Since 2000 · 3,000+ customers

Home / Encoder and feedback repair / HIPERFACE encoder

Feedback devices · HIPERFACE

HIPERFACE encoder repair and fault diagnosis

A HIPERFACE encoder from Sick-Stegmann gives analog sine and cosine signals for fine speed and position, plus a serial link for absolute position and data. Star Automations repairs these encoders, checks both the analog and the serial signals, and arranges exchange or retrofit. Send the nameplate.

  • 25+years of servo repair, since 2000
  • 3,000+customers across India
  • 100+servo brands covered by our universal servo motor test equipment
  • 5sites: Puducherry, Chennai, Bengaluru, Hyderabad, Delhi

Every repaired unit returns with a printed test report.

How a repair starts

Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment.

Every repaired unit is tested on our bench and returns with a printed test report. Timing depends on the fault and the parts, and is stated on the quote.

  • Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment
  • Printed test report with every motor
  • Every repair carries a warranty; terms are on the quote.
  • Pickup can be arranged; parts that must be imported are quoted with their own timeline
01Anatomy

How a HIPERFACE encoder works and where it fails

The drive uses the sine and cosine signals for speed and fine position, and the serial link for the absolute position at power-up. Either part can fail, so both are checked.

HIPERFACE encoder signal pathSignal path from the sensing element to the drive. Numbers mark the common failure points.Sensor and discPosition source1ElectronicsSignals and serial link2Cable and connectorAnalog and serial3DriveReads both4
  1. Sensor and disc: The disc and sensor make sine and cosine and read the absolute value.
  2. Electronics: The board makes the analog signals and the serial data. Ageing parts give errors.
  3. Cable and connector: Several pairs carry the signals. A break or noise on one pair gives an error.
  4. Drive: The drive reads both the signals and the serial position. A wrong setting gives an alarm.
02Types

Types, makers and where they are used

TypeNotesWhere it is used
Single-turnAbsolute position in one turnServo motors
Multi-turnAbsolute position over many turnsAxes with long travel
HIPERFACE DSLOne-cable digital versionNewer motors
03Faults

Fault symptoms, causes and safe checks

Tap a symptom for the likely causes and the safe checks. Switch off and lock out before touching any wiring.

Encoder communication fault at power-up

Likely causes: The serial link is broken, the supply is missing, or the electronics are damaged.

Safe checks: With the supply off, check the cable and the connector, then the supply at the encoder end.

Speed ripple or vibration

Likely causes: Sine and cosine signals are distorted, or the amplitude is low.

Safe checks: Compare the sine and cosine signals on an oscilloscope with a known good unit.

Position error after power-up

Likely causes: The absolute value read does not match the analog position.

Safe checks: Check the serial and analog signals together. A mismatch points to the encoder.

Alarm when hot

Likely causes: Electronics drift with heat.

Safe checks: Check at cold and warm temperature on the bench.

04Diagnosis

Diagnosis flow: find the fault in five steps

Diagnosis flowFive steps to find the fault, from the cable to the sensing element.1
Check supply and cable at the encoder end
2
Inspect connector and shield
3
Scope the output signals
4
Compare with a known good unit
5
Repair, align or replace

Most feedback faults sit in the cable, the connector or the supply, not in the sensing element. Check those first.

05Alternatives

Not repairable or not available? Your options

When a HIPERFACE encoder cannot be repaired or is no longer sold, there are five routes.

RouteWhat it means here
RepairRepair and test the HIPERFACE encoder on our encoder test setup, and re-align it to the motor.
ExchangeA tested unit of the same type, with the output matched to your drive.
SourcingThe exact part through our offices and partners abroad, then tested.
RetrofitA current encoder with the same output, resolution and mounting, or an adapter. The drive must support it, and the commutation angle is set again.
Board rebuildIf the encoder or its electronics are obsolete, we reverse-engineer and rebuild the board.

More on replacement options

→How it works

From nameplate photo to a tested motor in 7 steps

One route for servo motors, encoders and drives. You see the price before any work starts, and the report before the unit leaves our bench.

  1. 1 · Nameplate photoSend it on WhatsApp or the form
  2. 2 · Repairable? QuoteWe assess the nameplate photo and confirm whether the unit is repairable.
  3. 3 · Courier or pickupThe unit reaches our bench
  4. 4 · Bench diagnosisInsulation, windings, brake, encoder
  5. 5 · RepairFailed parts, bearings, seals, brake
  6. 6 · Align and run-testEncoder aligned; no-load and load run
  7. 7 · Report and dispatchPrinted test report with the unit
  8. Line down?Servo Swap ships a tested unit first. How Servo Swap works

Timing depends on the fault and the parts, and is stated on the quote.

06FAQ

Frequently asked questions

What is HIPERFACE?

HIPERFACE is an encoder interface from Sick-Stegmann that combines analog sine and cosine signals with a serial link for absolute position and encoder data.

Can a HIPERFACE encoder be repaired?

Often yes. We repair the electronics and the bearings, check both the analog and serial signals, and align the encoder to the motor.

Which drives use HIPERFACE?

Many servo drives from several makers support it. Check the drive manual for the supported feedback types.

Can I use another encoder instead?

Only if the drive supports its interface and the resolution, supply and mounting match.

See also

Star Automations is an independent repair company and not an OEM service partner. Brand names are used only to identify the equipment we repair. The manual for your unit is the authority for exact signals, wiring and settings.