Since 2000 · 3,000+ customers

Sanyo Denki · E07B111335

Sanyo Denki E07B111335 encoder repair, test and alignment

E07B111335 is a Serial with incremental A, B, Z encoder with 2,048 per turn, ±4,096 revolutions. We test it, repair or replace it and align it to the rotor. Found on: Sanyo Denki servo motors; equivalent to Sumtak AEC2048 and Tamagawa TS5643. Star Automations is an independent multi-brand repair company and is not an OEM service centre.

E07B111335 encoder test
  • 25+years of servo repair, since 2000
  • 3,000+customers across India
  • 100+servo brands covered by our universal servo motor test equipment
  • 5sites: Puducherry, Chennai, Bengaluru, Hyderabad, Delhi
  • Same dayemergency repair option*

*Where the fault and parts allow. Every repaired unit returns with a printed test report.

Repair turnaround you can plan around

Send a photo of the nameplate first. We confirm whether the motor is repairable, and the quote, the same working day.

Emergency: same day

For a line-down motor, where the fault and parts allow. WhatsApp us before you send it so the bench is kept free.

Urgent: 3 working days

Repair, encoder alignment and test, counted from the day the motor reaches the bench and the quote is approved.

Standard: 7 working days

Full repair, encoder alignment, run test under load and a printed test report.

  • Free repairability check from a nameplate photo
  • Printed test report with every motor
  • Written warranty, terms stated on every quotation
  • Pickup can be arranged; parts that must be imported are quoted with their own timeline
01Facts

E07B111335 at a glance

DeviceE07B111335
Brand familySanyo Denki
Type and formatSerial with incremental A, B, Z
Counts2,048 per turn, ±4,096 revolutions
Found onSanyo Denki servo motors; equivalent to Sumtak AEC2048 and Tamagawa TS5643
ConnectorPer motor model
Pole setting for alignmentSet at alignment

The E07B111335 gives 11 bit single-turn resolution (2,048 counts) with 13 bits counting revolutions (±4,096). It also outputs 2,048 pulses (8,192 counts) per turn on A, B and Z. It is essentially the same as the Sumtak AEC2048 and the Tamagawa TS5643.

02Faults

How E07B111335 encoders usually fail

  • No serial data from a board or cable fault
  • Absolute count lost after a battery fault
  • Index or incremental channel missing
  • Alignment that no longer matches the rotor
02+Alarms

E07B111335 alarms and error codes: what they mean and what to check

These are the alarms most often seen with the E07B111335 feedback device, with what each usually means and what to check first. Many encoder alarms are caused by the cable, connector or battery, not the encoder, so the checks below can save a repair.

AlarmUsually meansCheck first
Encoder communication or no-data alarmThe drive receives no serial data from the encoderConnector, cable, supply voltage; then the encoder board
Encoder data or checksum alarmSerial frames arrive corruptedNoise, shield and earthing; then the encoder
Incremental A or B signal alarmThe count and the serial position disagreeCable and connector; then the encoder
Overheat alarm from the encoderTemperature flag setMotor temperature and cooling; stuck flag points to the encoder board
Alarm after a motor or encoder changeMotor data or alignment does not matchCheck the motor type setting and the encoder alignment

Alarm numbers differ between drive series, so the list is by situation rather than number. Match what your alarm text says. Alarm numbers and wording change with drive series and firmware, so check the manual for your drive. Drive brand names are used only to identify alarm lists. Star Automations is an independent multi-brand repair company and is not an OEM service centre.

Typical causes and checks

  • Alarm at every power-up: reseat the connector at both ends, check the encoder supply at the motor end, and look for a broken wire.
  • Alarm only when the axis moves or the cable flexes: suspect a break inside the cable chain, or a shield that has come loose.
  • Alarm after coolant, washdown or rain: look for moisture or corrosion in the connector and behind the encoder cover.
  • Alarm at random with other drives running: check earthing and shield clamps, and keep the feedback cable away from power cables.
  • Alarm after a motor, encoder or drive change: check the type, the motor data in the drive, and the encoder alignment.

Encoder, cable or drive?

Swap in a known-good feedback cable first. If the alarm stays, move the motor to another axis if the drives are the same type. If the alarm follows the motor, the encoder or motor needs testing. If it stays on the axis with a good motor and cable, the drive needs testing. We test the encoder, the motor and the drive, so send the nameplate if you are not sure which it is.

Related guides: Servo encoder alarms, Test a servo motor without the drive.

03Process

How the repair is done

  1. Receive and identify

    We read the nameplate and encoder label and confirm the exact type.

  2. Test

    Count per turn, data status, alarm flags and, where fitted, incremental lines are checked on the bench.

  3. Repair or replace

    Board, connector or sensor faults are repaired; a matched encoder is fitted where repair is not sensible.

  4. Align

    Commutation is set to the rotor and checked at every pole pair using the electrical angle.

  5. Verify and report

    The motor is run on the bench and the readings are recorded in the report.

See encoder alignment, memory programming and replacement.

05FAQ

Questions

What do encoder alarms on a E07B111335 usually mean?

Most fall into four groups: no communication, corrupted data, a fault reported by the encoder itself, and a position or commutation mismatch. The alarm table on this page lists the common codes and the first check for each.

How can I tell whether the E07B111335 encoder, the cable or the drive is at fault?

Swap in a known-good feedback cable, then move the motor to another axis if possible. If the alarm follows the motor, the encoder needs testing; if it stays on the axis, the drive does. A cable or battery fault can be fixed without sending anything.

Can you repair a E07B111335 encoder?

Yes. We test the position count and status, repair or replace the encoder, align it to the rotor and run the motor. We repair Sanyo Denki units; Star Automations is an independent multi-brand repair company and is not an OEM service centre.

What encoders are equivalent?

The Sumtak AEC2048 and the Tamagawa TS5643.

How many turns does it track?

Plus or minus 4,096 revolutions.

What should I send for a E07B111335 enquiry?

A clear photo of the motor nameplate and, if the cover is off, the encoder label. You can send the motor or only the encoder.

06Enquiry

Send the nameplate or encoder label

A clear photo of the motor nameplate and, if the cover is off, the encoder label is enough to start. We reply with whether it can be repaired and a quote.

We use these details to reply to your enquiry. See our privacy policy.

→How it works

From nameplate photo to a tested motor in 7 steps

One route for servo motors, encoders and drives. You see the price before any work starts, and the report before the unit leaves our bench.

  1. 1 · Nameplate photoSend it on WhatsApp or the form
  2. 2 · Repairable? QuoteUsually the same working day
  3. 3 · Courier or pickupThe unit reaches our bench
  4. 4 · Bench diagnosisInsulation, windings, brake, encoder
  5. 5 · RepairFailed parts, bearings, seals, brake
  6. 6 · Align and run-testEncoder aligned; no-load and load run
  7. 7 · Report and dispatchPrinted test report with the unit
  8. Line down?Servo Swap ships a tested unit first. How Servo Swap works

EmergencySame day*

Urgent3 working days

Standard7 working days

*Where the fault and parts allow. Turnaround counts from when the unit reaches our bench and the quote is approved.