Linear scale and magnetic encoder repair and fault diagnosis

A linear scale or magnetic encoder measures straight-line position on a machine axis, and a glass scale or magnetic tape is read by a scanning head. Star Automations repairs linear scales, reader heads and magnetic encoders, checks the signals, and arranges exchange or retrofit. Send the nameplate and the signal type.

  • 25+years of servo repair, since 2000
  • 3,000+customers across India
  • 100+servo brands covered by our universal servo motor test equipment
  • 5sites: Puducherry, Chennai, Bengaluru, Hyderabad, Delhi

Every repaired unit returns with a printed test report.

How a repair starts

Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment.

Every repaired unit is tested on our bench and returns with a printed test report. Timing depends on the fault and the parts, and is stated on the quote.

  • Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment
  • Printed test report with every motor
  • Every repair carries a warranty; terms are on the quote.
  • Pickup can be arranged; parts that must be imported are quoted with their own timeline
01Anatomy

How a linear scale works and where it fails

A scale with fine lines or a magnetic pattern runs along the axis. The scanning head reads it and sends pulses or sine and cosine signals. Dirt, damage or a wrong air gap gives errors.

linear scale signal pathSignal path from the sensing element to the drive. Numbers mark the common failure points.Scale or tapePosition pattern1Scanning headReads the pattern2CableSignal path3ControllerReads position4
  1. Scale or tape: A glass scale or magnetic tape. Scratches, dirt and coolant film give errors.
  2. Scanning head: The head reads the pattern. A wrong gap or a worn head gives weak signals.
  3. Cable: The cable moves with the axis, and repeated bending breaks wires.
  4. Controller: The control reads the signals. A wrong setting gives a wrong position.
02Types

Types, makers and where they are used

TypeNotesWhere it is used
Glass linear scaleHigh accuracy, sensitive to dirt and damageMachine tools, measuring machines
Magnetic tape encoderMore tolerant to dirtPresses, cutting machines
Linear motor feedbackUsed with linear motorsPrecision stages
03Faults

Fault symptoms, causes and safe checks

Tap a symptom for the likely causes and the safe checks. Switch off and lock out before touching any wiring.

Position error or axis stops with a scale alarm

Likely causes: Dirt, coolant or damage on the scale, or a weak reader signal.

Safe checks: Inspect the scale and the head for dirt, damage or coolant film, as the machine manual allows.

Signal alarm that comes and goes with axis travel

Likely causes: A cracked wire in the moving cable.

Safe checks: Flex the cable along the axis travel and check the signals, with care and the supply following the manual.

Position jumps near the ends or at one spot

Likely causes: A scratch, a joint or a damaged spot on the scale.

Safe checks: Check the scale at that position.

Alarm after a head change or after a crash

Likely causes: The air gap or the alignment is wrong.

Safe checks: Check the head gap and alignment according to the manual.

04Diagnosis

Diagnosis flow: find the fault in five steps

Diagnosis flowFive steps to find the fault, from the cable to the sensing element.1
Check supply and cable at the device end
2
Inspect connector and shield
3
Scope the output signals
4
Compare with a known good unit
5
Repair, align or replace

Most feedback faults sit in the cable, the connector or the supply, not in the sensing element. Check those first.

05Alternatives

Not repairable or not available? Your options

When a linear scale cannot be repaired or is no longer sold, there are five routes.

RouteWhat it means here
RepairRepair and test the linear scale on our encoder test setup, and re-align it to the motor.
ExchangeA tested unit of the same type, with the output matched to your drive.
SourcingThe exact part through our offices and partners abroad, then tested.
RetrofitA current device with the same output, resolution and mounting, or an adapter. The drive must support it, and the commutation angle is set again.
Board rebuildIf the device or its electronics are obsolete, we reverse-engineer and rebuild the board.

More on replacement options

→How it works

From nameplate photo to a tested motor in 7 steps

One route for servo motors, encoders and drives. You see the price before any work starts, and the report before the unit leaves our bench.

  1. 1 · Nameplate photoSend it on WhatsApp or the form
  2. 2 · Repairable? QuoteWe assess the nameplate photo and confirm whether the unit is repairable.
  3. 3 · Courier or pickupThe unit reaches our bench
  4. 4 · Bench diagnosisInsulation, windings, brake, encoder
  5. 5 · RepairFailed parts, bearings, seals, brake
  6. 6 · Align and run-testEncoder aligned; no-load and load run
  7. 7 · Report and dispatchPrinted test report with the unit
  8. Line down?Servo Swap ships a tested unit first. How Servo Swap works

Timing depends on the fault and the parts, and is stated on the quote.

06FAQ

Frequently asked questions

What are common linear scale faults?

Dirt or coolant on the scale, a damaged scale, a worn reader head and a broken moving cable are the most common.

Can a glass scale be repaired?

A damaged glass scale usually needs to be replaced, while the reader head and electronics are often repairable. We check the unit first.

Can I replace a scale with another make?

Only if the length, the signal type, the resolution and the mounting match and the control supports it.

Do you repair magnetic encoders?

Yes. We repair the heads and the electronics and check the signals.

See also

Star Automations is an independent repair company and not an OEM service partner. Brand names are used only to identify the equipment we repair. The manual for your unit is the authority for exact signals, wiring and settings.