Since 2000 · 3,000+ customers

Mitsubishi · Drives

FR-A840-00250-2-60 — FR-A800 inverter: fault codes, repair & supply

The FR-A840-00250-2-60 is a Mitsubishi FR-A800 series 400 V-class inverter. Check the nameplate for the exact rating. Star Automations sources and supplies the FR-A840-00250-2-60 and repairs failed units at component level, so you can choose between a replacement and getting your existing unit restored. This is a current OEM line. Availability and price are confirmed per enquiry. Most quotes come back the same day — send the part number or the fault code on WhatsApp.

Mitsubishi automation spares and drives at Star Automations
01Fault codes

Common FR-A800 fault codes and what we usually find

Fault code wording can differ by firmware and manual revision — always confirm against the manual for your exact unit. The causes below are typical findings, not a diagnosis of your specific unit.

CodeMeaningTypical cause
E.OC1Overcurrent during accelerationShort circuit, too-short acceleration, motor insulation
E.OC2Overcurrent at constant speedSudden load change, motor or cable fault
E.OC3Overcurrent during decelerationShort deceleration time, load fault
E.OV1Regenerative overvoltage during accelerationSupply surge, regenerative load
E.OV2Regenerative overvoltage at constant speedRegenerative load, supply surge
E.OV3Regenerative overvoltage during decelerationShort deceleration time, no braking resistor
E.THTInverter overloadSustained overload, undersized drive
E.THMMotor overloadMechanical overload, wrong motor setting
E.FINHeat sink overheatBlocked airflow, failed cooling fan
E.ILFInput phase lossMissing supply phase, loose terminal
E.LFOutput phase lossMotor cable break, failed output stage
E.GFOutput-side earth faultMotor or cable insulation failure
E.PEParameter storage element errorFailed control board memory
E.CPUCPU errorControl board fault or noise
02Symptoms

When a FR-A840-00250-2-60 needs attention

  • Inverter trips on E.OC1, E.OV or E.THT
  • Fan alarm or overheating
  • Display blank or inverter will not start
  • Burnt smell or damaged power stage
  • Trips under load
03Your options

Replace or repair your FR-A840-00250-2-60

Source a replacement

Send the part number. We check sourcing from global surplus and the OEM channel and reply the same day with availability, condition and price. Advance or verified escrow applies.

Repair your existing unit

If sourcing takes longer or you want to keep your configuration, we repair at component level — power stage, gate-drive, control and supply sections — and test before dispatch.

04Related searches

What people look up for the FR-A840-00250-2-60

  • FR-A840-00250-2-60 repair
  • FR-A840-00250-2-60 price India
  • Mitsubishi FR-A800 E.OC1
  • Mitsubishi FR-A800 E.OV3
  • Mitsubishi FR-A800 E.THT
  • Mitsubishi FR-A800 repair
06FAQ

FR-A840-00250-2-60 — common questions

Can you supply the FR-A840-00250-2-60 in India?
Yes. Star Automations sources the FR-A840-00250-2-60 from global surplus and the OEM channel, and ships across India. Send the part number on WhatsApp +91 97866 22233 for same-day availability, condition and price.
Can a faulty FR-A840-00250-2-60 be repaired instead of replaced?
In many cases yes. We repair Mitsubishi units at component level and test before dispatch. Send the fault code or symptom and we will tell you whether repair is practical for your unit.
My FR-A840-00250-2-60 shows E.OC1 (overcurrent during acceleration). What should I do?
Check supply, wiring and cooling first, then send us the full fault message. Typical causes: short circuit, too-short acceleration, motor insulation. We can quote a repair or a replacement.
Is the exact part number important?
Yes. Revision and option suffixes matter for Mitsubishi parts. Send the full number from the nameplate, or a photo of it, and we will confirm a compatible match before you pay.

Need the FR-A840-00250-2-60 now?

Send the part number or fault code — we reply the same day. Serving Chennai, Puducherry, Bengaluru, Hyderabad, Delhi and pan-India.