MCB, MCCB and MPCB: types, differences and supply by part number

Updated November 2026

Short answer:** Star Automations supplies miniature circuit breakers (MCB), moulded case circuit breakers (MCCB) and motor protection circuit breakers (MPCB) for industrial panels, by part number. Supplied new, surplus or refurbished on request, subject to availability.

01 MCB vs MCCB vs MPCB

MCBMCCBMPCB
Used forFinal circuits, control and lighting circuitsFeeders, incomers and larger loadsIndividual motors
Current rangeLow currents, up to the maker's MCB rangeHigher currents than an MCBMotor currents, set to the motor full-load current
Trip settingFixedFixed or adjustable, by modelAdjustable thermal setting with magnetic trip
Typical standardIEC 60898-1 or IEC 60947-2IEC 60947-2IEC 60947-2 and IEC 60947-4-1

The exact current and breaking capacity are on the breaker label and the maker's catalogue; quote them when you order.

02 Types of MCB by trip curve

CurveMagnetic trip (multiple of rated current, IEC 60898-1)Typical load
B3 to 5 timesResistive loads, lighting, long cables
C5 to 10 timesGeneral panels, small motors, transformers
D10 to 20 timesHigh inrush loads such as large transformers and motors

MCBs also differ by poles (1P, 1P+N, 2P, 3P, 4P), rated current and breaking capacity in kA.

03 What to send for a quote

  • The full part number from the front label.
  • Rated current, poles and curve (MCB), or frame, rated current and trip unit (MCCB), or setting range (MPCB).
  • Breaking capacity in kA and any accessories: auxiliary contact, shunt trip, undervoltage release, rotary handle.
  • Quantity, and a photo if the label is worn.

04 Brands and series we quote

For example Schneider Electric (Acti9, EasyPact, ComPact NSX, TeSys GV2), Siemens (5SL, 5SY, 3VA, 3RV), ABB (S200, Tmax, MS116 and MS132), L&T and others. Send the part number; if a series is discontinued, we suggest a replacement with the same rating, poles and mounting.

Browse listed breakers in the online shop.

06 Frequently asked questions

What is the difference between an MCB and an MCCB?

An MCB protects smaller final circuits and has a fixed trip. An MCCB is built for higher currents, has a higher breaking capacity and, on many models, an adjustable trip unit.

What is an MPCB?

A motor protection circuit breaker protects a single motor. It combines an adjustable thermal overload setting with magnetic short-circuit protection, and is set to the motor full-load current.

What are B, C and D type MCBs?

They are trip curves. Under IEC 60898-1, a B curve trips magnetically at 3 to 5 times rated current, C at 5 to 10 times and D at 10 to 20 times. Higher curves tolerate higher inrush current.

Can I replace an MCCB with another brand?

Often yes, if the rated current, poles, breaking capacity, trip type and mounting match, and the accessories and busbar or cable connections fit. Send both part numbers and we check.

How do I order an MCB or MCCB?

Send the part number, rating, poles and quantity with a photo of the label on WhatsApp or through the parts request form. Supplied new, surplus or refurbished on request, subject to availability.

07 Send the part number for a quote

Share the part number, a clear photo of the label and the quantity. We reply with what we can supply.

Supplied new, surplus or refurbished on request, subject to availability.

Service locations: Puducherry, Chennai, Bengaluru, Hyderabad and Delhi.

ISO 9001:2015 · 3,000+ customers · 100+ brands · 100+ engineers · GeM vendor · universal servo test system for 180+ motor models.

*Brand names and part numbers are trademarks of their owners and are used only to identify compatible products; Star Automations is an independent supplier and repair provider.*