Since 2000 · 3,000+ customers

Bengaluru · Electronic load testing

Data-Centre and Telecom PSU Load Testing in Bengaluru

Star Automations load-tests server and telecom power supply modules, DC power shelves and DC-DC converters rail by rail in Bengaluru, within the rating of our electronic load. Each module gets a test record.

Important: This is an in-house electrical test and test record service for pre-compliance, production, validation and post-repair testing. It is not NABL-accredited testing, and it is not BIS or CE certification. Our records do not replace a certified laboratory's report. For accredited certification, please use a NABL- or BIS-recognised laboratory.

01Details

What we test

  • Server power supply modules
  • Telecom power supply modules and rectifiers
  • DC power shelves and DC-DC converters

Each rail is loaded at set conditions. We record the measured voltage, current and power, and report pass or fail against the limits you give us.

02Details

Rail-by-rail loading and protection checks

Multi-rail modules are tested one rail at a time, then together where the module and our load allow. Protection checks are done on request. Incoming inspection and post-repair checks use the same method, so records are comparable.

03Details

Scope and limits

Scope and limits
In scopeOut of scope
PSU modules, DC power shelves and converters within our load's ratingRack-level or room-level load banks
Incoming inspection and post-repair checksGenerator testing
Insulation checks on PDUs and power cords through our hipot serviceCommissioning sign-off
04Process

How it works

  1. Send the details

    Product type, quantity, rated voltage, current and power, and your limits. Ship samples to us or book an on-site visit in Bengaluru.

  2. Agree the test plan

    We confirm in writing the load mode, set values, duration and connections, and tell you if your product is outside our load's range.

  3. Test

    Trained staff run each unit in a supervised area and log it individually.

  4. Receive the record

    You get set conditions, measured values and a pass or fail result for each unit.

05Record

What you receive

A test record (PDF) that lists, for each unit: the unit ID, the load mode and set values, the duration, the measured voltage, current and power, a pass or fail result against your limits, and the instrument model used, test date and operator name. Logged data and photos can be added on request.

06Questions

Frequently asked questions

Can you test data-centre power supplies?

We can load-test server and telecom power supply modules, DC power shelves and similar parts rail by rail, within the rating of our electronic load. We do not perform rack-level or room-level load bank testing, generator testing or commissioning sign-off. Share the module's rated output so we can confirm feasibility.

Can you test a PSU after repair?

Yes. We load each rail at set conditions and issue a record for each module. It is a bench check within our load's rating, not a type test. Send the module's rated output on each rail so we can confirm it is in range.

Can you test insulation on PDUs and power cords?

Yes, through our hipot and insulation resistance service, which is separate from load testing. Both services can be quoted for the same batch. Send the product type and quantity and we agree a test plan for each.

—Enquiry

Get a test plan

Tell us what you need to test: product, quantity, rated voltage, current and power, and your limits or specification.

WhatsApp: +91 97866 22233. Website: www.starautomations.com. Address: 1st Floor, 40, Goshala Rd, Garudachar Palya, Mahadevapura, Bengaluru, Karnataka 560048.

See our privacy policy.

Star Automations provides in-house testing and test records. We are not a NABL-accredited or BIS-recognised laboratory. Star Automations is an independent multi-brand repair company and is not an OEM service centre.