Since 2000 · 3,000+ customers

Quality · Documentation

Sample servo motor test report

Every motor Star Automations refurbishes goes back with a printed test report like this one. It records the motor's identity, inward condition, findings, work done, each test with its method and acceptance criterion, the measured result and a sign-off, so a plant or OEM can accept the unit on evidence.

This is a format sample. All values are illustrative and do not come from a customer's unit. Acceptance criteria follow the OEM's specification or what is agreed with the customer.

Sample report

SAMPLE FORMAT · ILLUSTRATIVE VALUES · NOT A CUSTOMER RECORD
Star Automations
Servo Motor Test ReportRefurbishment and repair-return · Chennai servo bench
Report no.
STR-PDY-SAMPLE-0001
Job no.
PDY-SAMPLE-0001
Issued
[DATE]
Page
1 of 1

1Customer and job

Customer[Redacted]
Customer ref. / PO[Redacted]
ProgrammePlant repair-return
Received[DATE]
Dispatched[DATE]
PriorityLine-down

2Unit identification

TypeAC servo motor, permanent magnet
Make / model[Redacted]
Serial no.[Redacted] · logged at inward
Rated output1.5 kW
Rated speed3,000 rpm
Rated torque / current4.8 N·m / 9.2 A
FeedbackSerial absolute encoder
Brake24 V DC holding brake

3Inward inspection and complaint

Reported faultEncoder alarm at power-up; noise at speed
Housing and shaftNo damage. Keyway OK
SealsFront oil seal worn, oil traces inside
ConnectorsFeedback connector contaminated
Inward photos6 photos on file

4Findings and work done

ItemFindingAction
EncoderNo serial communicationReplaced with equivalent. Commutation offset aligned
BearingsFront bearing noisyFront and rear bearings replaced
Front oil sealWorn, allowing oil ingressReplaced. Interior cleaned
BrakeReleases and holdsTested. No action
WindingsInsulation, hi-pot and balance within limitsNo action
Feedback connectorContaminatedCleaned and re-tested

5Test results

#TestMethodAcceptance criterion (example)MeasuredResult
5.1Insulation resistance, winding to frame500 V DC insulation tester≥ 100 MΩ> 2,000 MΩPASS
5.2Dielectric withstand (hi-pot), winding to frameAC hi-pot tester, 60 s, voltage per OEM specificationNo breakdown; leakage below set limit1,500 V AC · 1.2 mAPASS
5.3Winding resistance, U-V / V-W / W-U4-wire milliohm meter, corrected to 20 °CBalance within ±3%1.12 / 1.13 / 1.12 ΩPASS
5.4Winding inductance balanceLCR meter, 1 kHzBalance within ±5%4.6 / 4.7 / 4.6 mHPASS
5.5Back-EMF constant, line to lineMotor driven at constant speedWithin ±5% of rated+1.2% of ratedPASS
5.6Encoder communication and positionUniversal servo test system, full rotationNo communication errors; position consistent0 errorsPASS
5.7Commutation offsetElectrical angle against back-EMFWithin ±2° electrical0.6°PASS
5.8Holding brakeRelease voltage and holding checkReleases at ≤ 90% rated voltage; holds rated torqueReleases at 19.8 VPASS
5.9No-load run testUniversal servo drive, rated speed, both directionsSmooth rotation; current within limit1.1 APASS
5.10Load testCustom-built load rig, rated torque until temperature is stableTemperature rise within insulation class limitΔT 38 KPASS
5.11VibrationVelocity, RMS, at rated speed≤ 1.8 mm/s0.9 mm/sPASS
5.12Shaft runoutDial gauge at shaft end≤ 0.02 mm0.01 mmPASS

6Result and failure feedback

PASS

Root cause. Worn front oil seal let oil reach the encoder and the feedback connector, causing the encoder failure.

Recommendation. Check oil or coolant spray at the motor's mounting position. Inspect the seal at the next planned maintenance.

7Traceability and sign-off

Parts replacedEncoder, 2 bearings, oil seal · part and lot nos. on file
Test instrumentsCalibrated · IDs and due dates on file
WarrantyAs stated on the quotation
Tested by[Name] · Test engineer
Checked by[Name] · Quality
Date[DATE]
Star Automations · Plot No. 48, Cauvery Nagar, Madhiravedu, Poonamallee, Chennai 600077, India
01For OEMs

Your format, your criteria

For OEM and EV programmes, Star works to your test methods, acceptance criteria and reporting. The report can carry your part numbers, failure codes and warranty fields, and be shared per unit by serial number.

OEM partner programme

Send the motor nameplate.