We repair Yaskawa SERVOPACK servo drives and amplifiers (Sigma-7, Sigma-V, Sigma-II and older) at component level: power stage, DC bus, feedback input, control and I/O faults. Every repaired drive is tested with a servo motor under load before dispatch and returned with a printed test report. Send the drive label and the alarm code, such as A.100 or A.C90, to get a quote. Repair warranty is 3 months to 1 year, stated on each quotation.

Yaskawa SGDV-120A21A servo drive
  • 25+years of servo repair, since 2000
  • 3,000+customers across India
  • 100+servo brands covered by our universal servo motor test equipment
  • 5sites: Puducherry, Chennai, Bengaluru, Hyderabad, Delhi
  • Same dayemergency repair option*

*Where the fault and parts allow. Every repaired unit returns with a printed test report.

Repair turnaround you can plan around

Send a photo of the nameplate first. We confirm whether the motor is repairable, and the quote, the same working day.

Emergency: same day

For a line-down motor, where the fault and parts allow. WhatsApp us before you send it so the bench is kept free.

Urgent: 3 working days

Repair, encoder alignment and test, counted from the day the motor reaches the bench and the quote is approved.

Standard: 7 working days

Full repair, encoder alignment, run test under load and a printed test report.

  • Free repairability check from a nameplate photo
  • Printed test report with every motor
  • Written warranty, terms stated on every quotation
  • Pickup can be arranged; parts that must be imported are quoted with their own timeline
01Models

Yaskawa servo drives and amplifiers we repair

Send the full model number from the label, for example SGD7S-2R8A00A002.

  • Sigma-7 drives (SGD7S, SGD7W)
  • Sigma-V drives (SGDV)
  • Sigma-II drives (SGDM, SGDH)
  • Sigma-I and older drives (SGDA, SGDB, SGDS)
  • Matching motors: SGM7J, SGM7A, SGM7G, SGMJV, SGMAV, SGMGV and older SGM series
Yaskawa SGDV-120A21A servo drive, top view
SGDV-120A21A, top view
Yaskawa SGDM-50ADA-V servo drive
SGDM-50ADA-V
Yaskawa SGDM-75ADA servo drive
SGDM-75ADA
Yaskawa SGDM-1EADA servo drive
SGDM-1EADA
02Failure modes

Common Yaskawa drive faults

A drive alarm tells you where to look, not always what failed. Overcurrent can be the power stage, the gate drive, the motor or the cable.

  • No power, or a blown IGBT or IPM power stage
  • DC bus, overvoltage and regeneration faults
  • Overcurrent alarms such as A.100
  • Encoder communication alarms such as A.C90
  • Switch-mode power supply and gate drive failures
  • Display, keypad and parameter memory faults
03Alarm codes

Yaskawa alarm codes and what to check

Code meanings differ between series. Always confirm against the manual for your exact model.

A.100: overcurrent

Can be the drive power stage, the motor or the cable. Disconnect the motor and see if the alarm stays.

A.C90: encoder communication

Check the encoder cable and connector first, then test the encoder.

A.810: encoder backup

Absolute encoder battery or backup data. Check the battery before replacing parts.

A.300 and A.400: regeneration and overvoltage

Check the regeneration resistor and the supply voltage.

Alarm guides: Yaskawa A.100 overcurrent · Yaskawa A.C90 encoder · Yaskawa A.810 backup · Yaskawa A.300 · Yaskawa A.710

+By series

Yaskawa servo alarm list by series: SERVOPACK codes

Sigma-V and Sigma-7 SERVOPACKs (SGDV, SGD7S, SGD7W) show three-character codes such as A.100 or A.C90. Sigma-II SERVOPACKs (SGDM, SGDH) show two-character codes such as A.10 or A.C9. Code meanings can differ between series and firmware, so confirm against the manual for your exact model before replacing parts.

What it meansSigma-V / Sigma-7 (SGDV, SGD7S, SGD7W)Sigma-II (SGDM, SGDH)First check
Overcurrent or heat sink overheatA.100A.10Disconnect the motor cable. If the alarm stays with the motor off, suspect the drive power stage. If it clears, check the motor and cable insulation.
Regeneration error / regenerative overloadA.300 / A.320A.30 / A.32Check the regeneration resistor, its wiring and the parameter for resistor capacity.
Overvoltage / undervoltageA.400 / A.410A.40 / A.41Check the incoming supply and the deceleration time. Repeated alarms with normal supply point to the DC bus circuit.
OverspeedA.510A.51Check encoder wiring and the motor phase order (U, V, W).
Overload (instantaneous / continuous)A.710 / A.720A.71 / A.72Check for mechanical binding, a brake not releasing, or an undersized motor.
Absolute encoder backup errorA.810A.81Replace the encoder battery, then reset the absolute encoder.
Encoder communication errorA.C90A.C9Check the encoder cable and connector first, then test the encoder. Swap with a known-good cable if you have one.
Position error overflowA.d00A.d0Check the mechanics and gain settings, then the encoder.

If the alarm keeps coming back after these checks, send the drive, and the motor too when the alarm points to feedback or overcurrent. To test the motor yourself first, see how to check an AC servo motor.

04Verification

How a repaired Yaskawa drive is tested

After component-level repair, the drive is powered up on a test rig, the power stage and feedback circuits are checked, and the drive is run with a servo motor under load. Your drive comes back with its own settings and serial history, and a printed test report.

If the motor is the real cause, the drive repair alone will not hold. When the alarm points to feedback or overcurrent, send the motor too: see Yaskawa servo motor repair and Yaskawa encoder repair. We are an independent multi-brand repair company, not an OEM service centre.

05Turnaround

Yaskawa servo drive repair turnaround

Emergency: same day

For a stopped line. Send the label photo and alarm code first.

Urgent: 3 days

Once the fault is confirmed on inspection.

Standard: 7 days

Planned repair with the full test and a printed report.

Time depends on the fault and on parts. What affects repair cost.

06How to send

How to send the drive

You can send a drive from anywhere in India. Talk to us before you courier, so the unit is expected and logged on arrival.

  1. Send the nameplate

    WhatsApp a clear photo of the drive label, the alarm code and what the machine was doing when it failed.

  2. We confirm repairability

    We tell you whether we can test and repair that model before anything is shipped.

  3. Courier or pickup

    Courier the drive, with the motor if the alarm points to feedback or overcurrent, to any of our three sites in Puducherry, Chennai and Bengaluru, or ask us to arrange pickup.

  4. Inspection and quote

    The drive is opened and inspected. You get the findings and a quote before work starts.

  5. Repair, test, dispatch

    Repaired at component level, tested with a servo motor under load, then dispatched with a printed test report.

Yaskawa Sigma-II SGDM-10ADA servopack: repair

Star Automations is an independent multi-brand repair company, not an OEM service centre. We repair discontinued Yaskawa Sigma-II servopacks such as the SGDM-10ADA (1 kW, 200-230 V) with power-stage and control repair, parameter backup and load testing.

  • SGDM-10ADA Sigma-II 1 kW servopack: power module, DC-link and control board repair.
  • Upgrade path Migration to Sigma-7 with motor and encoder compatibility check.
Can a Yaskawa SGDM-10ADA be repaired?

Yes. We repair and test it on the bench; we can also plan an upgrade to Sigma-7.

Sigma-5 SGDV and Sigma-II SGDM servopacks: repair

Star Automations is an independent multi-brand repair company, not an OEM service centre. We repair Yaskawa Sigma-5 SGDV servopacks such as SGDV-5R5A01A and SGDV-120A01A, and Sigma-II SGDM servopacks such as SGDM-15ADA.

  • SGDV-5R5A01A Sigma-5 servopack: power and control repair.
  • SGDV-120A01A Sigma-5 servopack: power and control repair.
  • SGDM-15ADA Sigma-II servopack: power and control repair.
Where can I find the manual for an SGDV-5R5A01A servopack?

Use the manufacturer manual for the exact order number. If the unit is faulty, send us the label and the fault description and we will advise whether repair, upgrade or migration is the better route.

What does it cost to repair an SGDM-15ADA servopack?

The repair cost depends on the exact order number and the fault found on the bench. Send the order number and a photo of the label on WhatsApp and we reply with a repair quote.

Yaskawa SGDH-15AE servopack: repair

Star Automations is an independent multi-brand repair company, not an OEM service centre. We repair Yaskawa Sigma-II SGDH-15AE (1.5 kW) servopacks and plan upgrade to Sigma-7.

  • SGDH-15AE Servopack power and control repair.
Can an SGDH-15AE be repaired?

Yes. We repair and test it.

→How it works

From nameplate photo to a tested motor in 7 steps

One route for servo motors, encoders and drives. You see the price before any work starts, and the report before the unit leaves our bench.

  1. 1 · Nameplate photoSend it on WhatsApp or the form
  2. 2 · Repairable? QuoteUsually the same working day
  3. 3 · Courier or pickupThe unit reaches our bench
  4. 4 · Bench diagnosisInsulation, windings, brake, encoder
  5. 5 · RepairFailed parts, bearings, seals, brake
  6. 6 · Align and run-testEncoder aligned; no-load and load run
  7. 7 · Report and dispatchPrinted test report with the unit
  8. Line down?Servo Swap ships a tested unit first. How Servo Swap works

EmergencySame day*

Urgent3 working days

Standard7 working days

*Where the fault and parts allow. Turnaround counts from when the unit reaches our bench and the quote is approved.

Yaskawa servo drive repair questions

More on the FAQ page.

Do you repair Yaskawa servo drives in India?

Yes. We repair Yaskawa servo drives and amplifiers at component level, test them with a servo motor under load and return them with a printed test report. Send the label photo and alarm code on WhatsApp and we confirm repairability before you courier.

Are you a Yaskawa service centre?

No. Star Automations is an independent multi-brand repair company, not an OEM service centre. The brand name only describes the equipment we repair.

What does Yaskawa alarm A.C90 mean?

It is an encoder communication alarm. The cause is often the encoder, its cable or a connector, but a drive input fault is also possible. See our A.C90 guide.

Can you repair the motor and the drive together?

Yes. When the alarm points to feedback or overcurrent we test the drive with the motor, so a motor fault does not bring the alarm back.

What do I send for a quote?

The drive label photo, the alarm code, the motor nameplate and what the machine was doing at the time of failure.

What is the difference between A.C90 and A.C9?

Both are encoder communication alarms. A.C90 is the code on Sigma-V and Sigma-7 drives; A.C9 is the code on Sigma-II drives (SGDM, SGDH). The cause is often the encoder, its cable or a connector, but a drive feedback input fault is also possible.

What does alarm A.100 (or A.10) mean?

Overcurrent or heat sink overheat. Disconnect the motor and see if the alarm stays. If it stays, the drive power stage is the likely cause.

Can you repair an obsolete Sigma-II or Sigma-I drive?

Yes, in most cases. We repair the unit at component level, so the drive does not need to be in current production.

Send the drive label and alarm code. We confirm repairability before you courier.

WhatsApp a photo to +91 97866 22233, or email info@starautomations.com.