Since 2000 · 3,000+ customers

Bengaluru · Battery drain and charger testing

Charger and Charging-IC Testing in Bengaluru

Star Automations tests chargers and charging circuits against a simulated discharged battery in Bengaluru, and records charge current, termination and protection behaviour. The charger output must fit within 15 V and our current ratings.

Important: This is an in-house electrical test and test record service for design checks, production, validation and post-repair testing. It is not NABL-accredited testing, and it is not BIS, CE, AIS-140 or RF certification. Our records do not replace a certified laboratory's report. For accredited certification, please use a NABL- or BIS-recognised laboratory.

01Details

How a battery and charger simulator tests a charger

One channel acts as a discharged battery that sinks current. A second channel can act as the charger source. We step the battery voltage across a range and record how the charger or charging circuit responds.

02Details

Charge current and termination behaviour

  • Charge current at each battery voltage point you specify
  • Charge termination behaviour as the simulated battery voltage rises
  • Protection behaviour within range, such as current limit action
03Details

Power banks and adapters

Power bank and adapter outputs can be checked for output voltage and current delivery under a set load, within the sink rating of the simulator.

04Details

Chargers up to 15 V, and what is out of range

Scope of charger testing
In scopeOut of scope
Chargers and charging circuits with output inside 15 V and our current ratingsChargers above 15 V, such as e-bike or EV chargers
Charge current, termination and protection checksCycle-life, thermal and abuse testing
A record for each unitBIS or other certification

Also test insulation before dispatch with our hipot and insulation resistance testing service.

05Process

How it works

  1. Send the details

    Product type, quantity, battery voltage, expected current in each state, and your limits. Ship samples to us or book an on-site visit in Bengaluru.

  2. Agree the test plan

    We confirm in writing the supply voltage and output resistance, the device states, the duration, the limits and the connections, and tell you if your product is outside our range.

  3. Test

    Trained staff run each unit in a supervised area and log it individually.

  4. Receive the record

    You get set conditions, measured values, a graph or log where available, and a pass or fail result for each unit.

06Record

What you receive

A test record (PDF) that lists, for each unit: the unit ID, the supply conditions, the measured values, the graph or data file where available, a pass or fail result against your limits, and the instrument model used, test date and operator name. Logged data and photos can be added on request. We run the test you specify. We do not interpret compliance with a standard for you.

07Questions

Frequently asked questions

Can you test chargers and charging circuits?

Yes, within range. The battery channel acts as a discharged battery that sinks current, while the second channel can act as the charger source, so we can test chargers and charging circuits over a range of battery voltages and record the results. The charger output must fit within 15 V and our current ratings.

What are your voltage limits for charger testing?

Our instruments source up to 15 V, so the charger output must be within 15 V and our current ratings. Anything above 15 V, such as e-bike or EV chargers, is outside our range. We tell you before any work starts if a charger is out of range.

Do you test power banks and adapters?

Yes, within the sink rating of the simulator. We check output voltage and current delivery under a set load and record the results for each unit. Send the rated output so we can confirm the unit is within range before agreeing a test plan.

—Enquiry

Get a test plan

Tell us what you need to test: product, quantity, battery voltage, expected current in each state, and your limits or specification.

WhatsApp: +91 97866 22233. Website: www.starautomations.com. Address: 1st Floor, 40, Goshala Rd, Garudachar Palya, Mahadevapura, Bengaluru, Karnataka 560048.

See our privacy policy.

Star Automations provides in-house testing and test records. We are not a NABL-accredited or BIS-recognised laboratory. Star Automations is an independent multi-brand repair company and is not an OEM service centre.