Yaskawa Sigma-III / Sigma-5
Yaskawa Sigma-III and Sigma-5 servopacks and motors: repair and supply
Updated November 2026
Short answer: Star Automations supplies and repairs Yaskawa Sigma-III SGDS servopacks (SGDS-02A12A, SGDS-04A12A, SGDS-08A12A), SGMAS and SGMSS motors, and Sigma-5 SGDV servopacks with SGMJV and SGMAV motors, including the SGMJV-08A3A. Both series are discontinued; we supply units new, surplus or refurbished on request, subject to availability, and repair existing units with a warranty on every repair.
Sigma-III and Sigma-5 at a glance
- Sigma-III (SGDS servopack, SGMAS / SGMSS / SGMPS motors). In SGDS-04A12A the "12" means a MECHATROLINK-II interface; "01" is analog voltage and pulse train.
- Sigma-5 (SGDV servopack, SGMJV / SGMAV motors): 20-bit encoders. In SGDV-5R5A01A, "01" is analog voltage and pulse train; "11" is MECHATROLINK-II.
- A suffix such as -Y27, -Y2, -Y3 or -YU22 marks a special or machine-builder version. Read the full nameplate before ordering; the base model sets the rating, the suffix can change the shaft, connector or firmware.
Part numbers we supply and repair
We offer every part below for sales and service (repair).
| Part number | Series | Type | Rating | Runs with | Supply | Repair |
|---|---|---|---|---|---|---|
| SGDS-02A12AV27 | Sigma-III | Servopack (listed as written; SGDS-02A12A family) | Confirmed from the nameplate | SGMAS-02A on the base SGDS-02A12A | Yes | Yes |
| SGDS-04A12A | Sigma-III | Servopack, MECHATROLINK-II | 400 W | SGMAS-04A | Yes | Yes |
| SGDS-08A12AY27 | Sigma-III | Servopack, MECHATROLINK-II | 750 W | SGMAS-08A | Yes | Yes |
| SGDS-15A | Sigma-III | Servopack | 1.5 kW | SGMSS-15A | On request | Yes |
| SGMAS-02A2A21-Y2 | Sigma-III | Motor | 200 W | SGDS-02A | Yes | Yes |
| SGMAS-082421-Y2 | Sigma-III | Motor (listed as written; SGMAS series) | Confirmed from the nameplate | Confirmed from the nameplate | Yes | Yes |
| SGMAS-08A2A2C-Y2 | Sigma-III | Motor, with brake | 750 W | SGDS-08A | Yes | Yes |
| SGMSS-15A2A2C-Y3 | Sigma-III | Motor, 17-bit absolute encoder, with brake | 1.5 kW | SGDS-15A | Yes | Yes |
| SGMRS-37A2A-YR11 | Sigma-III family | Robot axis motor (Motoman part 149568-8) | 3.7 kW, 23.6 A, 1,500 rpm | Motoman robot controller | Yes | Yes |
| SGMJV-08A3A-YU22 | Sigma-5 | Motor, medium inertia | 750 W | SGDV-5R5A01A or SGDV-5R5A11A | Yes | Yes |
| SGDV-R90A11A | Sigma-5 | Servopack, MECHATROLINK-II | 100 W | SGMJV-01A, SGMAV-01A | On request | Yes |
| SGDV-5R5A01A / SGDV-5R5A11A | Sigma-5 | Servopack | 750 W | SGMJV-08A | On request | Yes |
Existing detail pages: SGMAS motor repair · SGMJV motor repair · SGMAV motor repair · SGDV-120A21A
Sigma-5 part numbers by power rating
The Sigma-5 sizes buyers search for most. SGDV-xxxA01A is the analog voltage and pulse train interface and SGDV-xxxA11A is MECHATROLINK-II. We offer every part in this table for sales and service (repair). For Sigma-II (SGDM, SGDH) drives and motors from 100 W to 5 kW, see our Sigma-II spares page.
| Rating | Servopack | SGMJV (medium inertia, 3,000 rpm) | SGMAV (low inertia, 3,000 rpm) | SGMGV (medium inertia, 1,500 rpm) |
|---|---|---|---|---|
| 100 W | SGDV-R90A01A / 11A | SGMJV-01A | SGMAV-01A | - |
| 200 W | SGDV-1R6A01A / 11A | SGMJV-02A | SGMAV-02A | - |
| 400 W | SGDV-2R8A01A / 11A | SGMJV-04A | SGMAV-04A | - |
| 750 W | SGDV-5R5A01A / 11A | SGMJV-08A | SGMAV-08A | - |
| 850 W | SGDV-7R6A01A / 11A | - | - | SGMGV-09A |
| 1.3 kW | SGDV-120A01A / 11A | - | - | SGMGV-13A |
| 1.8 kW | SGDV-180A01A / 11A | - | - | SGMGV-20A |
| 2.9 kW | SGDV-200A01A / 11A | - | - | SGMGV-30A |
| 4.4 kW | SGDV-330A01A / 11A | - | - | SGMGV-44A |
Supplied new, surplus or refurbished on request, subject to availability. Confirm the full model from the nameplate.
Which motor runs on which servopack?
From the Yaskawa Sigma-III and Sigma-5 catalogs (200 V):
| Servopack | Motors |
|---|---|
| SGDS-02A | SGMAS-02A |
| SGDS-04A | SGMAS-04A |
| SGDS-08A | SGMAS-08A |
| SGDS-15A | SGMSS-15A |
| SGDV-R90A | SGMJV-01A, SGMAV-01A |
| SGDV-5R5A | SGMJV-08A |
Sigma-II users: the SGDM-08ADA runs SGMAH-08A and SGMPH-08A motors. See Sigma-II SGDM and SGDH spares.
Alarm codes and first checks
Sigma-III and Sigma-5 use the same three-digit alarm style (Sigma-II shows two digits, for example A.C9 for A.C90).
| Fault type | Alarm | Name | First check |
|---|---|---|---|
| Encoder | A.C90 | Encoder communications error | Encoder cable, CN2 connector, noise, cable length |
| Encoder | A.810 | Encoder backup alarm | Absolute encoder battery and cable; encoder setup |
| Encoder mismatch | A.050 | Combination error | Servopack and motor capacity |
| Overcurrent | A.100 | Overcurrent or heat sink overheated | Motor insulation, U, V, W short, power stage |
| Position error | A.d00 | Position error pulse overflow | Binding, brake, gains, Pn520 setting, encoder wiring |
| Control board | A.020, A.bF0 | Parameter checksum, system alarm | Power-cycle; if it repeats, the control board needs repair |
| Power supply | A.400, A.410 | Overvoltage, undervoltage | Supply voltage, regenerative resistor, deceleration |
| Phase loss | A.F10 | Power line open phase | All supply phases, fuses, contactor |
| Overheat | A.7A0 | Heat sink overheated | Ambient up to 55 °C, cooling fan, airflow, load |
| Overload | A.710, A.720 | Overload, instantaneous and continuous | Load, binding, brake, wiring |
| Regeneration | A.300, A.320 | Regeneration error, regenerative overload | Regenerative resistor and its setting |
| Overspeed | A.510 | Overspeed | Encoder, motor phase order, gains |
Yaskawa alarm guides: A.100 · A.300 · A.400 · A.710 · A.810 · A.C90 · A.d00
How do you troubleshoot a Sigma-III or Sigma-5 alarm?
- Record the alarm and the alarm history (Fn000) before resetting.
- Measure the supply on the main and control terminals; A.F10 and A.410 often come from a lost phase or a weak supply.
- Disconnect U, V, W and megger the motor. If A.100 persists with the motor disconnected, the servopack is suspect.
- Check the encoder cable and CN2 connector; swap in a known good cable.
- Check the MECHATROLINK-II link on "12" and "11" types: terminator, station address and cable.
- Check mechanics and brake before chasing A.710, A.720 or A.d00.
- Send the unit for test if the alarm returns. We test on a matching motor and on our universal servo test system.
Frequently asked questions
Are Yaskawa Sigma-III SGDS servopacks still available?
Which motor goes with the SGDS-08A12A?
What does a suffix such as Y27 or V27 on an SGDS servopack mean?
Which servopack runs the SGMJV-08A3A?
Can you repair the SGMRS-37A2A-YR11 robot motor?
What does A.7A0 mean?
Do you supply these parts as well as repair them?
Send the nameplate for a quote
Share the full model number and a clear nameplate photo. We reply with what we can supply and what a repair involves.
Supplied new, surplus or refurbished on request, subject to availability.
- WhatsApp: +91 97866 22233
- Email: star@starautomations.com or admin@starautomations.com
- Form: /contact/
Every repair carries a warranty; terms are on the quote. Service locations: Puducherry, Chennai, Bengaluru, Hyderabad and Delhi.
ISO 9001:2015 · 3,000+ customers · 100+ brands · GeM vendor · universal servo test system.
Brand names and part numbers are trademarks of their owners and are used only to identify compatible products; Star Automations is an independent supplier and repair provider.