Drive repair · Control Techniques
Control Techniques servo drive and inverter repair in India
Star Automations repairs Control Techniques drives, including Unidrive, Digitax, Epsilon, in India. We read the fault code, repair the drive, check motor feedback on Mitchell test systems, and arrange a retrofit, exchange or alternative when the drive is obsolete. Send the nameplate and the code.
- 25+years of servo repair, since 2000
- 3,000+customers across India
- 100+servo brands covered by our universal servo motor test equipment
- 5sites: Puducherry, Chennai, Bengaluru, Hyderabad, Delhi
Every repaired unit returns with a printed test report.
How a repair starts
Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment.
Every repaired unit is tested on our bench and returns with a printed test report. Timing depends on the fault and the parts, and is stated on the quote.
- Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment
- Printed test report with every motor
- Every repair carries a warranty; terms are on the quote.
- Pickup can be arranged; parts that must be imported are quoted with their own timeline
How a Control Techniques drive works and where it fails
Every servo drive and inverter, including Control Techniques, turns mains AC into DC, stores it in the DC bus, and chops it with IGBTs to drive the motor, while the control board reads the feedback device. Faults show up at seven points. Match the numbered point in the picture to the sections below.
- 1 Input rectifier and fuses: phase loss, shorted diodes
- 2 DC-bus capacitors: ageing, under-voltage, ripple
- 3 IGBT power stage: over-current, short circuit, gate-drive faults
- 4 Motor and cable: winding or insulation failure, earth fault
- 5 Encoder or resolver: feedback, mismatch and noise faults
- 6 Control board: memory, parameter and communication faults
- 7 Braking chopper and resistor: over-voltage on stopping
Models and series we repair
| Series or model | What it is | Notes |
|---|---|---|
| Unidrive M (M100, M200, M300, M400, M600, M700, M701) | AC and servo drive family from open-loop to high-performance | Our bench for repaired Control Techniques drives is a Unidrive M701 |
| Unidrive SP | Earlier high-performance AC and servo drive | Predecessor of Unidrive M |
| Digitax HD and Digitax ST | Compact servo drives | Digitax HD is the newer family |
| Epsilon EP | Servo drive for motion control | Used with Unimotor servo motors |
| Commander SK | General-purpose AC drive | Pumps, fans, conveyors |
| Mentor MP | DC drive | Thyristor DC drive |
Control Techniques error codes and what to do
Common Control Techniques fault codes are grouped below. Tap a tile to jump to the group, then tap a code to see the likely causes, the safe checks and when to send the drive to us. Code names differ by model and firmware, so the manual for your exact unit is the authority.
Over-current, short circuit, earth fault
OI.ACOutput instantaneous over-current
Likely causes: Motor or cable short, insulation failure, a ramp that is too short, wrong motor data or an auto-tune that was not run. The drive cannot be reset for about 10 seconds.
Safe checks you can do:
- With the supply off, locked out and the DC bus discharged as the manual states, disconnect the motor cable from the drive
- Measure motor and cable insulation to earth with a megger; very low readings (around or below 1 MOhm) point to damaged insulation
- Inspect the motor terminal box, glands and connectors for water, oil or burn marks
- Check the load turns freely and lengthen the acceleration ramp if it is too short
Send it to us when: the trip returns with the motor cable disconnected, or the drive trips on power-up or enable.
Braking resistor and chopper
OI.BrBraking resistor over-current
Likely causes: The braking resistor is below the drive minimum or shorted, the duty is too high, or the braking IGBT has failed.
Safe checks you can do:
- With the supply off and locked out, measure the resistor value
- Compare the resistance with the minimum in the drive manual
- Check the wiring and look for heat damage on the resistor
- Review how often and how hard the machine brakes
Send it to us when: the resistor is good and the fault stays.
It.brBraking resistor I2t overload
Likely causes: The braking resistor power rating is too small for the braking duty.
Safe checks you can do:
- With the supply off and locked out, measure the resistor value
- Compare the resistance with the minimum in the drive manual
- Check the wiring and look for heat damage on the resistor
- Review how often and how hard the machine brakes
Send it to us when: the resistor is good and the fault stays.
Under-voltage and phase loss
UVDC bus under-voltage
Likely causes: Supply sag, blown input fuse, or a faulty input contactor. Short trips can be transient.
Safe checks you can do:
- Measure all three supply phases under load
- With the supply off and locked out, check input fuses and terminal tightness
- Check the input contactor and any upstream breaker
- Note whether the trip happens at power-up, on enable or during acceleration
Send it to us when: the supply is healthy but the trip persists.
PhInput phase loss
Likely causes: A blown input fuse, loose terminal or an upstream breaker pole. Measure all phase pairs.
Safe checks you can do:
- Measure all three supply phases under load
- With the supply off and locked out, check input fuses and terminal tightness
- Check the input contactor and any upstream breaker
- Note whether the trip happens at power-up, on enable or during acceleration
Send it to us when: the supply is healthy but the trip persists.
Over-temperature
OHt.driveDrive heatsink over-temperature
Likely causes: A failed fan, dirty heatsink, poor enclosure airflow, high ambient temperature, high switching frequency or overload.
Safe checks you can do:
- Confirm the cooling fan runs and spins freely
- With the supply off, clean the heatsink and cabinet filters
- Check clearance around the drive and the ambient temperature
- Reduce the load or the switching frequency if the manual allows it
Send it to us when: the fan and airflow are good but the drive still overheats.
Motor thermistor and temperature sensor
OHt.thMotor thermistor over-temperature
Likely causes: The motor is hot, the motor fan failed, the thermistor wiring is open, or the thermistor type setting is wrong.
Safe checks you can do:
- Confirm the motor is really hot
- Check the motor cooling fan
- With the supply off, check thermistor continuity against the manual
- Check the thermistor type parameter
Send it to us when: the motor is cool and the wiring is good.
Overload, stall and I2t
I.OldMotor current overload (I2t)
Likely causes: Mechanical overload, or the motor rated current parameter does not match the nameplate.
Safe checks you can do:
- With the supply off, turn the motor shaft by hand and check the machine moves freely
- Check the motor brake releases when enabled
- Compare the motor current and rating parameters with the nameplate
- Look for jams or coupling damage
Send it to us when: the mechanics are free and the settings match the nameplate.
Encoder, resolver and feedback
O.SPdMotor over-speed
Likely causes: Encoder feedback wiring or noise, noise on the analog speed reference, or maximum speed settings.
Safe checks you can do:
- With the supply off, inspect and reseat the feedback connector at the drive and the motor
- Look for crushed, kinked or cut feedback cable and keep it away from motor power cable
- Check the feedback type and resolution parameters against the motor nameplate
- Compare with a known-good motor and cable if you have one
Send it to us when: the cable is good. We check the encoder or resolver on Mitchell TI-5000JX and TI-3000JX test systems and the feedback circuit in the drive.
ENC1Encoder channel 1 fault
Likely causes: Damaged encoder cable or connector, or the encoder supply is overloaded.
Safe checks you can do:
- With the supply off, inspect and reseat the feedback connector at the drive and the motor
- Look for crushed, kinked or cut feedback cable and keep it away from motor power cable
- Check the feedback type and resolution parameters against the motor nameplate
- Compare with a known-good motor and cable if you have one
Send it to us when: the cable is good. We check the encoder or resolver on Mitchell TI-5000JX and TI-3000JX test systems and the feedback circuit in the drive.
ENC2Encoder channel 2 fault
Likely causes: A and B signals are bad. Inspect the cable, and check the signals with an oscilloscope.
Safe checks you can do:
- With the supply off, inspect and reseat the feedback connector at the drive and the motor
- Look for crushed, kinked or cut feedback cable and keep it away from motor power cable
- Check the feedback type and resolution parameters against the motor nameplate
- Compare with a known-good motor and cable if you have one
Send it to us when: the cable is good. We check the encoder or resolver on Mitchell TI-5000JX and TI-3000JX test systems and the feedback circuit in the drive.
ENC8Encoder signal loss
Likely causes: Replace the cable or check the encoder.
Safe checks you can do:
- With the supply off, inspect and reseat the feedback connector at the drive and the motor
- Look for crushed, kinked or cut feedback cable and keep it away from motor power cable
- Check the feedback type and resolution parameters against the motor nameplate
- Compare with a known-good motor and cable if you have one
Send it to us when: the cable is good. We check the encoder or resolver on Mitchell TI-5000JX and TI-3000JX test systems and the feedback circuit in the drive.
Memory, parameter and internal faults
HF01 to HF20Internal hardware faults
Likely causes: Power cycle the drive. If HF10 or HF15 appears, disconnect the motor and test again. A persistent hardware fault needs repair.
Safe checks you can do:
- Power cycle the drive after discharge time
- Restore defaults and reload your backed-up parameters
- Improve shielding and earthing of control wiring
- Record the full fault history before resetting
Send it to us when: the fault returns after a reset, which points to hardware.
Communication and fieldbus
SLSerial communication loss
Likely causes: The PLC is not running, the fieldbus cable or termination is bad, or the option module is faulty.
Safe checks you can do:
- Confirm the PLC or controller is running
- Check the cable, connectors and termination
- Check addresses for duplicates
- Check the option module is seated and read its LEDs
Send it to us when: the option card or the drive communication circuit is suspected.
Safety first. Only a qualified person should open or measure a drive. Dangerous voltage stays on the DC bus after the supply is switched off. Lock out the supply, wait for the discharge time stated in the manual and confirm the bus is discharged before touching anything.
Fault diagnosis in four steps
- Read and recordNote the code, the last faults in the history, what the machine was doing and any LEDs or sounds. Take photos of the display and nameplates.
- Safe visual checksSupply off, locked out, bus discharged. Look for burn marks, swollen capacitors, dirt, loose terminals, damaged cables and wet connectors.
- Isolate the partMotor and cable, feedback, supply or drive? Disconnecting the motor cable and re-testing separates a drive fault from a motor or cable fault.
- DecideFixed by a safe check? Back to work. Not fixed? Send the nameplate and code. We repair it or arrange the alternative.
Check these yourself before you send it
- Power: measure all three phases, check fuses and terminals with the supply locked out
- Cooling: clean the heatsink and filters, confirm the fan runs
- Cables: inspect motor power and feedback cables and connectors for damage
- Settings: compare motor and feedback parameters with the motor nameplate
- Load: turn the shaft by hand with power off and check the brake releases
- Backups: save the parameter file and fault history before any reset
- Prevent repeats: keep the cabinet clean and cool, replace fans on schedule, and keep spare parameters backed up
Repair or alternative? What to do when the drive is not available
Unidrive M is the current family that followed Unidrive SP, and Digitax HD followed Digitax ST. Check the manufacturer catalogue for the current range before you order.
| Option | When it fits | What we do |
|---|---|---|
| Repair | The drive is repairable | We inspect, repair and check it, then return it. Every repair carries a warranty; terms are on the quote. |
| Exchange | The machine cannot wait | Ask us about an exchange unit. See the advance exchange page. |
| Retrofit with an equivalent drive | The model is obsolete or not available | We match power, feedback type, command interface and fieldbus, then fit a different drive to the same motor. |
| Motor and drive upgrade | Both parts are old or mismatched | We propose a matched motor and drive pair and help with parameters. |
| Source surplus or refurbished | You want the same model | We search for the exact part through our sourcing network and partners abroad. |
| Remanufacture the boards | No replacement exists in the market | We rebuild the power or control board. We have reverse engineered and rebuilt obsolete boards. |
| Parameter recovery | Settings are lost or the memory is corrupt | We help to rebuild the parameter set from the nameplate and the machine data. |
If the drive is no longer sold, match these five things
- Power and voltage: rated current, supply voltage and overload need
- Feedback type: encoder, resolver, Hiperface, EnDat, BiSS, absolute or incremental
- Command interface: analog, pulse and direction, CANopen, EtherCAT, Profibus, Profinet, Modbus
- Mechanical fit: size, mounting, connectors and cable lengths
- Safety and braking: safe torque off, brake output and braking resistor
Send these details with the nameplate and we propose a route. A cross-reference is given where one exists. See also advance exchange.
How the drive and motor feedback are checked
- Feedback test: Mitchell Electronics TI-5000JX and TI-3000JX universal servo test systems read the encoder, resolver or sensor signals
- Waveform check: special encoder test oscilloscope to inspect the feedback signal
- Fault finding: diagnosis tool, special diagnosis tool and feedback diagnosis tool
- Inspection and functional check: the unit is checked before it is returned
- Warranty: every repair carries a warranty; terms are on the quote
- Dedicated bench: repaired Control Techniques drives are checked on a Unidrive M701 test bench
From nameplate photo to a tested motor in 7 steps
One route for servo motors, encoders and drives. You see the price before any work starts, and the report before the unit leaves our bench.
- 1 · Nameplate photoSend it on WhatsApp or the form
- 2 · Repairable? QuoteWe assess the nameplate photo and confirm whether the unit is repairable.
- 3 · Courier or pickupThe unit reaches our bench
- 4 · Bench diagnosisInsulation, windings, brake, encoder
- 5 · RepairFailed parts, bearings, seals, brake
- 6 · Align and run-testEncoder aligned; no-load and load run
- 7 · Report and dispatchPrinted test report with the unit
- Line down?Servo Swap ships a tested unit first. How Servo Swap works
Timing depends on the fault and the parts, and is stated on the quote.
Control Techniques drive repair FAQ
Do you repair Control Techniques drives?
Yes. We repair Control Techniques drives and inverters. Send the nameplate, the fault code and a photo of the display, and we confirm the route before you courier anything.
Which Control Techniques models and series do you repair?
Unidrive M100 to M700 and M701, Unidrive SP, Digitax HD, Digitax ST, Epsilon EP, Commander SK, Mentor MP. If your model is not listed, send the nameplate.
My Control Techniques drive shows OI.AC. What does it mean?
Output instantaneous over-current. Check the safe steps above first. If the fault returns, send the drive to us.
Can I fix a Control Techniques drive fault myself?
You can do the safe checks: supply, fuses, cooling, cables, settings and the load. Do not open the drive or measure inside it unless you are qualified, because the DC bus stays live after switch-off.
What if my Control Techniques drive is obsolete or not available?
We repair it, arrange an exchange, retrofit a different drive that matches the power, feedback and command interface, source the same model, or remanufacture the board.
Can you retrofit a different drive to my motor?
Yes, when the power, feedback type, command interface and mounting match. Send the nameplates of the drive and the motor.
Is there a warranty?
Every repair carries a warranty; terms are on the quote.
Are you an OEM service centre?
No. Star Automations is an independent multi-brand repair company and is not an OEM service centre.
Brand names are trademarks of their owners. Star Automations is an independent multi-brand company and is not an OEM service centre. Code lists are general guides; the manual for your exact unit is the authority.
Send the nameplate and the code. We confirm the route first.
WhatsApp a photo of the drive nameplate and display to +91 97866 22233, or email admin@starautomations.com.