Since 2000 · 3,000+ customers

Home / Encoder and feedback repair / Incremental encoder

Feedback devices · Incremental

Incremental encoder repair and fault diagnosis

An incremental encoder sends A and B pulses, and usually a Z index, so the drive can count position and speed. Star Automations repairs incremental encoders, checks the signals on an encoder test oscilloscope, and arranges exchange, retrofit or board rebuild when a unit is obsolete. Send the nameplate.

  • 26years of servo repair, since 2000
  • 3,000+customers across India
  • 100+servo brands covered by our universal servo motor test equipment
  • 5sites: Puducherry, Chennai, Bengaluru, Hyderabad, Delhi

Every repaired unit returns with a printed test report.

How a repair starts

Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment.

Every repaired unit is tested on our bench and returns with a printed test report. Timing depends on the fault and the parts, and is stated on the quote.

  • Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment
  • Printed test report with every motor
  • Every repair carries a warranty; terms are on the quote.
  • Pickup can be arranged; parts that must be imported are quoted with their own timeline
01Anatomy

How a incremental encoder works and where it fails

The encoder disc and sensor make pulses, the electronics shape them, the cable carries them, and the drive counts them. A fault at any of the four points looks like a wrong position or a following-error alarm.

incremental encoder signal pathSignal path from the sensing element to the drive. Numbers mark the common failure points.Disc and sensorPulse source1ElectronicsSignal shaping2Cable and connectorSignal path3Drive inputCounting4
  1. Disc and sensor: The glass or metal disc and the light or magnetic sensor make the A, B and Z pulses. Dirt, oil or a cracked disc lose pulses.
  2. Electronics: The board turns the sensor signal into clean square waves. Heat and ageing parts distort them.
  3. Cable and connector: Shield, ground and connector pins carry the pulses. Breaks and noise cause false counts.
  4. Drive input: The drive counts the pulses. A wrong supply, termination or setting gives a wrong count.
02Types

Types, makers and where they are used

TypeOutputWhere it is used
Incremental, line-driver outputA, B, Z with inverted signalsServo motors, CNC axes, spindles
Incremental, open collector or push-pullA, B, Z single-endedConveyors, drives, simple machines
Incremental with commutation tracksA, B, Z plus U, V, WBrushless servo motors
Sine-cosine incrementalAnalog sine and cosineHigh-resolution axes
03Faults

Fault symptoms, causes and safe checks

Tap a symptom for the likely causes and the safe checks. Switch off and lock out before touching any wiring.

Position drifts or the axis loses steps

Likely causes: Lost pulses from a dirty disc, a weak LED or sensor, or noise on the cable.

Safe checks: Lock out the supply, then inspect the encoder and the connector. Compare the A and B signals on an oscilloscope with a known good unit.

Following-error or deviation alarm

Likely causes: A broken wire, a bad connector pin, or a failing sensor.

Safe checks: Check continuity of the A, B and supply wires, and the shield connection, with the supply off.

Z index missing or the home position moves

Likely causes: The Z channel is lost, or the Z pulse width is wrong.

Safe checks: Check the Z signal at the encoder and at the drive. Check the home sequence settings.

Motor runs rough or vibrates

Likely causes: The commutation tracks U, V, W are wrong or out of alignment with the motor.

Safe checks: Check the U, V, W tracks against the motor phase. A re-alignment may be needed.

Alarm only when the machine is hot

Likely causes: Electronics or the sensor drift with heat.

Safe checks: Note the temperature when the alarm comes. A bench test with heat helps to confirm.

Alarm only when the motor runs fast

Likely causes: The output frequency is too high for the cable, or noise pickup rises with speed.

Safe checks: Check the cable length, shield and ground. Keep the signal cable away from the motor power cable.

04Diagnosis

Diagnosis flow: find the fault in five steps

Diagnosis flowFive steps to find the fault, from the cable to the sensing element.1
Check supply and cable at the encoder end
2
Inspect connector and shield
3
Scope the output signals
4
Compare with a known good unit
5
Repair, align or replace

Most feedback faults sit in the cable, the connector or the supply, not in the sensing element. Check those first.

05Alternatives

Not repairable or not available? Your options

When a incremental encoder cannot be repaired or is no longer sold, there are five routes.

RouteWhat it means here
RepairRepair and test the incremental encoder on our encoder test setup, and re-align it to the motor.
ExchangeA tested unit of the same type, with the output matched to your drive.
SourcingThe exact part through our offices and partners abroad, then tested.
RetrofitA current encoder with the same output, resolution and mounting, or an adapter. The drive must support it, and the commutation angle is set again.
Board rebuildIf the encoder or its electronics are obsolete, we reverse-engineer and rebuild the board.

More on replacement options

06Brands

Incremental encoder makers we repair

MakerNotes
Heidenhain, Renishaw, Lika, Sick-Stegmann, Hengstler, Dynapar, Renco, Ono SokkiMany models are already covered on our encoder pages
Yaskawa, Mitsubishi, Fanuc, Sanyo Denki, TamagawaMotor-mounted encoders, see the maker pages
OthersSend the nameplate and the signal type
→How it works

From nameplate photo to a tested motor in 7 steps

One route for servo motors, encoders and drives. You see the price before any work starts, and the report before the unit leaves our bench.

  1. 1 · Nameplate photoSend it on WhatsApp or the form
  2. 2 · Repairable? QuoteWe assess the nameplate photo and confirm whether the unit is repairable.
  3. 3 · Courier or pickupThe unit reaches our bench
  4. 4 · Bench diagnosisInsulation, windings, brake, encoder
  5. 5 · RepairFailed parts, bearings, seals, brake
  6. 6 · Align and run-testEncoder aligned; no-load and load run
  7. 7 · Report and dispatchPrinted test report with the unit
  8. Line down?Servo Swap ships a tested unit first. How Servo Swap works

Timing depends on the fault and the parts, and is stated on the quote.

07FAQ

Frequently asked questions

How do I know if my incremental encoder is faulty?

Look for lost position, following-error alarms or a missing home position. Check the supply, cable and connector first, then compare the A and B signals with a known good encoder on an oscilloscope.

Can an incremental encoder be repaired?

Often yes. The sensor, the electronics or the disc can be repaired or replaced, and the encoder is aligned to the motor. A damaged disc may need a replacement unit.

Is a different encoder a direct replacement?

Only if the resolution, output type, supply, mounting and commutation tracks match. We check these before any swap.

Why does a new encoder give the wrong direction or count?

A and B wires may be swapped, the line count may differ, or the drive setting may not match. Check the drive manual for the setting.

See also

Star Automations is an independent repair company and not an OEM service partner. Brand names are used only to identify the equipment we repair. The manual for your unit is the authority for exact signals, wiring and settings.