider.
*Where the fault and parts allow. Every repaired unit returns with a printed test report.
Send a photo of the nameplate first. We confirm whether the motor is repairable, and the quote, the same working day.
For a line-down motor, where the fault and parts allow. WhatsApp us before you send it so the bench is kept free.
Repair, encoder alignment and test, counted from the day the motor reaches the bench and the quote is approved.
Full repair, encoder alignment, run test under load and a printed test report.
The drive cannot read position. The fault can sit in the encoder, the cable, the connector or the drive.
A new feedback device must be set up for the motor and aligned to the rotor. Without it the motor can run rough, trip or lose position.
A cracked connector, a damaged cable in a drag chain or a failing encoder shows up only when the axis moves or warms up.
Contaminated or damaged feedback, bearing play or misalignment can cause position error.
One route for servo motors, encoders and drives. You see the price before any work starts, and the report before the unit leaves our bench.
EmergencySame day*
Urgent3 working days
Standard7 working days
*Where the fault and parts allow. Turnaround counts from when the unit reaches our bench and the quote is approved.
Not always. The cable, connector or drive input can cause the same fault. We test the motor feedback on the bench to place the fault.
Yes. We reprogram and align the feedback device to the motor on our universal servo test bench.
A replaced feedback device has to be aligned to the rotor. If it was fitted without alignment, the motor can run rough or the drive can trip. Send it for alignment.
The motor with its nameplate, a photo of the drive fault text, and the cable if you suspect it.
Yes, see Allen-Bradley Kinetix and Ultra servo drive repair. We can test the motor on its own first.
WhatsApp a nameplate photo and the fault to +91 97866 22233, or email info@starautomations.com.