Since 2000 · 3,000+ customers

Home / Encoder and feedback repair / SSI and BiSS absolute encoder

Feedback devices · Absolute

SSI and BiSS absolute encoder repair and fault diagnosis

An SSI or BiSS absolute encoder reports its exact position over a clocked serial link, so the position is known at power-up. Star Automations repairs these encoders, checks the clock and data signals, and arranges exchange, retrofit or board rebuild when a model is obsolete. Send the nameplate and the interface type.

  • 25+years of servo repair, since 2000
  • 3,000+customers across India
  • 100+servo brands covered by our universal servo motor test equipment
  • 5sites: Puducherry, Chennai, Bengaluru, Hyderabad, Delhi

Every repaired unit returns with a printed test report.

How a repair starts

Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment.

Every repaired unit is tested on our bench and returns with a printed test report. Timing depends on the fault and the parts, and is stated on the quote.

  • Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment
  • Printed test report with every motor
  • Every repair carries a warranty; terms are on the quote.
  • Pickup can be arranged; parts that must be imported are quoted with their own timeline
01Anatomy

How a absolute encoder works and where it fails

The drive or controller sends a clock, and the encoder answers with its position in data bits. A wrong clock, a bad cable or a failing encoder gives no data or a wrong position.

absolute encoder signal pathSignal path from the sensing element to the drive. Numbers mark the common failure points.Code disc and sensorPosition source1ElectronicsSerial interface2Cable and connectorClock and data3Controller inputClock and read4
  1. Code disc and sensor: The disc and sensor read the absolute code. Dirt and damage give wrong values.
  2. Electronics: The board turns the code into SSI or BiSS data. Ageing parts give data errors.
  3. Cable and connector: The clock and the data pairs need a good shield. Breaks and noise give errors.
  4. Controller input: The controller sends the clock and reads the position. A wrong clock rate or format setting gives a wrong value.
02Types

Types, makers and where they are used

TypeOutputWhere it is used
SSI single-turnSerial position over one revolutionMachine axes, presses
SSI multi-turnSerial position over many revolutionsCranes, lifts, wind turbines
BiSS-CFast serial position, bidirectionalServo drives and CNC
Parallel absolutePosition on parallel linesOlder machines
03Faults

Fault symptoms, causes and safe checks

Tap a symptom for the likely causes and the safe checks. Switch off and lock out before touching any wiring.

No data or the position reads zero

Likely causes: The clock is not arriving, the data line is open, or the supply is missing.

Safe checks: With the supply off, check the clock and data wires and the shield. Then check the supply at the encoder end.

Wrong position or jumps

Likely causes: Noise on the cable, a wrong bit format setting, or a failing code reading.

Safe checks: Check the format setting against the manual. Check the shield and the ground connection.

Position error after a power cut

Likely causes: A multi-turn encoder lost its multi-turn count.

Safe checks: Check the encoder type and its multi-turn memory. Follow the homing steps for the machine.

Alarm only on some positions

Likely causes: A dirty or damaged spot on the code disc.

Safe checks: Turn the shaft by hand with the supply off and check for dirt or damage when the cover is open. Do not open a sealed encoder.

Alarm when hot

Likely causes: Electronics drift with heat.

Safe checks: Compare the data on the bench at normal and warm temperature.

04Diagnosis

Diagnosis flow: find the fault in five steps

Diagnosis flowFive steps to find the fault, from the cable to the sensing element.1
Check supply and cable at the encoder end
2
Inspect connector and shield
3
Scope the output signals
4
Compare with a known good unit
5
Repair, align or replace

Most feedback faults sit in the cable, the connector or the supply, not in the sensing element. Check those first.

05Alternatives

Not repairable or not available? Your options

When a absolute encoder cannot be repaired or is no longer sold, there are five routes.

RouteWhat it means here
RepairRepair and test the absolute encoder on our encoder test setup, and re-align it to the motor.
ExchangeA tested unit of the same type, with the output matched to your drive.
SourcingThe exact part through our offices and partners abroad, then tested.
RetrofitA current encoder with the same output, resolution and mounting, or an adapter. The drive must support it, and the commutation angle is set again.
Board rebuildIf the encoder or its electronics are obsolete, we reverse-engineer and rebuild the board.

More on replacement options

06Brands

Absolute encoder makers we repair

MakerNotes
Sick-Stegmann, Heidenhain, Posital, Lika, Hengstler, TR ElectronicMany models are already covered on our encoder pages
OthersSend the nameplate and the interface type
→How it works

From nameplate photo to a tested motor in 7 steps

One route for servo motors, encoders and drives. You see the price before any work starts, and the report before the unit leaves our bench.

  1. 1 · Nameplate photoSend it on WhatsApp or the form
  2. 2 · Repairable? QuoteWe assess the nameplate photo and confirm whether the unit is repairable.
  3. 3 · Courier or pickupThe unit reaches our bench
  4. 4 · Bench diagnosisInsulation, windings, brake, encoder
  5. 5 · RepairFailed parts, bearings, seals, brake
  6. 6 · Align and run-testEncoder aligned; no-load and load run
  7. 7 · Report and dispatchPrinted test report with the unit
  8. Line down?Servo Swap ships a tested unit first. How Servo Swap works

Timing depends on the fault and the parts, and is stated on the quote.

07FAQ

Frequently asked questions

What is the difference between SSI and BiSS?

Both send the position serially after a clock. BiSS is faster and can send extra data both ways; SSI is simpler and older. The controller must support the type fitted.

Why does my absolute encoder lose position?

Common causes are a lost multi-turn count after a power cut, noise on the cable, or a failing encoder. Check the cable and supply first.

Can an absolute encoder be replaced with another make?

Sometimes. The interface, resolution, bit count, supply and mounting must match, and the machine zero must be set again.

Can you repair an obsolete absolute encoder?

Often yes. If parts are not available we reverse-engineer and rebuild the board, or arrange an exchange or retrofit.

See also