Since 2000 · 3,000+ customers

Servo motor repair · Kollmorgen

Kollmorgen servo motor repair

Star Automations repairs Kollmorgen servo motors, including AKM, Goldline and Seidel 6SM, at its Puducherry factory. The lab checks insulation, rewinds stators, replaces bearings and seals, and aligns the resolver or Hiperface and EnDat feedback on a universal servo test system. Timing depends on the fault and the parts, and is stated on the quote. Star is independent, not an OEM service partner.

Kollmorgen AKM22E-ANB2R-00 servo motor
  • 26years of servo repair, since 2000
  • 3,000+customers across India
  • 100+servo brands covered by our universal servo motor test equipment
  • 5sites: Puducherry, Chennai, Bengaluru, Hyderabad, Delhi

Every repaired unit returns with a printed test report.

How a repair starts

Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment.

Every repaired unit is tested on our bench and returns with a printed test report. Timing depends on the fault and the parts, and is stated on the quote.

  • Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment
  • Printed test report with every motor
  • Every repair carries a warranty; terms are on the quote.
  • Pickup can be arranged; parts that must be imported are quoted with their own timeline
01Series

Servo motor series we repair

Kollmorgen AKM

Servo motor repair and bench test.

Kollmorgen AKM2G

Servo motor repair and bench test.

02Failures

Common Kollmorgen servo motor failures

Encoder and feedback faults

Feedback faults, whether resolver or encoder, and cable damage.

Bearing noise

High-cycle axes wear bearings early; noise and heat show first.

Brake faults

Brakes that drag on release or slip when holding a load.

Cable and connector damage

Flexing in cable chains breaks feedback and power leads at the motor connector.

03Test bench

What the test bench checks

  • Insulation resistance and hi-pot
  • Winding resistance and balance
  • Encoder or resolver feedback and commutation offset
  • Brake release and holding, where fitted
  • No-load run and bench run; speed and current against the nameplate
  • Vibration and noise at rated speed
Kollmorgen AKM22E-ANB2R-00 servo motor nameplate
AKM22E-ANB2R-00 nameplate
04Next

Before you send it

05How to send

How to send the motor

You can send a servo motor from anywhere in India. Talk to us before you courier, so the unit is expected and logged on arrival.

  1. Send the nameplate

    WhatsApp a clear photo of the nameplate, the alarm code and what the machine was doing when it failed.

  2. We confirm repairability

    We tell you whether we can test and repair that model before anything is shipped.

  3. Courier or pickup

    Courier the motor to our bench, or ask us to arrange pickup where needed.

  4. Inspection and quote

    The motor is opened, inspected and photographed. You get the findings and a quote before work starts.

  5. Repair, test, dispatch

    Repaired, run-tested and bench-tested, then dispatched with a printed test report.

Kollmorgen servo motor series and models we repair

We repair all frame sizes and ratings in these series, including older and discontinued versions. The list is a guide, not a limit: send us the nameplate. See also AC servo motor repair and all servo motor brands.

AKM and AKM2G

All frame sizes, with resolver, SFD and encoder feedback

Older

Goldline series and Pacific Scientific servo motors

Kollmorgen models and feedback

SeriesFeedbackTypical faults
AKMResolver, SFD, Hiperface, EnDatFeedback fault, overheating, brake not releasing
Goldline B, EB, XTResolverWinding short, resolver fault
Seidel 6SMResolver, HiperfaceBearing wear, feedback fault

What the lab does on every Kollmorgen motor

Check or repairWhat it covers
Insulation and stator surge/hipot testingFinds winding weakness before it becomes a short
Vacuum-pressure rewindingStators are rewound when the winding is damaged
Bearing and IP65 oil-seal restorationBearings replaced and seals restored
Rotor balancingRotor is balanced after repair
Holding-brake torque testBrake release and holding torque are tested
Resolver or encoder alignmentFeedback is aligned on India's first universal servo motor test system
Signature analysis (QMax QT-205)Used on feedback and interface boards

Repair routes

RouteWhat it means
RepairYour own motor is repaired and returned.
Tested replacementA tested motor is supplied where one is available.
ExchangeYour faulty motor is swapped against a tested one, subject to availability.

Every repair carries a warranty; terms are on the quote. Star is independent, not an OEM service partner.

→How it works

From nameplate photo to a tested motor in 7 steps

One route for servo motors, encoders and drives. You see the price before any work starts, and the report before the unit leaves our bench.

  1. 1 · Nameplate photoSend it on WhatsApp or the form
  2. 2 · Repairable? QuoteWe assess the nameplate photo and confirm whether the unit is repairable.
  3. 3 · Courier or pickupThe unit reaches our bench
  4. 4 · Bench diagnosisInsulation, windings, brake, encoder
  5. 5 · RepairFailed parts, bearings, seals, brake
  6. 6 · Align and run-testEncoder aligned; no-load and load run
  7. 7 · Report and dispatchPrinted test report with the unit
  8. Line down?Servo Swap ships a tested unit first. How Servo Swap works

Timing depends on the fault and the parts, and is stated on the quote.

06Questions

Kollmorgen servo motor questions

Do you repair Kollmorgen servo motors?

Yes, including AKM and AKM2G series motors. Send the nameplate and we confirm repairability before you courier.

Which Kollmorgen motor families do you repair?

AKM, AKM2G, Goldline and Seidel 6SM servo motors. Send the nameplate and we confirm repairability.

Do you need a Kollmorgen drive to test the motor?

No. The universal servo motor test system runs Kollmorgen motors without the original drive, and the motor is then bench-tested.

Can you align the resolver or encoder after repair?

Yes. Resolver, Hiperface and EnDat feedback is aligned on the test system after bearing, winding or feedback work.

What should I send for a quote on a Kollmorgen motor?

A photo of the nameplate, the alarm code and a note on the symptom. We confirm repairability before you courier.

Do you also repair Kollmorgen servo drives?

Yes. See the Kollmorgen servo drive repair page for drive models and how to send a unit.

Are you a Kollmorgen service centre?

No. Star Automations is an independent multi-brand repair company and is not an OEM service partner.

Is there a warranty?

Every repair carries a warranty; terms are on the quote.

Encoders and feedback on these motors

AKM motors use Hengstler incremental or EnDat encoders; Goldline and Seidel 6SM motors often use resolvers. See incremental encoders, EnDat and resolver repair.

Send the nameplate. We confirm repairability before you courier.

WhatsApp a nameplate photo and the alarm code to +91 97866 22233, or email admin@starautomations.com.

Can the resolver or encoder be aligned without our drive?

Yes. Star Automations aligns the feedback on its universal servo motor test system, so the motor returns matched to the rotor angle without needing your drive.

Do you test the holding brake?

Yes. The holding-brake torque is tested as part of the repair.

Is Star Automations an OEM service partner?

No. Star is independent, not an OEM service partner.

Also see: Kollmorgen servo drive repair