Yokogawa · Spares, repair and supply
Yokogawa spares, repair and supply in India
Star Automations sources, supplies and repairs Yokogawa process instruments in India: EJA and EJX pressure transmitters, YTA temperature transmitters, ADMAG and vortex flow meters, CENTUM and STARDOM system modules, UT controllers and DX recorders. Send the full model code from the nameplate and we confirm availability or repairability.
Star Automations is an independent multi-brand repair and supply company and is not an OEM service centre.
Card failed? We repair it at board level
Before you buy a spare, check whether the failed CENTUM card can be repaired. We repair Yokogawa CENTUM VP and CS 3000 processor, I/O and power supply modules at board level. DCS card and module repair · CENTUM VP modules
We are an independent repairer, not OEM-authorised.
Yokogawa in your plant, and how an enquiry works
- Pressure and DPEJA / EJX transmitters
- TemperatureYTA transmitters
- FlowADMAG, YEWFLO, ROTAMASS
- DCS and controlCENTUM VP, CS 3000, STARDOM
- Controllers, recordersUT controllers, DX recorders
- Valves and positionersSolenoid, control valve, YVP110
- STEP 1Send the model codeA nameplate or label photo on WhatsApp is enough.
- STEP 2We checkAvailability and repairability, before you ship anything.
- STEP 3Supply, repair or alternativeThe route that is practical for your part.
- STEP 4Test and returnEach repaired unit is bench-tested first.
Yokogawa instruments and systems we handle
Pressure and DP transmitters
EJA110E, EJA430E, EJA510E, EJA530E, EJX110A, EJX430A, EJX530A and EJA118 diaphragm-seal types. Amplifier boards, indicators, capsule assemblies, covers and terminal parts. See the EJA110E page.
Temperature transmitters
YTA110, YTA310, YTA320, YTA610 and YTA710 head-mount and field-mount transmitters.
Flow meters
ADMAG AXF magnetic flow meters (converters and flow tubes), YEWFLO DY vortex and ROTAMASS Coriolis meters.
DCS and control systems
CENTUM VP, CENTUM CS 3000 and CS 1000, CENTUM XL, STARDOM and ProSafe-RS. Controller cards, I/O modules, power supplies, bus couplers and repeaters, operator station parts. We repair CENTUM I/O, processor and power supply modules at board level. See CENTUM VP spares and module repair.
Controllers and recorders
UT35A, UT55A, UT75A and UT750 controllers, UP series, and DX, FX, GX, GP and µR recorders.
Analyzers and positioners
FLXA21 and FLXA202 pH, ORP and conductivity analyzers, dissolved oxygen analyzers and YVP110 valve positioners.
Signal conditioners
JUXTA series isolators, converters and relay input/output cards.
Test instruments
Handheld multimeters, power meters and data acquisition units.
Model names are examples. If your Yokogawa model is not listed, send the nameplate photo; we source or repair most models, including discontinued ones where parts allow.
Parts that fail or wear most often, by family
This list follows typical failure patterns in process plants. Your fault may differ, so send the symptom with the model code.
| Family | Part or module | Why it is usually needed |
|---|---|---|
| EJA and EJX transmitters | Amplifier (CPU) assembly | Output stuck or erratic, no HART or BRAIN communication, blank display |
| EJA and EJX transmitters | Capsule (sensor) assembly | Reading drift or no response after overpressure, corrosion or process-side damage |
| EJA and EJX transmitters | Integral indicator, cover, O-ring, terminal block | Moisture ingress, cracked display, damaged cover threads |
| YTA temperature transmitters | Transmitter board or complete unit | Output fault or burnout alarm that stays after the sensor is checked |
| ADMAG AXF flow meters | Converter (transmitter head) | No output, display fault, coil drive or signal alarm |
| CENTUM and CS 3000 | Power supply modules | Module fault LED, repeated resets, intermittent loss of I/O |
| CENTUM and CS 3000 | Analog and digital I/O modules | Channel failure after surges on field wiring, no input value at the operator station |
| CENTUM and CS 3000 | Controller cards, bus couplers, repeaters | Redundancy faults, bus communication errors |
| UT controllers and DX recorders | Output relay, input card, display board | Control output stuck, wrong process value, blank display, dead recorder channel |
| FLXA analyzers | Converter board and sensors | Unstable readings, sensor ageing, display or communication faults |
Send the full model code, not just the name
Two Yokogawa transmitters with the same base model can differ in range, wetted-part material, output or approval, so a part that fits one may not fit the other. The nameplate carries what we need.
- Full MODEL line with suffix codes and any option codes after the slash
- STYLE code and serial number
- Measuring range and output type (4-20 mA with HART or BRAIN, fieldbus)
- For DCS modules, the full module code on the label, for example ADV551-P00
- A photo of the nameplate or label, and the symptom in one line
Supply, repair or alternative: how we decide
Supply
New surplus, refurbished-and-tested or used stock, as the part allows. The condition is stated in the quote.
Repair
Board-level repair where circuits and parts allow, including transmitter amplifier boards and DCS I/O, processor and power supply modules. We confirm repairability from your photo before you ship, and test the unit before return.
Alternative
For discontinued items we source from surplus stock first, then offer repair, spares consignment or a migration route. See the migration audit and repair or replace advice.
Planning ahead for an older DCS? Ask for a critical-spares list: spares consignment keeps tested modules ready for your plant.
Yokogawa part numbers on our list
A sample of the Yokogawa numbers we source, not the limit. Tap any part number to ask on WhatsApp. Discontinued lines are sourced from verified global surplus.
| Part number / series | Category | Status |
|---|---|---|
| AXF / ADMAG flowmeter ADMAG AXW150G | Process equipment parts | Current |
| AXF / ADMAG flowmeter AXF025G | Process equipment parts | Current |
| CENTUM VP DCS cards ADV551-P00 | Process equipment parts | Discontinued |
| CENTUM VP DCS cards AIP831-101 | Process equipment parts | Discontinued |
| EJA-E pressure transmitter EJA110E-JMS4G | Process equipment parts | Current |
| EJA-E pressure transmitter EJA430E-JAS4G | Process equipment parts | Current |
| EJA110E-JMS4J-912EB | Process equipment parts | Enquire |
Valves, solenoid valves and positioners for the same loop
A transmitter fault often sits next to a valve problem. Star Automations also supplies and repairs the valve side of the loop:
Where these instruments run
Instrument and maintenance teams in refineries and petrochemicals, chemicals and fertiliser, pharma and food, power and captive plants, water and wastewater, steel, cement and paper plants use Yokogawa transmitters, flow meters and control systems. Spares and repair needs come up most during shutdowns and after surges or moisture ingress.
Send the model code
Name, contact and the nameplate photo are enough to start.
Message received
Our team replies by email or WhatsApp with the next step. For anything urgent, WhatsApp +91 97866 22233.
Yokogawa spares and repair: common questions
Do you supply Yokogawa spares in India?
Yes. We source Yokogawa transmitters, DCS and I/O modules, flow meter converters, controllers and recorder parts as new surplus, refurbished-and-tested or used stock, and the condition is stated in the quote. Send the full model code from the nameplate and we confirm availability.
Are you a Yokogawa authorised dealer or service centre?
No. Star Automations is an independent multi-brand repair and supply company and is not an OEM service centre. For a new instrument under OEM warranty, contact Yokogawa or its channel partners. We help when you need a spare, a repair or an obsolete part.
Which Yokogawa parts fail or wear most often?
In process plants the usual ones are transmitter amplifier boards and integral indicators, DCS power supply and I/O modules, controller output relays and recorder input cards. Moisture, vibration, surges on field wiring and age decide which one fails in your plant.
Can you repair a Yokogawa EJA or EJX transmitter?
We repair amplifier (CPU) boards and indicators where circuits and parts allow. Sensor capsule faults, for example after overpressure or corrosion, often need a replacement capsule or transmitter, and we tell you which route is practical. Send the nameplate photo and the fault first. See the EJA110E page for parts and checks.
What should I send for a quote?
The full model line with suffix and option codes, the style code and serial number from the nameplate, the measuring range and output type, and the fault or symptom. For DCS modules, send the full module code printed on the label and a photo of the module.
Do you handle discontinued CENTUM and older DCS parts?
Yes. We source CENTUM modules from surplus stock and repair CENTUM I/O, processor and power supply modules at board level where circuits and parts allow, testing each module before return. For older systems it also helps to list your critical spares now and plan a migration route; ask about our migration audit. See CENTUM VP spares and module repair.
Can I buy only the amplifier or the capsule, not the whole transmitter?
Yes. The part must match the model, suffix codes and serial range, so send the full nameplate details. On flameproof transmitters the replacement part must carry the same part number, and the measuring range cannot be changed on site.
What condition and warranty do the parts come with?
Condition is stated for every item: new surplus, refurbished and tested, or used. Warranty terms are stated on each quotation.
Do you also supply solenoid valves, control valves and positioners?
Yes. See our page on solenoid valves, control valves and positioners. We also repair valve actuator electronics and smart positioners, which helps when the same loop has a Yokogawa transmitter and a valve that needs attention.
Is a repaired transmitter safe for a safety-instrumented loop?
Repaired electronics are tested before return. For safety-instrumented functions, keep your own proof-test and validation procedures in place after any repair or replacement.
Related: Automation spares catalogue · Obsolete spares · Parts request · Surplus buy-back