Since 2000 · 3,000+ customers

India · Line automation, cells, AGVs and machine vision

Machine safety assessment and retrofit for line automation, cells and AGVs

Star Automations checks machine safety and fits the safety hardware for automation lines, cell entrances, AGVs and machine vision systems. A Star engineer works with a functional safety engineer. Risk is rated to ISO 12100, the required performance level is set to ISO 13849, and stop time is measured. We fit safety curtains, safety relays and interlocks. The plant keeps its own safety sign-off.

Four places where we have fitted safety

Where Star Automations fits machine safetyFour applications: safety curtain at a line automation mould point, safety curtain at an automated cell entrance, safety system on AGVs, and safety system on machine vision. All start from one machine safety check.Machinesafety checkLine automationJob placed in or takenfrom a mould: safetycurtain at the openingEntranceSafety curtain at theentrance of anautomated cellAGVSafety system fitted onnew AGVs and retrofittedon older AGVsMachine visionSafety system builtinto a visionapplication
Four places where Star Automations has fitted safety. Each starts from one safety check.
Line automationSafety curtain where a job is placed in or taken from a mould.
Automated cell entranceSafety curtain at the entrance, with the automation wired to stop when it is crossed.
AGVSafety system on new AGVs and retrofitted on older AGVs.
Machine visionSafety system built into a machine vision application.

How the machine safety check works

  1. Safety checkA Star engineer, with a functional safety engineer, walks the machine, cell or AGV.
  2. Risk ratingRisk is rated to ISO 12100. The required performance level is set to ISO 13849.
  3. Stop timeWe measure stop time so the safety distance can be set.
  4. ProposalA written proposal per machine: curtains, relays, interlocks.
  5. InstallWe fit the agreed devices and wiring.
  6. Check and recordsWe check the devices and hand over the records. The plant re-validates the safety function.

What we fit

Safety curtainsFitted at openings, entrances and loading points, with the stop distance set from the measured stop time.
Safety relays and circuitsSafety relay wiring that stops the machine when a safety device is triggered.
InterlocksInterlock wiring as set out in the written proposal for each machine.
AGV safety systemFor new AGVs and for older AGVs that need a safety retrofit.
Machine vision safetySafety system for a vision application on a line or cell.

Hardware is fitted and bench tested by Star. The plant re-validates the safety function on site.

Who should contact us

Plant, maintenance and automation heads who run automated lines, cells or AGVs and want one team for the safety check and the hardware.

  • A new automated line or cell is being commissioned.
  • An older AGV needs a safety system.
  • A line automation setup needs a safety curtain at the mould or the entrance.
  • A vision application needs a safety system.

Machine safety questions

What does Star Automations do for machine safety?

Star Automations checks machine safety and fits the safety hardware for automation lines, cell entrances, AGVs and machine vision systems. A Star engineer works with a functional safety engineer on the check. We fit safety curtains, safety relays and interlocks, check them and hand over the records.

Which standards do you use for the safety check?

The risk is rated to ISO 12100. The required performance level is set to ISO 13849. Stop time is measured so the safety distance can be set. These methods are used in the check and in the written proposal.

Can you fit safety on AGVs?

Yes. We have fitted a safety system on new AGVs and retrofitted one on older AGVs. Send the AGV type, the area it runs in and what safety it has today.

Do you fit safety curtains on automated lines?

Yes. We have fitted safety curtains where a job is placed in or taken from a mould in a line automation setup, and at the entrance of automated cells.

Do you issue a safety certificate for the plant?

No. Star checks the devices it fits and gives you the records, including the measured stop time. The plant re-validates the safety function and keeps its own safety sign-off.

Do you also service the servo motors and drives on the same machines?

Yes. Star Automations repairs multi-brand servo motors, servo drives, AC drives and PLC and control electronics. After a safety retrofit the same team can keep supporting those machines.

See also: servo motor repair and PLC repair.