Home / Encoder and feedback repair / Injection moulding machine feedback faults

Feedback devices · Industry

Injection moulding machine encoder and linear transducer faults

Injection moulding machines use servo motor encoders and linear position transducers for clamp, injection and ejector. Heat, oil and moving cables are the main causes of faults. Star Automations repairs servo encoders and position sensors for moulding machines, and arranges exchange or retrofit. Send the machine make, the alarm and the nameplate.

  • 26years of servo repair, since 2000
  • 3,000+customers across India
  • 100+servo brands covered by our universal servo motor test equipment
  • 5sites: Puducherry, Chennai, Bengaluru, Hyderabad, Delhi

Every repaired unit returns with a printed test report.

How a repair starts

Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment.

Every repaired unit is tested on our bench and returns with a printed test report. Timing depends on the fault and the parts, and is stated on the quote.

  • Send the nameplate photo on WhatsApp +91 97866 22233 for a repair assessment
  • Printed test report with every motor
  • Every repair carries a warranty; terms are on the quote.
  • Pickup can be arranged; parts that must be imported are quoted with their own timeline
01Anatomy

How a injection moulding feedback system works and where it fails

Servo pumps and motors have encoders or resolvers, and linear transducers measure screw, clamp and ejector positions. They work in heat and oil mist, so seals and cables wear out.

injection moulding feedback system signal pathSignal path from the sensing element to the drive. Numbers mark the common failure points.Servo motor encoderPump or axis motor1Linear transducerScrew and clamp position2CableMoves with the machine3Machine controllerCloses the loop4
  1. Servo motor encoder: Resolver or encoder on the servo motor. Heat ages the electronics.
  2. Linear transducer: Position sensors on the moving parts. Oil and shock cause faults.
  3. Cable: Moving cables break and oil swells the jacket.
  4. Machine controller: Shows a position or feedback alarm.
02Types

Types, makers and where they are used

DeviceWhere fittedFaults seen
Servo motor encoder or resolverServo pump motors, axesHeat alarms, noise, bearing wear
Linear transducerClamp, injection and ejectorSignal loss, oil, shock damage
Rotary encoderScrew drive and plasticisingPulse loss, noise
03Faults

Fault symptoms, causes and safe checks

Tap a symptom for the likely causes and the safe checks. Switch off and lock out before touching any wiring.

Servo feedback alarm after the machine warms up

Likely causes: Electronics drift with heat, or oil in the connector.

Safe checks: Check the connector and the cable. Note the temperature when the alarm comes.

Position reading jumps or shot size varies

Likely causes: Noise on a transducer, or a damaged sensor.

Safe checks: Check the shield and ground and the transducer output.

Axis alarm at one point in the stroke

Likely causes: A cracked wire in a moving cable.

Safe checks: Check the cable along its full movement with the supply off.

Fault after a motor change

Likely causes: The encoder was not aligned to the motor.

Safe checks: Align the encoder to the motor.

04Diagnosis

Diagnosis flow: find the fault in five steps

Diagnosis flowFive steps to find the fault, from the cable to the sensing element.1
Read the alarm and note the device type
2
Check supply, cable and connector
3
Check the signals or serial link
4
Compare with a known good unit
5
Repair, align or replace

Most feedback faults sit in the cable, the connector or the supply, not in the sensing element. Check those first.

05Alternatives

Not repairable or not available? Your options

When a injection moulding feedback system cannot be repaired or is no longer sold, there are five routes.

RouteWhat it means here
RepairRepair and test the feedback device on our encoder test setup, and align it to the motor.
ExchangeA tested unit of the same type, with the output matched to your drive.
SourcingThe exact part through our offices and partners abroad, then tested.
RetrofitA current device with the same interface, resolution and mounting, or an adapter, matched to the injection moulding machine. The drive must support it, and the commutation angle is set again.
Board rebuildIf the device or its electronics are obsolete, we reverse-engineer and rebuild the board.

More on replacement options

→How it works

From nameplate photo to a tested motor in 7 steps

One route for servo motors, encoders and drives. You see the price before any work starts, and the report before the unit leaves our bench.

  1. 1 · Nameplate photoSend it on WhatsApp or the form
  2. 2 · Repairable? QuoteWe assess the nameplate photo and confirm whether the unit is repairable.
  3. 3 · Courier or pickupThe unit reaches our bench
  4. 4 · Bench diagnosisInsulation, windings, brake, encoder
  5. 5 · RepairFailed parts, bearings, seals, brake
  6. 6 · Align and run-testEncoder aligned; no-load and load run
  7. 7 · Report and dispatchPrinted test report with the unit
  8. Line down?Servo Swap ships a tested unit first. How Servo Swap works

Timing depends on the fault and the parts, and is stated on the quote.

06FAQ

Frequently asked questions

Can you repair servo motor encoders on moulding machines?

Yes, for many makes. We repair and align encoders and resolvers for servo pump motors and axes.

Can a linear transducer be repaired?

Electronics and some parts can be repaired. A damaged sensing element may need replacement.

What causes repeated encoder failures?

Heat, oil and broken moving cables are the main causes. Fixing the cause matters as much as the repair.

What do I send you?

The machine make and model, the alarm and photos of the nameplates.

See also