Guides · Servo motors
What should you check before changing a servo motor bearing?
Star Automations is best known for multi-brand servo motor repair. The same benches handle a bearing change together with encoder or resolver alignment, then a run test, before the motor goes back into service.
Direct answer: Before changing a servo motor bearing, record the nameplate, drive model, alarm history and the drive's commutation or offset parameter. Photograph the connectors, mark the encoder or resolver housing against the motor body, and check the brake. Leave the feedback device untouched where you can, and re-verify commutation alignment before the motor goes back into service.
On a servo motor, a bearing change is not just mechanical work. The drive needs the encoder or resolver to know where the rotor magnets are. If the feedback device moves against the rotor during the job, the motor can refuse to start, run rough, trip or run away, even with a new bearing and a healthy winding.
Why does a servo motor need alignment after a bearing change?
The drive switches current into the U, V and W windings according to the rotor angle reported by the feedback device. The angle between the feedback zero and the rotor's magnetic pole is the commutation offset (also called phasing or the pole-position offset).
Electrical angle equals mechanical angle multiplied by the number of pole pairs, so a small mechanical slip becomes a large electrical error. That cuts torque, raises current, or can reverse the torque direction.
Bearing work disturbs it when the encoder hub is loosened, the resolver stator is rotated or unclamped, the shaft is hammered, or the phase leads are refitted in a different order.
For the "after" side in detail, see our guide on servo motor not running after a bearing change.
Before you change the bearing: a 10-point checklist
- Record the motor nameplate (model, serial, rated current and speed, feedback type).
- Record the drive model and its alarm history, so you know which faults existed before you started.
- Note the drive's commutation or offset parameter and save a parameter backup. Parameter names differ by brand, so use that drive's manual.
- Photograph every connector, phase lead (U, V, W, PE) and cable route.
- For multi-turn absolute encoders, note the battery and the machine reference; the origin may need setting again.
- Check the holding brake: it should release at rated voltage (often 24 V DC) and hold when de-energised. Support vertical axes mechanically first.
- Scribe a witness mark across the feedback housing and the motor body.
- Do not loosen the encoder hub or resolver stator unless the job needs it. If it must come off, plan a full alignment; a witness mark does not replace one.
- Replace the bearing like for like (size, seals, clearance class, insulated or hybrid type). Use a press or puller; never hammer the shaft.
- Plan the alignment and test run into the same job.
Make it planned maintenance, not a breakdown job
A worn servo bearing usually gives warning, a slight noise while the motor still runs, yet many plants wait for the breakdown. Instead, schedule the change in your own window: a Sunday, a night shift, or on site for critical machines, with encoder alignment or resolver tuning in the same job, so the motor goes back proven. If you are not sure whether the noise is the bearing or an electrical fault, read servo bearing failure vs electrical fault.
If it has already gone wrong: what to do next
- Stop power-cycling and forcing runs. Each attempt heats the winding, stresses the drive and can move the axis violently.
- Read the drive's alarm history and write down the exact codes and text.
- Check the basics: connector seating, phase order against your photos, cable damage and brake release. Our encoder alarm guide explains how to split the cable from the encoder.
- Redo the commutation alignment by the drive maker's procedure, or on a bench with the motor uncoupled. Use an automatic phase search only where the maker permits it and the axis can move safely. The bench method is described in how to check servo encoder alignment yourself. For resolvers, see resolver repair and alignment.
- Verify: run at no load in both directions, compare the current with the nameplate, then run under load. See what a no-load and load test records.
Symptom after bearing change: likely cause and fix
| Symptom after bearing change | Likely cause | Fix |
|---|---|---|
| Motor does not turn, or twitches and stops | Commutation offset lost; encoder or resolver moved against the rotor | Re-align the feedback to the rotor by the drive maker's procedure or on a bench |
| Overcurrent trip soon after enable | Wrong offset, or phase leads swapped | Check the phase order against your photos, then verify the offset |
| Runs away or runs in the wrong direction | Offset off by a large angle, swapped phases, or reversed feedback direction | Stop at once; check the wiring and feedback direction, then re-align |
| Runs rough, noisy or hot at light load | Partial misalignment, or bearing preload and fit problems | Verify the alignment; check the bearing fit, preload washer and shaft run-out |
| Encoder or resolver alarm | Connector not seated, damaged cable, contaminated disc, or lost encoder data | Reseat and inspect the connectors and cable; test the feedback device; reprogram stored data where the model requires it |
| Position lost after power-up | Multi-turn battery removed or machine origin not set | Restore the battery and set the reference by the machine procedure |
| Axis drops or brake drags | Brake not released or air gap disturbed | Check the brake voltage and release, then inspect the brake |
When to send the motor to a bench
Send it when the feedback device was removed, the maker's alignment reference is missing, a serial encoder may have lost data, or faults persist. Include your photos, parameter notes and the exact alarm text. Star Automations aligns encoders and resolvers to the rotor and proves every motor with a run test before dispatch, from Puducherry, Chennai, Bengaluru, Hyderabad and Delhi; see encoder alignment and programming and servo motor repair.
Plan your next bearing change with alignment included. Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment, or use the contact page.
FAQ
Why won't my servo motor run after changing the bearing?
The encoder or resolver was most likely disturbed against the rotor, so the commutation offset no longer matches the magnets. The motor jerks, trips or does not turn until the feedback is re-aligned; some serial encoders also need stored data checked.
Can I change a servo motor bearing without removing the encoder?
On some designs the front bearing can be changed without disturbing the rear feedback device. If the encoder or resolver must come off, plan an alignment check, because a witness mark alone does not guarantee the offset.
What is a commutation offset in a servo motor?
It is the angle between the feedback device's zero position and the rotor's magnetic pole. The drive uses it to energise the U, V and W windings at the right time. If it is wrong, torque drops, current rises, or the motor can run away.
How do I align a resolver after a bearing change?
The resolver stator is rotated to its electrical zero against the locked rotor and then clamped, following the drive or motor maker's procedure. Some drives also store a resolver offset parameter. The result is verified with a no-load run in both directions and a current check.
Is it safe to keep power-cycling a servo motor that trips after repair?
No. Repeated attempts can overheat the winding, stress the drive and cause sudden axis movement. Stop, read the alarm history, check wiring and brake, and re-align first.
Should a servo bearing change be planned maintenance?
Yes. A noisy bearing usually gives warning. Schedule the change in a Sunday, night-shift or on-site window, with encoder alignment or resolver tuning in the same job, to avoid an unplanned breakdown.