The ACS580-01-12A7-4 is an ABB ACS580 general purpose drive used on pumps, fans and conveyors. Star Automations sources and supplies the ACS580-01-12A7-4 and repairs failed units at component level, so you can choose between a replacement and getting your existing unit restored. This is a current OEM line. Availability and price are confirmed per enquiry. Most quotes come back the same day — send the part number or the fault code on WhatsApp.

Common ACS580 fault codes and what we usually find
Fault code wording can differ by firmware and manual revision — always confirm against the manual for your exact unit. The causes below are typical findings, not a diagnosis of your specific unit.
| Code | Meaning | Typical cause |
|---|---|---|
| 2310 | OVERCURRENT | Short circuit, motor or cable fault, too-short acceleration time |
| 2330 | EARTH LEAKAGE | Motor or cable insulation failure |
| 2340 | SHORT CIRCUIT | Output short, failed IGBT |
| 3130 | INPUT PHASE LOSS | Missing supply phase, loose terminal, blown input fuse |
| 3210 | DC LINK OVERVOLTAGE | Fast deceleration, regenerative load, no braking resistor |
| 3220 | DC LINK UNDERVOLTAGE | Low supply, dropped phase, failed charging circuit |
| 4210 | IGBT OVERTEMPERATURE | Blocked airflow, failed fan, high ambient |
| 4310 | EXCESS TEMPERATURE | Cooling problem, high ambient temperature |
When a ACS580-01-12A7-4 needs attention
- Drive trips on overcurrent or undervoltage
- Fan noise or overheating
- No display or no power-up
- Burnt smell or damaged power stage
- Trips under load
Replace or repair your ACS580-01-12A7-4
Source a replacement
Send the part number. We check sourcing from global surplus and the OEM channel and reply the same day with availability, condition and price. Advance or verified escrow applies.
Repair your existing unit
If sourcing takes longer or you want to keep your configuration, we repair at component level — power stage, gate-drive, control and supply sections — and test before dispatch.
What people look up for the ACS580-01-12A7-4
- ACS580-01-12A7-4 repair
- ACS580-01-12A7-4 price India
- ABB ACS580 fault 2310
- ABB ACS580 fault 3220
- ABB ACS580 drive repair
- ABB ACS580 replacement
ACS580-01-12A7-4 — common questions
Can you supply the ACS580-01-12A7-4 in India?
Can a faulty ACS580-01-12A7-4 be repaired instead of replaced?
My ACS580-01-12A7-4 shows 2310 (overcurrent). What should I do?
Is the exact part number important?
Need the ACS580-01-12A7-4 now?
Send the part number or fault code — we reply the same day. Serving Chennai, Puducherry, Bengaluru, Hyderabad, Delhi and pan-India.