Servo motor repair · INVT
INVT servo motor repair in India
Star Automations repairs INVT servo motors in India at its Puducherry factory. The lab repairs windings and bearings, aligns encoder or resolver feedback, and bench-tests the unit on a Mitchell TI-5000JX universal servo test system. Send the nameplate and we confirm repairability first. Star is independent, not an OEM service partner.
- 25+years of servo repair, since 2000
- 3,000+customers across India
- 100+servo brands covered by our universal servo motor test equipment
- 5sites: Puducherry, Chennai, Bengaluru, Hyderabad, Delhi
Every repaired unit returns with a printed test report.
How a repair starts
Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment.
Every repaired unit is tested on our bench and returns with a printed test report. Timing depends on the fault and the parts, and is stated on the quote.
- Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment
- Printed test report with every motor
- Every repair carries a warranty; terms are on the quote.
- Pickup can be arranged; parts that must be imported are quoted with their own timeline
Models and series we repair
| Series or model | What it is | Notes |
|---|---|---|
| DA200 and DA200A series | AC servo drive and motor systems | Motor and drive sold as a matched set |
| DA180 and DA180A series | AC servo drives and motors | Common on machine tools and packaging lines |
| INVT servo motors | Servo motors paired with the drives above | Send the nameplate for the exact flange size and model |
INVT alarm and error codes
Alarm codes documented in the INVT SV-DA200 manual. Check the manual for your drive and send us the code shown with the nameplate.
| Code | Meaning | What it usually points to |
|---|---|---|
| Er02-a | Encoder over-temperature | Motor or encoder running hot: bearings, winding, encoder |
| Er02-8 / Er02-9 | Encoder low-voltage and under-voltage alarms | Encoder supply, cable length and connector |
| Er05-2 | Motor and drive model mismatch | Wrong motor code set in the drive, or the wrong motor fitted |
| Er05-5 | Position control overflow (position deviation) | Encoder feedback, load or tuning |
| Er17-0 | Drive overload | Mechanical load, bearings, winding |
| Er13-0 | Main circuit overvoltage | Supply and regeneration |
Common INVT motor failures
- Encoder or feedback fault: signal loss, noise or wrong position count
- Winding overheating and insulation breakdown
- Bearing noise, shaft play and seal leaks
- Holding brake faults, where fitted
- Cable and connector damage
What the bench test checks
- Insulation and winding resistance, phase to phase and to earth
- Bearings, shaft and seals
- Holding brake, where fitted
- Encoder or resolver signal and alignment on the Mitchell TI-5000JX
- No-load run and bench run; speed and current against the nameplate
How to send the unit
- Send the nameplate: a clear photo of the nameplate and the alarm code, if any, by WhatsApp or email
- We confirm repairability: before you courier the unit
- Courier or pickup: to Puducherry, Chennai or Bengaluru
- Inspection and quote: terms are on the quote
- Repair, test, dispatch: the repaired unit is bench-tested before it leaves
From nameplate photo to a tested motor in 7 steps
One route for servo motors, encoders and drives. You see the price before any work starts, and the report before the unit leaves our bench.
- 1 · Nameplate photoSend it on WhatsApp or the form
- 2 · Repairable? QuoteWe assess the nameplate photo and confirm whether the unit is repairable.
- 3 · Courier or pickupThe unit reaches our bench
- 4 · Bench diagnosisInsulation, windings, brake, encoder
- 5 · RepairFailed parts, bearings, seals, brake
- 6 · Align and run-testEncoder aligned; no-load and load run
- 7 · Report and dispatchPrinted test report with the unit
- Line down?Servo Swap ships a tested unit first. How Servo Swap works
Timing depends on the fault and the parts, and is stated on the quote.
INVT repair FAQ
Do you repair INVT servo motors?
Yes. Star Automations repairs INVT servo motors, including motors from the DA200 and DA180 systems. Send the nameplate and we confirm repairability before you courier the unit.
Which INVT models and series do you repair?
Servo motors used with INVT DA200, DA200A, DA180 and DA180A drives. Send the nameplate for the exact model.
What does an encoder, overheating or mismatch alarm on a INVT unit mean?
On DA200 drives, Er02-a is an encoder over-temperature alarm, Er02-8 and Er02-9 are encoder voltage alarms, and Er05-2 is a motor and drive model mismatch. Send the code with the nameplate and we check the motor and encoder.
Do you need the original drive to test the motor?
No. The motor is run on the universal servo test system without the original drive, and the encoder or resolver is aligned there.
What should I send for a quote?
A photo of the nameplate, the alarm code and a note on the symptom. We confirm repairability before you courier the unit.
Can you align the encoder or resolver after repair?
Yes. Feedback is aligned on the test system after bearing, winding or feedback work, so the motor returns matched to the rotor angle.
Is there a warranty?
Every repair carries a warranty; terms are on the quote.
Are you a INVT service centre?
No. Star Automations is an independent multi-brand repair company and is not an OEM service partner.
Brand names are trademarks of their owners; Star Automations is an independent multi-brand company and is not an OEM service centre.
Send the nameplate. We confirm repairability before you courier.
WhatsApp a nameplate photo and the alarm code to +91 97866 22233, or email admin@starautomations.com.