VFD repair · ABB · India
ABB drive repair in India: ACS580, ACS880, ACS800, ACS550
ABB drives usually fail from overcurrent, DC link problems, overheating, failed fans or a damaged power stage. Star Automations repairs ABB variable frequency drives, finds the fault on the bench and tests the drive before return. Star Automations is an independent repairer and is not an ABB authorised service provider.
ABB drive families we repair
- ACS150, ACS310, ACS355 and ACS550 general-purpose drives
- ACS580 general-purpose and ACS880 industrial drives
- ACS800 industrial drives
- ACS560 drives: see ABB ACS560 repair
Other ABB products: ABB servo motor repair, ABB VFD repair, Bengaluru.
Common ABB ACS580 and ACS880 fault codes
| Code | Fault | Usual area to check |
|---|---|---|
| 2310 | Overcurrent | Motor, motor cable, output stage |
| 2340 | Short circuit | Motor cable, motor winding, IGBT output stage |
| 2381 | IGBT overload | Load, switching frequency, power stage cooling |
| 3130 | Input phase loss | Supply, input fuses, rectifier |
| 3181 | Wiring or earth fault | Motor and cable insulation, wiring |
| 3210 | DC link overvoltage | Braking, deceleration time, supply voltage |
| 3220 | DC link undervoltage | Supply, DC link capacitors, charging circuit |
| 3381 | Output phase loss | Motor cable, motor, output stage |
| 4110 | Control board temperature | Cabinet cooling, fans, control board |
| 4210 | IGBT overtemperature | Fans, heat sink, load, power stage |
| 4310 | Excess temperature | Cooling, ambient temperature, load |
Codes are from ABB ACS580 and ACS880 firmware fault lists. Other families may number faults differently. Check the manual for your drive.
How the repair works
Intake
Send the drive with the nameplate photo and fault code. We check repairability before you courier.
Diagnosis
We test the power stage, DC link, fans, charging circuit and control board on the bench.
Repair and test
We repair or replace the failed parts and test the drive before it goes back.
ABB drives and spares
See ABB in stock, ABB spares, ACS580-01-25A-4 and ACS880-01-25A-3. For a drive that is no longer repairable see obsolete drive retrofit.
ABB drive repair questions
Do you repair ABB drives?
Yes. Star Automations repairs ABB variable frequency drives including ACS150, ACS310, ACS355, ACS550, ACS580, ACS800 and ACS880 families. Send the nameplate and the fault. Star Automations is an independent repairer and is not an ABB authorised service provider.
Which faults do you see most on ABB drives?
Overcurrent and short circuit trips, DC link overvoltage or undervoltage, overtemperature, failed cooling fans and failed power stages are the common ones. The fault code on the display or panel helps us place the cause.
My ABB drive shows 2310 or 2340. Is the drive dead?
Not always. These codes can come from the motor, the motor cable or the drive output stage. Check the motor and cable insulation before the drive is replaced.
What do I send for an ABB drive repair?
Send the drive with the nameplate photo, the fault code and a short note on when it trips. Include the control panel or option cards if they were fitted.
Do you have ABB drives in stock?
We hold some ABB drives and spares. See the ABB stock and spares pages, or send the part number.
Do the fault codes apply to every ABB drive?
The codes in this page are from ABB ACS580 and ACS880 firmware lists. Older families such as ACS550 and ACS355 use different numbering. Check the manual for your drive.
Send the nameplate and the fault code.
WhatsApp a nameplate photo and the fault to +91 97866 22233, or email info@starautomations.com.