Since 2000 · 3,000+ customers

Home / Hydraulic servo valve repair

Hydraulic valve repair

Hydraulic servo and proportional valve repair in India

Star Automations repairs hydraulic servo and proportional valves and their drive electronics in India. We check the amplifier card, coils and position feedback, find whether the fault is electrical or hydraulic, and test the valve on the bench. Send the valve label and the fault description on WhatsApp.

01Anatomy

How a servo or proportional valve works and where it fails

A servo or proportional valve turns a small electrical command into oil flow. An amplifier card drives a coil or torque motor, a spool moves, and a feedback sensor reports the spool position back to the amplifier. Faults gather in three places: the amplifier card, the coil and feedback sensor, and the spool and oil.

  • Amplifier card: drives the coil. A failed output stage or supply fault stops the valve responding.
  • Coil or torque motor: open or shorted windings give weak or no movement.
  • Position feedback (LVDT): a bad signal makes the valve drift or hunt.
  • Spool and oil: contamination makes the valve stick or lose control.

Star is an independent repair company, not an OEM service partner.

02Types

Valve parts, typical faults and what we do

ItemTypical faultWhat we do
Valve amplifier cardNo response, huntingComponent-level repair and bench test
Proportional valve coilWeak or no movementCoil check and replacement where a part is available
LVDT position feedbackDrift, oscillationSignal check and sensor replacement
Servo valveSticking, poor controlInspection and fault diagnosis, with advice on repair or replacement
Obsolete valve electronicsCard no longer soldWe check whether the card can be repaired, rebuilt or replaced

Typical machines: injection moulding machines, presses, test rigs and other hydraulic machines with closed-loop motion.

03Faults

Fault symptoms and safe checks

Isolate hydraulic pressure and electrical supply before touching any valve or wiring.

  • Valve does not move: check the supply and the command signal at the amplifier.
  • Valve drifts at zero command: suspect the feedback sensor or the amplifier offset.
  • Machine hunts or oscillates: suspect the feedback signal or oil contamination.
  • Slow or weak response: suspect the coil, the amplifier output or contaminated oil.
  • Amplifier alarm: note the code and send it with the valve label.
04Flow

How we work on a valve

  1. Send the valve label and the fault description.
  2. Send the valve and its amplifier card to our bench.
  3. We check the electronics and the feedback signal.
  4. We repair the card, coil or sensor.
  5. We test the response and return the valve.

The plant re-validates the valve in its own machine.

05Alternatives

If a valve cannot be repaired

RouteWhat it means
Repair the originalReplace failed parts at component level and test the unit.
Exchange unitA tested unit from our stock where one is available.
Retrofit replacementA new part mounted to fit the old position, or a hydraulic to servo retrofit.
Source abroadSourcing through our offices and partners abroad.
06FAQ

Frequently asked questions

Do you repair hydraulic servo valves?

Yes. We repair hydraulic servo and proportional valves and their amplifier cards, and test them on the bench.

What do you check first?

The amplifier card, the coil and the position feedback, to find whether the fault is electrical or in the valve itself.

Which valve makes do you repair?

Send the valve label. We confirm whether we can test and repair that model before you ship.

Do you repair the whole hydraulic power unit?

This page covers valves and their drive electronics. Send the machine details and we will tell you what we can take on.

Is Star an OEM service partner?

No. Star is an independent multi-brand repair company with benches in Puducherry, Chennai and Bengaluru.