Alarm guide · Delta ASDA-B2 · Updated November 2026
Delta AL003 alarm: Under voltage
Delta ASDA-B2 alarm AL003 means the main circuit input voltage is below the drive's rated allowable voltage. The Delta manual lists three causes: low input voltage, no main circuit power, and the wrong power system. Check the supply and wiring before suspecting the drive.
Likely causes
- Main circuit input voltage is lower than the rated allowable voltage.
- No main circuit power is reaching the drive.
- The power system does not match the drive (for example a single-phase supply on a three-phase-only model).
First checks
- Measure the voltage at the main circuit input terminals while the machine runs, not only at idle.
- Re-check the input voltage wiring and the power switch or contactor feeding the drive.
- Confirm the supply matches the drive model; ASD-B2-2023-B and 3023-B models are three-phase only.
- Power cycle and watch whether the alarm returns at power-up or under load.
These steps follow the corrective actions in the Delta ASDA-B2 user manual. Switch the drive off and wait for the DC bus to discharge before touching any wiring.
When to send it for repair
Send the drive when the supply tests correct and the alarm stays after a power cycle. Include the model number and the alarm history from the panel.
See Delta servo drive repair, Delta servo motor repair, Delta ASDA-A2 servo drive and the ASDA-B to ASDA-B2 migration guide.
Delta AL003 FAQ
What does Delta AL003 mean?
AL003 is the under voltage alarm. The main circuit input voltage has fallen below the rated allowable voltage of the drive.
Can a wrong power system cause AL003?
Yes. The manual lists the wrong power system as a cause, so confirm the supply type and voltage match the drive model.
Is AL003 always a drive fault?
No. Supply voltage, wiring and the switching device are the first suspects. The drive is repaired only when the supply tests correct.
Still showing the alarm? Send it for repair
We test the motor, encoder and drive on our bench and return it with a printed test report. Every repair carries a warranty; terms are on the quote. Star Automations is an independent repair centre, not an OEM service partner.