Since 2000 · 3,000+ customers

Home / Encoder and feedback repair / Resolver

Feedback devices · Resolver

Resolver repair and fault diagnosis

A resolver is a rugged rotary transformer that gives sine and cosine signals showing the shaft angle. It has no electronics inside, so it suits hot and dirty motors. Star Automations repairs and aligns resolvers, tests the signals on our encoder test oscilloscope, and arranges exchange or retrofit. Send the nameplate.

  • 26years of servo repair, since 2000
  • 3,000+customers across India
  • 100+servo brands covered by our universal servo motor test equipment
  • 5sites: Puducherry, Chennai, Bengaluru, Hyderabad, Delhi

Every repaired unit returns with a printed test report.

How a repair starts

Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment.

Every repaired unit is tested on our bench and returns with a printed test report. Timing depends on the fault and the parts, and is stated on the quote.

  • Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment
  • Printed test report with every motor
  • Every repair carries a warranty; terms are on the quote.
  • Pickup can be arranged; parts that must be imported are quoted with their own timeline
01Anatomy

How a resolver works and where it fails

The drive sends an excitation signal to the resolver. The resolver returns two signals whose size changes with the shaft angle, and the drive works out position and speed from them.

resolver signal pathSignal path from the sensing element to the drive. Numbers mark the common failure points.Rotor and statorAngle sensing1ExcitationDrive output2Cable and connectorSignal path3Drive converterResolver to digital4
  1. Rotor and stator: The windings make sine and cosine signals. Shorted turns, damage or a loose rotor give errors.
  2. Excitation: The drive sends an AC reference. A weak or missing reference gives no signal.
  3. Cable and connector: Several twisted pairs carry the signals. A break or poor shield gives errors.
  4. Drive converter: The drive converts the signals to position. A wrong pole pair or offset setting gives wrong values.
02Types

Types, makers and where they are used

TypeNotesWhere it is used
Single-speed resolverOne electrical cycle per turnServo motors, simple axes
Multi-speed resolverSeveral cycles per turn, finer resolutionPrecision axes
Brushless resolverNo slip rings, long lifeServo motors, aerospace, defence
Synchro and resolver for defenceSpecial rotary position devicesRadar, aircraft, ship systems
03Faults

Fault symptoms, causes and safe checks

Tap a symptom for the likely causes and the safe checks. Switch off and lock out before touching any wiring.

Resolver fault or feedback loss alarm at power-up

Likely causes: A broken signal or reference wire, or a damaged resolver winding.

Safe checks: With the supply off, measure the winding resistances against the manual and check the cable pairs for breaks.

Motor runs rough, hunts or vibrates

Likely causes: The resolver is out of alignment with the motor, or the signal levels are unequal.

Safe checks: The resolver offset must match the motor. A re-alignment on a test setup fixes this.

Speed noise at certain angles

Likely causes: A shorted turn, a damaged winding or a loose rotor.

Safe checks: Compare the sine and cosine signals on an oscilloscope with a known good resolver.

Fault only when hot or after vibration

Likely causes: A cracked wire, a loose connector or winding insulation breakdown.

Safe checks: Check the connector, the wires at the motor end and the insulation.

New resolver, motor will not run correctly

Likely causes: The offset or the pole pair setting does not match.

Safe checks: The resolver must be aligned to the motor. Do not guess the offset.

04Diagnosis

Diagnosis flow: find the fault in five steps

Diagnosis flowFive steps to find the fault, from the cable to the sensing element.1
Check supply and cable at the device end
2
Inspect connector and shield
3
Scope the output signals
4
Compare with a known good unit
5
Repair, align or replace

Most feedback faults sit in the cable, the connector or the supply, not in the sensing element. Check those first.

05Alternatives

Not repairable or not available? Your options

When a resolver cannot be repaired or is no longer sold, there are five routes.

RouteWhat it means here
RepairRepair and test the resolver on our encoder test setup, and re-align it to the motor.
ExchangeA tested unit of the same type, with the output matched to your drive.
SourcingThe exact part through our offices and partners abroad, then tested.
RetrofitA current device with the same output, resolution and mounting, or an adapter. The drive must support it, and the commutation angle is set again.
Board rebuildIf the device or its electronics are obsolete, we reverse-engineer and rebuild the board.

More on replacement options

06Defence and aerospace

Synchros and resolvers for special equipment

Synchros and resolvers are also used in radar, aircraft and ship systems. See our page on synchro and resolver repair.

→How it works

From nameplate photo to a tested motor in 7 steps

One route for servo motors, encoders and drives. You see the price before any work starts, and the report before the unit leaves our bench.

  1. 1 · Nameplate photoSend it on WhatsApp or the form
  2. 2 · Repairable? QuoteWe assess the nameplate photo and confirm whether the unit is repairable.
  3. 3 · Courier or pickupThe unit reaches our bench
  4. 4 · Bench diagnosisInsulation, windings, brake, encoder
  5. 5 · RepairFailed parts, bearings, seals, brake
  6. 6 · Align and run-testEncoder aligned; no-load and load run
  7. 7 · Report and dispatchPrinted test report with the unit
  8. Line down?Servo Swap ships a tested unit first. How Servo Swap works

Timing depends on the fault and the parts, and is stated on the quote.

07FAQ

Frequently asked questions

How do I test a resolver?

With the supply off, check the winding resistances against the manual and look for breaks in the cable. Then compare the sine and cosine output with a known good resolver on an oscilloscope.

Why does the motor shake after a resolver change?

The resolver offset must be aligned to the motor. A wrong offset gives rough running or a failure to start.

Can a resolver be replaced with an encoder?

Only if the drive supports the encoder type. A retrofit needs the drive, the interface and the mounting to match, and the motor commutation angle is set again.

Can you repair a resolver?

Often yes. We check the windings and the connections, repair or replace them, and align the resolver to the motor.

See also