Hydraulic valve repair
Hydraulic servo and proportional valve repair in India
Star Automations repairs hydraulic servo and proportional valves and their drive electronics in India. We check the amplifier card, coils and position feedback, find whether the fault is electrical or hydraulic, and test the valve on the bench. Send the valve label and the fault description on WhatsApp.
How a servo or proportional valve works and where it fails
A servo or proportional valve turns a small electrical command into oil flow. An amplifier card drives a coil or torque motor, a spool moves, and a feedback sensor reports the spool position back to the amplifier. Faults gather in three places: the amplifier card, the coil and feedback sensor, and the spool and oil.
- Amplifier card: drives the coil. A failed output stage or supply fault stops the valve responding.
- Coil or torque motor: open or shorted windings give weak or no movement.
- Position feedback (LVDT): a bad signal makes the valve drift or hunt.
- Spool and oil: contamination makes the valve stick or lose control.
Star is an independent repair company, not an OEM service partner.
Valve parts, typical faults and what we do
| Item | Typical fault | What we do |
|---|---|---|
| Valve amplifier card | No response, hunting | Component-level repair and bench test |
| Proportional valve coil | Weak or no movement | Coil check and replacement where a part is available |
| LVDT position feedback | Drift, oscillation | Signal check and sensor replacement |
| Servo valve | Sticking, poor control | Inspection and fault diagnosis, with advice on repair or replacement |
| Obsolete valve electronics | Card no longer sold | We check whether the card can be repaired, rebuilt or replaced |
Typical machines: injection moulding machines, presses, test rigs and other hydraulic machines with closed-loop motion.
Fault symptoms and safe checks
Isolate hydraulic pressure and electrical supply before touching any valve or wiring.
- Valve does not move: check the supply and the command signal at the amplifier.
- Valve drifts at zero command: suspect the feedback sensor or the amplifier offset.
- Machine hunts or oscillates: suspect the feedback signal or oil contamination.
- Slow or weak response: suspect the coil, the amplifier output or contaminated oil.
- Amplifier alarm: note the code and send it with the valve label.
How we work on a valve
- Send the valve label and the fault description.
- Send the valve and its amplifier card to our bench.
- We check the electronics and the feedback signal.
- We repair the card, coil or sensor.
- We test the response and return the valve.
The plant re-validates the valve in its own machine.
If a valve cannot be repaired
| Route | What it means |
|---|---|
| Repair the original | Replace failed parts at component level and test the unit. |
| Exchange unit | A tested unit from our stock where one is available. |
| Retrofit replacement | A new part mounted to fit the old position, or a hydraulic to servo retrofit. |
| Source abroad | Sourcing through our offices and partners abroad. |
Frequently asked questions
Do you repair hydraulic servo valves?
Yes. We repair hydraulic servo and proportional valves and their amplifier cards, and test them on the bench.
What do you check first?
The amplifier card, the coil and the position feedback, to find whether the fault is electrical or in the valve itself.
Which valve makes do you repair?
Send the valve label. We confirm whether we can test and repair that model before you ship.
Do you repair the whole hydraulic power unit?
This page covers valves and their drive electronics. Send the machine details and we will tell you what we can take on.
Is Star an OEM service partner?
No. Star is an independent multi-brand repair company with benches in Puducherry, Chennai and Bengaluru.