Star Automations repairs Sanyo Denki drives, including SANMOTION R, PY, in India. We read the fault code, repair the drive, check motor feedback on Mitchell test systems, and arrange a retrofit, exchange or alternative when the drive is obsolete. Send the nameplate and the code.

  • 26years of servo repair, since 2000
  • 3,000+customers across India
  • 100+servo brands covered by our universal servo motor test equipment
  • 5sites: Puducherry, Chennai, Bengaluru, Hyderabad, Delhi

Every repaired unit returns with a printed test report.

How a repair starts

Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment.

Every repaired unit is tested on our bench and returns with a printed test report. Timing depends on the fault and the parts, and is stated on the quote.

  • Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment
  • Printed test report with every motor
  • Every repair carries a warranty; terms are on the quote.
  • Pickup can be arranged; parts that must be imported are quoted with their own timeline
01At a glance

How a Sanyo Denki drive works and where it fails

Every servo drive and inverter, including Sanyo Denki, turns mains AC into DC, stores it in the DC bus, and chops it with IGBTs to drive the motor, while the control board reads the feedback device. Faults show up at seven points. Match the numbered point in the picture to the sections below.

Servo drive anatomy and common failure pointsMains supply, rectifier, DC bus capacitors, IGBT inverter and motor, with the control board, feedback loop and braking resistor. Numbers mark the common failure points.AC mainsRectifierAC to DCDC buscapacitorsIGBT inverterpower stageMotorwinding, cableBraking resistorControl board and gate driveCPU, parameters, fieldbusEncoder / resolver1234567
  • 1 Input rectifier and fuses: phase loss, shorted diodes
  • 2 DC-bus capacitors: ageing, under-voltage, ripple
  • 3 IGBT power stage: over-current, short circuit, gate-drive faults
  • 4 Motor and cable: winding or insulation failure, earth fault
  • 5 Encoder or resolver: feedback, mismatch and noise faults
  • 6 Control board: memory, parameter and communication faults
  • 7 Braking chopper and resistor: over-voltage on stopping
02Models

Models and series we repair

Series or modelWhat it isNotes
SANMOTION RServo amplifier familyAlarm codes shown as AL and a number
SANMOTION R 3EServo amplifierSame alarm style as the R series
SANMOTION PYEarlier servo amplifierShows single-character codes such as 1, 5, 8, D
03Error codes

Sanyo Denki error codes and what to do

On the SANMOTION R series the display shows AL and a code. The older PY series shows single characters, for example 1 for over-current, 5 for over-voltage, 8 for a sensor fault and D for excessive deviation. Tap a code for the causes and safe checks.

Over-current, short circuit, earth fault

AL21Power failure (excessive current)

Likely causes: A short in the UVW wiring, a poor motor winding insulation that may only fault at high speed, or an overheated power module. Keep oil and coolant away from the motor and do not run withstand-voltage tests yourself.

Safe checks you can do:

  • With the supply off, locked out and the DC bus discharged as the manual states, disconnect the motor cable from the drive
  • Measure motor and cable insulation to earth with a megger; very low readings (around or below 1 MOhm) point to damaged insulation
  • Inspect the motor terminal box, glands and connectors for water, oil or burn marks
  • Check the load turns freely and lengthen the acceleration ramp if it is too short

Send it to us when: the trip returns with the motor cable disconnected, or the drive trips on power-up or enable.

Encoder, resolver and feedback

AL22Current detection value abnormal

Likely causes: The drive and the motor do not match.

Safe checks you can do:

  • With the supply off, inspect and reseat the feedback connector at the drive and the motor
  • Look for crushed, kinked or cut feedback cable and keep it away from motor power cable
  • Check the feedback type and resolution parameters against the motor nameplate
  • Compare with a known-good motor and cable if you have one

Send it to us when: the cable is good. We check the encoder or resolver on Mitchell TI-5000JX and TI-3000JX test systems and the feedback circuit in the drive.

AL81Encoder phase A and B pulse abnormal

Likely causes: Encoder cable, connector or noise problem.

Safe checks you can do:

  • With the supply off, inspect and reseat the feedback connector at the drive and the motor
  • Look for crushed, kinked or cut feedback cable and keep it away from motor power cable
  • Check the feedback type and resolution parameters against the motor nameplate
  • Compare with a known-good motor and cable if you have one

Send it to us when: the cable is good. We check the encoder or resolver on Mitchell TI-5000JX and TI-3000JX test systems and the feedback circuit in the drive.

AL82Absolute value signal disconnected

Likely causes: Encoder cable disconnected or damaged.

Safe checks you can do:

  • With the supply off, inspect and reseat the feedback connector at the drive and the motor
  • Look for crushed, kinked or cut feedback cable and keep it away from motor power cable
  • Check the feedback type and resolution parameters against the motor nameplate
  • Compare with a known-good motor and cable if you have one

Send it to us when: the cable is good. We check the encoder or resolver on Mitchell TI-5000JX and TI-3000JX test systems and the feedback circuit in the drive.

AL84Encoder to drive communication failure

Likely causes: Cable, connector or encoder fault.

Safe checks you can do:

  • With the supply off, inspect and reseat the feedback connector at the drive and the motor
  • Look for crushed, kinked or cut feedback cable and keep it away from motor power cable
  • Check the feedback type and resolution parameters against the motor nameplate
  • Compare with a known-good motor and cable if you have one

Send it to us when: the cable is good. We check the encoder or resolver on Mitchell TI-5000JX and TI-3000JX test systems and the feedback circuit in the drive.

AL85Encoder initial process error

Likely causes: The encoder is not connected correctly. Connect it properly, then retest.

Safe checks you can do:

  • With the supply off, inspect and reseat the feedback connector at the drive and the motor
  • Look for crushed, kinked or cut feedback cable and keep it away from motor power cable
  • Check the feedback type and resolution parameters against the motor nameplate
  • Compare with a known-good motor and cable if you have one

Send it to us when: the cable is good. We check the encoder or resolver on Mitchell TI-5000JX and TI-3000JX test systems and the feedback circuit in the drive.

Overload, stall and I2t

AL41Overload

Likely causes: Load or settings exceed the drive or motor rating.

Safe checks you can do:

  • With the supply off, turn the motor shaft by hand and check the machine moves freely
  • Check the motor brake releases when enabled
  • Compare the motor current and rating parameters with the nameplate
  • Look for jams or coupling damage

Send it to us when: the mechanics are free and the settings match the nameplate.

Braking resistor and chopper

AL43Regeneration failure

Likely causes: Regenerative power is above the built-in capacity, the load inertia is high or braking time is short, the regeneration resistor is disconnected, or an external resistor impedance is too high. If no external resistor is used, set the drive to use its built-in resistor.

Safe checks you can do:

  • With the supply off and locked out, measure the resistor value
  • Compare the resistance with the minimum in the drive manual
  • Check the wiring and look for heat damage on the resistor
  • Review how often and how hard the machine brakes

Send it to us when: the resistor is good and the fault stays.

Over-temperature

AL51Drive overheated

Likely causes: Abnormal drive temperature. Check the cooling fan and airflow.

Safe checks you can do:

  • Confirm the cooling fan runs and spins freely
  • With the supply off, clean the heatsink and cabinet filters
  • Check clearance around the drive and the ambient temperature
  • Reduce the load or the switching frequency if the manual allows it

Send it to us when: the fan and airflow are good but the drive still overheats.

DC bus over-voltage

AL61Over-voltage

Likely causes: Supply spikes above the rating, or high load inertia raises the DC bus when stopping. Add an external regeneration resistor if none is used, improve the supply, and slow the deceleration.

Safe checks you can do:

  • Lengthen the deceleration ramp
  • Confirm a braking resistor is fitted, wired and of the value the manual requires
  • Measure the supply voltage and look for surges when large loads switch
  • Note whether the trip happens only during stopping

Send it to us when: the trip continues with a good resistor and a long ramp.

Under-voltage and phase loss

AL62Main circuit voltage too low

Likely causes: Supply sag or an internal defect.

Safe checks you can do:

  • Measure all three supply phases under load
  • With the supply off and locked out, check input fuses and terminal tightness
  • Check the input contactor and any upstream breaker
  • Note whether the trip happens at power-up, on enable or during acceleration

Send it to us when: the supply is healthy but the trip persists.

AL63Main power phase loss

Likely causes: One of the R, S or T inputs has no supply.

Safe checks you can do:

  • Measure all three supply phases under load
  • With the supply off and locked out, check input fuses and terminal tightness
  • Check the input contactor and any upstream breaker
  • Note whether the trip happens at power-up, on enable or during acceleration

Send it to us when: the supply is healthy but the trip persists.

Position, speed and following error

ALC1Over-velocity

Likely causes: Speed went above the allowed limit. Check feedback and settings.

Safe checks you can do:

  • Check the coupling and the mechanics for binding
  • Review acceleration, gain and torque limit settings
  • Check the feedback cable and connector
  • Compare commanded and actual position if the drive can log it

Send it to us when: the mechanics and settings are good and the error stays.

ALD1Excessive position deviation

Likely causes: Binding mechanics, aggressive settings, or a feedback fault.

Safe checks you can do:

  • Check the coupling and the mechanics for binding
  • Review acceleration, gain and torque limit settings
  • Check the feedback cable and connector
  • Compare commanded and actual position if the drive can log it

Send it to us when: the mechanics and settings are good and the error stays.

Memory, parameter and internal faults

ALE1EEPROM abnormality

Likely causes: Corrupted parameters, often from a power loss during a parameter write. Do not cut power while writing.

Safe checks you can do:

  • Power cycle the drive after discharge time
  • Restore defaults and reload your backed-up parameters
  • Improve shielding and earthing of control wiring
  • Record the full fault history before resetting

Send it to us when: the fault returns after a reset, which points to hardware.

ALE5Parameter error 1

Likely causes: Parameters are corrupt or out of range.

Safe checks you can do:

  • Power cycle the drive after discharge time
  • Restore defaults and reload your backed-up parameters
  • Improve shielding and earthing of control wiring
  • Record the full fault history before resetting

Send it to us when: the fault returns after a reset, which points to hardware.

Safety first. Only a qualified person should open or measure a drive. Dangerous voltage stays on the DC bus after the supply is switched off. Lock out the supply, wait for the discharge time stated in the manual and confirm the bus is discharged before touching anything.

04Diagnosis

Fault diagnosis in four steps

  1. Read and recordNote the code, the last faults in the history, what the machine was doing and any LEDs or sounds. Take photos of the display and nameplates.
  2. Safe visual checksSupply off, locked out, bus discharged. Look for burn marks, swollen capacitors, dirt, loose terminals, damaged cables and wet connectors.
  3. Isolate the partMotor and cable, feedback, supply or drive? Disconnecting the motor cable and re-testing separates a drive fault from a motor or cable fault.
  4. DecideFixed by a safe check? Back to work. Not fixed? Send the nameplate and code. We repair it or arrange the alternative.
05Self-help

Check these yourself before you send it

  • Power: measure all three phases, check fuses and terminals with the supply locked out
  • Cooling: clean the heatsink and filters, confirm the fan runs
  • Cables: inspect motor power and feedback cables and connectors for damage
  • Settings: compare motor and feedback parameters with the motor nameplate
  • Load: turn the shaft by hand with power off and check the brake releases
  • Backups: save the parameter file and fault history before any reset
  • Prevent repeats: keep the cabinet clean and cool, replace fans on schedule, and keep spare parameters backed up
06Alternatives

Repair or alternative? What to do when the drive is not available

Fault code and nameplate
Safe checks
Send to Star
Inspect and quote
Repair and test
Or: retrofit, exchange, source, remanufacture
OptionWhen it fitsWhat we do
RepairThe drive is repairableWe inspect, repair and check it, then return it. Every repair carries a warranty; terms are on the quote.
ExchangeThe machine cannot waitAsk us about an exchange unit. See the advance exchange page.
Retrofit with an equivalent driveThe model is obsolete or not availableWe match power, feedback type, command interface and fieldbus, then fit a different drive to the same motor.
Motor and drive upgradeBoth parts are old or mismatchedWe propose a matched motor and drive pair and help with parameters.
Source surplus or refurbishedYou want the same modelWe search for the exact part through our sourcing network and partners abroad.
Remanufacture the boardsNo replacement exists in the marketWe rebuild the power or control board. We have reverse engineered and rebuilt obsolete boards.
Parameter recoverySettings are lost or the memory is corruptWe help to rebuild the parameter set from the nameplate and the machine data.

If the drive is no longer sold, match these five things

  • Power and voltage: rated current, supply voltage and overload need
  • Feedback type: encoder, resolver, Hiperface, EnDat, BiSS, absolute or incremental
  • Command interface: analog, pulse and direction, CANopen, EtherCAT, Profibus, Profinet, Modbus
  • Mechanical fit: size, mounting, connectors and cable lengths
  • Safety and braking: safe torque off, brake output and braking resistor

Send these details with the nameplate and we propose a route. A cross-reference is given where one exists. See also advance exchange.

07Testing

How the drive and motor feedback are checked

  • Feedback test: Mitchell Electronics TI-5000JX and TI-3000JX universal servo test systems read the encoder, resolver or sensor signals
  • Waveform check: special encoder test oscilloscope to inspect the feedback signal
  • Fault finding: diagnosis tool, special diagnosis tool and feedback diagnosis tool
  • Inspection and functional check: the unit is checked before it is returned
  • Warranty: every repair carries a warranty; terms are on the quote
→How it works

From nameplate photo to a tested motor in 7 steps

One route for servo motors, encoders and drives. You see the price before any work starts, and the report before the unit leaves our bench.

  1. 1 · Nameplate photoSend it on WhatsApp or the form
  2. 2 · Repairable? QuoteWe assess the nameplate photo and confirm whether the unit is repairable.
  3. 3 · Courier or pickupThe unit reaches our bench
  4. 4 · Bench diagnosisInsulation, windings, brake, encoder
  5. 5 · RepairFailed parts, bearings, seals, brake
  6. 6 · Align and run-testEncoder aligned; no-load and load run
  7. 7 · Report and dispatchPrinted test report with the unit
  8. Line down?Servo Swap ships a tested unit first. How Servo Swap works

Timing depends on the fault and the parts, and is stated on the quote.

09FAQ

Sanyo Denki drive repair FAQ

Do you repair Sanyo Denki drives?

Yes. We repair Sanyo Denki drives and inverters. Send the nameplate, the fault code and a photo of the display, and we confirm the route before you courier anything.

Which Sanyo Denki models and series do you repair?

SANMOTION R series including R 3E, SANMOTION PY series. If your model is not listed, send the nameplate.

My Sanyo Denki drive shows AL21. What does it mean?

Power failure (excessive current). Check the safe steps above first. If the fault returns, send the drive to us.

Can I fix a Sanyo Denki drive fault myself?

You can do the safe checks: supply, fuses, cooling, cables, settings and the load. Do not open the drive or measure inside it unless you are qualified, because the DC bus stays live after switch-off.

What if my Sanyo Denki drive is obsolete or not available?

We repair it, arrange an exchange, retrofit a different drive that matches the power, feedback and command interface, source the same model, or remanufacture the board.

Can you retrofit a different drive to my motor?

Yes, when the power, feedback type, command interface and mounting match. Send the nameplates of the drive and the motor.

Is there a warranty?

Every repair carries a warranty; terms are on the quote.

Are you an OEM service centre?

No. Star Automations is an independent multi-brand repair company and is not an OEM service centre.

Brand names are trademarks of their owners. Star Automations is an independent multi-brand company and is not an OEM service centre. Code lists are general guides; the manual for your exact unit is the authority.

Send the nameplate and the code. We confirm the route first.

WhatsApp a photo of the drive nameplate and display to +91 97866 22233, or email admin@starautomations.com.