Excitation and AVR repair
Generator excitation panel and AVR repair and refurbishment in India
Star Automations repairs and refurbishes generator excitation panels and automatic voltage regulators, including GE EX2100 and EX2000 boards, ABB UNITROL, Basler and Leroy-Somer digital AVRs, and Mitsubishi excitation panels. We have repaired and refurbished a Mitsubishi excitation panel from an Ebara pump set. Captive power plants, hydro and thermal generators and marine alternators send us excitation boards and panels.
Send your part number for a quote
Send the part number, a photo of the nameplate and the fault on WhatsApp or the quote form. We reply with how we can help and a quote.
Excitation systems and AVRs we repair
These are examples of makes and series we handle. If yours is not listed, send it anyway.
| Part number or model | Family | What usually brings it to us | Service |
|---|---|---|---|
| GE EX2100 | Excitation or AVR equipment | Loss of excitation, voltage control fault, firing or power board failure | Repair, tested replacement or exchange |
| GE EX2000 | Excitation or AVR equipment | Loss of excitation, voltage control fault, firing or power board failure | Repair, tested replacement or exchange |
| ABB UNITROL | Excitation or AVR equipment | Loss of excitation, voltage control fault, firing or power board failure | Repair, tested replacement or exchange |
| Basler digital AVR | Excitation or AVR equipment | Loss of excitation, voltage control fault, firing or power board failure | Repair, tested replacement or exchange |
| Leroy-Somer digital AVR | Excitation or AVR equipment | Loss of excitation, voltage control fault, firing or power board failure | Repair, tested replacement or exchange |
| Mitsubishi excitation panel | Excitation or AVR equipment | Loss of excitation, voltage control fault, firing or power board failure | Repair, tested replacement or exchange |
We repair boards and panels. The plant commissions the excitation system on its own generator.
Common symptoms and what to check
| Symptom | What to check first |
|---|---|
| Generator voltage hunts or does not build | Check field supply and sensing, then send the AVR or board |
| Loss of excitation alarm | Check the excitation supply and firing, then send the board |
| Firing board fault | Send the board for signature analysis |
| Field flashing does not work | Check the flashing supply, then send the module |
| Panel does not power up | Check supply, then send the panel or board |
Send the fault description and photos on WhatsApp and we tell you what we see.
How we repair and test your board
- Receive and logPart number, nameplate and the fault are recorded.
- Visual inspectionBurnt parts, damaged tracks and connectors are checked.
- Signature analysisThe board is analysed on a QMax QT-205 to find the failed components.
- Component-level repairFailed parts are replaced and the board is cleaned.
- Bench testThe repaired board is bench tested before it leaves us.
- DispatchThe board is packed and sent back to your plant.
Repair, tested replacement or exchange
| Option | When it fits | What you send |
|---|---|---|
| Repair | You want your own board back, repaired | The faulty board |
| Tested replacement | The plant cannot wait for a repair, and a unit is available | Part number and nameplate photo |
| Exchange | You want a tested unit now and will send yours | Your board, sent in exchange |
Where we work from
We work from Puducherry, Chennai and Bengaluru, with offices in Hyderabad and Delhi. Boards come to us from across India and from abroad. See international repair and return. Related: DCS and control card repair, genset controller repair.
Frequently asked questions
Do you repair generator excitation panels and AVRs?
Yes. We repair GE EX2100 and EX2000 boards, ABB UNITROL, Basler and Leroy-Somer digital AVRs, and Mitsubishi excitation panels.
What should I send for a repair quote?
Send the part number, a photo of the nameplate and a short description of the fault on WhatsApp +91 97866 22233 or through the quote form. We reply with how we can help and a quote.
Can you repair a board the OEM no longer supports?
Yes, in most cases. We repair at the component level, so the work does not depend on OEM support. Where a part cannot be sourced we tell you before we proceed.
How do you test a board before it goes back?
We inspect it, analyse its signature on a QMax QT-205, repair the failed components and bench test it before dispatch.
Should I choose repair, a tested replacement or an exchange?
Repair keeps your own board. A tested replacement or exchange suits a plant that cannot wait. Send the part number and we tell you what is possible.
Can you repair a full excitation panel?
Yes. We have repaired and refurbished a Mitsubishi excitation panel from an Ebara pump set, and we repair excitation boards and AVRs from other makers.
Does the repair carry a warranty?
Every repair carries a warranty; terms are on the quote.
Is Star Automations an OEM service partner?
No. Star Automations is an independent repair company, not an OEM service partner.
Can you take boards from outside India?
Yes. We receive boards from across India and from abroad. See our international repair and return page for the steps.
How much does a repair cost?
The cost depends on the board and the fault. Send the part number and a photo of the nameplate, and we reply with a quote.