Since 2000 · 3,000+ customers

Yaskawa · Yaskawa ABZ and UVW incremental

Yaskawa ABZ and UVW incremental encoder repair

Yaskawa ABZ and UVW incremental is a Quadrature incremental with U, V, W commutation encoder with various counts per turn. We test it, repair or replace it and align it to the rotor. Found on: Yaskawa and Allen-Bradley 8500 series digital servo motors. Star Automations is an independent multi-brand repair company and is not an OEM service centre.

Yaskawa ABZ and UVW incremental encoder test
  • 25+years of servo repair, since 2000
  • 3,000+customers across India
  • 100+servo brands covered by our universal servo motor test equipment
  • 5sites: Puducherry, Chennai, Bengaluru, Hyderabad, Delhi
  • Same dayemergency repair option*

*Where the fault and parts allow. Every repaired unit returns with a printed test report.

Repair turnaround you can plan around

Send a photo of the nameplate first. We confirm whether the motor is repairable, and the quote, the same working day.

Emergency: same day

For a line-down motor, where the fault and parts allow. WhatsApp us before you send it so the bench is kept free.

Urgent: 3 working days

Repair, encoder alignment and test, counted from the day the motor reaches the bench and the quote is approved.

Standard: 7 working days

Full repair, encoder alignment, run test under load and a printed test report.

  • Free repairability check from a nameplate photo
  • Printed test report with every motor
  • Written warranty, terms stated on every quotation
  • Pickup can be arranged; parts that must be imported are quoted with their own timeline
01Facts

Yaskawa ABZ and UVW incremental at a glance

DeviceYaskawa ABZ and UVW incremental
Brand familyYaskawa
Type and formatQuadrature incremental with U, V, W commutation
Countsvarious counts per turn
Found onYaskawa and Allen-Bradley 8500 series digital servo motors
ConnectorPer motor model
Pole setting for alignmentSet at alignment

This is the common Yaskawa quadrature encoder with U, V and W commutation channels. Part numbers are often not clearly marked on the encoder boards, so the signal lines in the cable help identify it.

02Faults

How Yaskawa ABZ and UVW incremental encoders usually fail

  • Missing or weak A, B or Z channel
  • Signal level outside range
  • Dirty or damaged disc
  • Commutation lines that no longer match the rotor
02+Alarms

ABZ and UVW incremental alarms and error codes: what they mean and what to check

These are the alarms most often seen with the ABZ and UVW incremental feedback device, with what each usually means and what to check first. Many encoder alarms are caused by the cable, connector or battery, not the encoder, so the checks below can save a repair.

AlarmUsually meansCheck first
A.C1Servo runaway: the motor turns away from the command, often a wrong phase or encoder alignmentCheck the encoder and motor phase wiring; encoder alignment
A.C2Phase detection error: the commutation signals are invalidEncoder alignment and the cable
A.C3Phase A or B line disconnectedCable and connector, then the encoder
A.C4Phase C (index) line disconnectedCable and connector, then the encoder
A.d0Position error overflowCan follow lost encoder counts; check the encoder signal, then the mechanics and gains

Alarm numbers differ slightly between Sigma generations and Allen-Bradley 8500 drives. Alarm numbers and wording change with drive series and firmware, so check the manual for your drive. Drive brand names are used only to identify alarm lists. Star Automations is an independent multi-brand repair company and is not an OEM service centre.

Typical causes and checks

  • Alarm at every power-up: reseat the connector at both ends, check the encoder supply at the motor end, and look for a broken wire.
  • Alarm only when the axis moves or the cable flexes: suspect a break inside the cable chain, or a shield that has come loose.
  • Alarm after coolant, washdown or rain: look for moisture or corrosion in the connector and behind the encoder cover.
  • Alarm at random with other drives running: check earthing and shield clamps, and keep the feedback cable away from power cables.
  • Alarm after a motor, encoder or drive change: check the type, the motor data in the drive, and the encoder alignment.

Encoder, cable or drive?

Swap in a known-good feedback cable first. If the alarm stays, move the motor to another axis if the drives are the same type. If the alarm follows the motor, the encoder or motor needs testing. If it stays on the axis with a good motor and cable, the drive needs testing. We test the encoder, the motor and the drive, so send the nameplate if you are not sure which it is.

Related guides: Yaskawa A.810 alarm, Yaskawa A.C90 alarm, Servo encoder alarms.

03Process

How the repair is done

  1. Receive and identify

    We read the nameplate and encoder label and confirm the exact type.

  2. Test

    Count per turn, data status, alarm flags and, where fitted, incremental lines are checked on the bench.

  3. Repair or replace

    Board, connector or sensor faults are repaired; a matched encoder is fitted where repair is not sensible.

  4. Align

    Commutation is set to the rotor and checked at every pole pair using the electrical angle.

  5. Verify and report

    The motor is run on the bench and the readings are recorded in the report.

See encoder alignment, memory programming and replacement.

05FAQ

Questions

What do encoder alarms on a ABZ and UVW incremental usually mean?

Most fall into four groups: no communication, corrupted data, a fault reported by the encoder itself, and a position or commutation mismatch. The alarm table on this page lists the common codes and the first check for each.

How can I tell whether the ABZ and UVW incremental encoder, the cable or the drive is at fault?

Swap in a known-good feedback cable, then move the motor to another axis if possible. If the alarm follows the motor, the encoder needs testing; if it stays on the axis, the drive does. A cable or battery fault can be fixed without sending anything.

Can you repair a Yaskawa ABZ and UVW incremental encoder?

Yes. We test the position count and status, repair or replace the encoder, align it to the rotor and run the motor. We repair Yaskawa units; Star Automations is an independent multi-brand repair company and is not an OEM service centre.

How is it tested?

As a quadrature incremental encoder, with the U, V and W lines checked against the rotor.

Is it used on Allen-Bradley motors?

Yes, on Allen-Bradley 8500 series digital servo motors.

What should I send for a Yaskawa ABZ and UVW incremental enquiry?

A clear photo of the motor nameplate and, if the cover is off, the encoder label. You can send the motor or only the encoder.

06Enquiry

Send the nameplate or encoder label

A clear photo of the motor nameplate and, if the cover is off, the encoder label is enough to start. We reply with whether it can be repaired and a quote.

We use these details to reply to your enquiry. See our privacy policy.

→How it works

From nameplate photo to a tested motor in 7 steps

One route for servo motors, encoders and drives. You see the price before any work starts, and the report before the unit leaves our bench.

  1. 1 · Nameplate photoSend it on WhatsApp or the form
  2. 2 · Repairable? QuoteUsually the same working day
  3. 3 · Courier or pickupThe unit reaches our bench
  4. 4 · Bench diagnosisInsulation, windings, brake, encoder
  5. 5 · RepairFailed parts, bearings, seals, brake
  6. 6 · Align and run-testEncoder aligned; no-load and load run
  7. 7 · Report and dispatchPrinted test report with the unit
  8. Line down?Servo Swap ships a tested unit first. How Servo Swap works

EmergencySame day*

Urgent3 working days

Standard7 working days

*Where the fault and parts allow. Turnaround counts from when the unit reaches our bench and the quote is approved.