Since 2000 · 3,000+ customers

Siemens · Drives

6SL3120-1TE21-8AA3 — Siemens SINAMICS S120 single motor module: fault codes, repair & supply

The 6SL3120-1TE21-8AA3 is a SINAMICS S120 booksize single motor module that drives one axis over DRIVE-CLiQ. Star Automations sources and supplies the 6SL3120-1TE21-8AA3 and repairs failed units at component level, so you can choose between a replacement and getting your existing unit restored. This is a current OEM line. Availability and price are confirmed per enquiry. Most quotes come back the same day — send the part number or the fault code on WhatsApp.

Siemens automation spares and drives at Star Automations
01Fault codes

Common SINAMICS S120 motor module fault codes and what we usually find

Fault code wording can differ by firmware and manual revision — always confirm against the manual for your exact unit. The causes below are typical findings, not a diagnosis of your specific unit.

CodeMeaningTypical cause
F30001OvercurrentFailed power stage, motor cable short, parameter mismatch
F30002DC link overvoltageRegeneration issue, supply fault, aged capacitors
F30003DC link undervoltageLine module or DC link supply problem
F30004Heatsink overtemperatureBlocked airflow or failed fan
F30015Motor cable phase failureOpen motor phase or loose terminal
F30021Ground faultMotor or cable insulation breakdown
02Symptoms

When a 6SL3120-1TE21-8AA3 needs attention

  • Axis will not enable or trips on first move
  • Fault F30001 with a good motor and cable
  • DC link voltage unstable
  • Overheating alarms
  • No DRIVE-CLiQ link or module not recognised
03Your options

Replace or repair your 6SL3120-1TE21-8AA3

Source a replacement

Send the part number. We check sourcing from global surplus and the OEM channel and reply the same day with availability, condition and price. Advance or verified escrow applies.

Repair your existing unit

If sourcing takes longer or you want to keep your configuration, we repair at component level — power stage, gate-drive, control and supply sections — and test before dispatch.

04Related searches

What people look up for the 6SL3120-1TE21-8AA3

  • S120 motor module F30001
  • SINAMICS S120 motor module repair
  • 6SL3120-1TE21-8AA3 repair
  • S120 DC link fault
  • Siemens S120 repair India
06FAQ

6SL3120-1TE21-8AA3 — common questions

Can you supply the 6SL3120-1TE21-8AA3 in India?
Yes. Star Automations sources the 6SL3120-1TE21-8AA3 from global surplus and the OEM channel, and ships across India. Send the part number on WhatsApp +91 97866 22233 for same-day availability, condition and price.
Can a faulty 6SL3120-1TE21-8AA3 be repaired instead of replaced?
In many cases yes. We repair Siemens units at component level and test before dispatch. Send the fault code or symptom and we will tell you whether repair is practical for your unit.
My 6SL3120-1TE21-8AA3 shows F30001 (overcurrent). What should I do?
Check supply, wiring and cooling first, then send us the full fault message. Typical causes: failed power stage, motor cable short, parameter mismatch. We can quote a repair or a replacement.
Is the exact part number important?
Yes. Revision and option suffixes matter for Siemens parts. Send the full number from the nameplate, or a photo of it, and we will confirm a compatible match before you pay.

Need the 6SL3120-1TE21-8AA3 now?

Send the part number or fault code — we reply the same day. Serving Chennai, Puducherry, Bengaluru, Hyderabad, Delhi and pan-India.