Since 2000 · 3,000+ customers

Home / Servo motor repair / Leadshine

Servo motor repair · Leadshine

Leadshine servo motor repair in India

Star Automations repairs Leadshine servo motors, closed-loop stepper motors and feedback in India at its Puducherry factory. The lab repairs windings and bearings, aligns encoder or resolver feedback, and bench-tests the unit on a Mitchell TI-5000JX universal servo test system. Send the nameplate and we confirm repairability first. Star is independent, not an OEM service partner.

  • 25+years of servo repair, since 2000
  • 3,000+customers across India
  • 100+servo brands covered by our universal servo motor test equipment
  • 5sites: Puducherry, Chennai, Bengaluru, Hyderabad, Delhi

Every repaired unit returns with a printed test report.

How a repair starts

Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment.

Every repaired unit is tested on our bench and returns with a printed test report. Timing depends on the fault and the parts, and is stated on the quote.

  • Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment
  • Printed test report with every motor
  • Every repair carries a warranty; terms are on the quote.
  • Pickup can be arranged; parts that must be imported are quoted with their own timeline
01Models

Models and series we repair

Series or modelWhat it isNotes
ACM seriesAC servo motorsRun with ACS and ELD2 or EL7 drives
ACS seriesAC servo drivesMotor and encoder checked with the drive data
ELD2 and EL7 seriesEtherCAT servo drivesCommon on small CNC and automation machines
CS3E seriesClosed-loop stepper drives with encoderEncoder wiring and following-error alarms are common
HBS seriesHybrid servo (closed-loop stepper) motors and drivesEncoder fitted on the motor rear
ES seriesEasy servo motors and drivesSend the nameplate for the exact model
02Alarms

Leadshine alarm and error codes

Alarm codes documented for Leadshine CS3E closed-loop stepper drives. Other Leadshine series use their own tables, so check the manual for your drive and send us the code shown.

CodeMeaningWhat it usually points to
0x7321Encoder wiring error: drive may not be connected to a motor, or the encoder cable is brokenEncoder cable, connector or encoder signal on the motor
0x8611Position following errorEncoder wiring first, then low torque or excessive speed
0x0E0 / 0x2211Over-currentWiring or motor winding short
0x0C0 / 0x3211Over-voltageSupply voltage, short deceleration time
0x1A0 / 0x8402Over-speedCommanded speed too high
03Failures

Common Leadshine motor failures

  • Encoder or feedback fault: signal loss, noise or wrong position count
  • Winding overheating and insulation breakdown
  • Bearing noise, shaft play and seal leaks
  • Holding brake faults, where fitted
  • Cable and connector damage
04Bench test

What the bench test checks

  • Insulation and winding resistance, phase to phase and to earth
  • Bearings, shaft and seals
  • Holding brake, where fitted
  • Encoder or resolver signal and alignment on the Mitchell TI-5000JX
  • No-load run and bench run; speed and current against the nameplate
05Send it

How to send the unit

  • Send the nameplate: a clear photo of the nameplate and the alarm code, if any, by WhatsApp or email
  • We confirm repairability: before you courier the unit
  • Courier or pickup: to Puducherry, Chennai or Bengaluru
  • Inspection and quote: terms are on the quote
  • Repair, test, dispatch: the repaired unit is bench-tested before it leaves
→How it works

From nameplate photo to a tested motor in 7 steps

One route for servo motors, encoders and drives. You see the price before any work starts, and the report before the unit leaves our bench.

  1. 1 · Nameplate photoSend it on WhatsApp or the form
  2. 2 · Repairable? QuoteWe assess the nameplate photo and confirm whether the unit is repairable.
  3. 3 · Courier or pickupThe unit reaches our bench
  4. 4 · Bench diagnosisInsulation, windings, brake, encoder
  5. 5 · RepairFailed parts, bearings, seals, brake
  6. 6 · Align and run-testEncoder aligned; no-load and load run
  7. 7 · Report and dispatchPrinted test report with the unit
  8. Line down?Servo Swap ships a tested unit first. How Servo Swap works

Timing depends on the fault and the parts, and is stated on the quote.

07FAQ

Leadshine repair FAQ

Do you repair Leadshine servo motors, closed-loop stepper motors and feedback?

Yes. Star Automations repairs Leadshine ACM servo motors, HBS and ES motors and closed-loop stepper motors, including encoder faults. Send the nameplate and we confirm repairability before you courier the unit.

Which Leadshine models and series do you repair?

ACM servo motors, ELD2 and EL7 EtherCAT series motors, HBS hybrid servo motors, ES easy servo motors and CS3E closed-loop stepper motors. Send the nameplate for the exact model.

What does an encoder, overheating or mismatch alarm on a Leadshine unit mean?

On CS3E drives, code 0x7321 is an encoder wiring error, 0x8611 is a position following error and 0x0E0 is over-current. A motor that runs hot usually has winding or bearing damage, which the bench test checks. Send the alarm code with the nameplate.

Do you need the original drive to test the motor?

No. The motor is run on the universal servo test system without the original drive, and the encoder or resolver is aligned there.

What should I send for a quote?

A photo of the nameplate, the alarm code and a note on the symptom. We confirm repairability before you courier the unit.

Can you align the encoder or resolver after repair?

Yes. Feedback is aligned on the test system after bearing, winding or feedback work, so the motor returns matched to the rotor angle.

Is there a warranty?

Every repair carries a warranty; terms are on the quote.

Are you a Leadshine service centre?

No. Star Automations is an independent multi-brand repair company and is not an OEM service partner.

Brand names are trademarks of their owners; Star Automations is an independent multi-brand company and is not an OEM service centre.

Send the nameplate. We confirm repairability before you courier.

WhatsApp a nameplate photo and the alarm code to +91 97866 22233, or email admin@starautomations.com.