MicroLogix 1000, 1100, 1200 and 1400 to Micro800 migration

Star Automations migrates MicroLogix controllers to Micro800 (programmed in Connected Components Workbench) or, for the MicroLogix 1500, to CompactLogix. We review the program, I/O and communications, rebuild the logic and test it before cutover, and supply MicroLogix spares while you plan.

Industrial automation drives and spares at Star Automations
01What moves to what

Typical migration paths

The right target depends on your I/O count, networks, performance needs and budget. We confirm the target during the audit — the table shows the usual direction, not a fixed rule.

LegacyTypical targetWhat to watch
MicroLogix 1000 / 1100 / 1200Micro800 (Micro820 / 830 / 850)Different software: Connected Components Workbench
MicroLogix 1400Micro800Check I/O count and Ethernet needs
MicroLogix 1500CompactLogixLarger system; Studio 5000
02Technical points

What needs care in this migration

Software change

Micro800 uses Connected Components Workbench and IEC 61131-3 languages, not RSLogix 500. Logic is rebuilt and tested, not just copied.

I/O and ports

We compare embedded I/O, expansion modules and serial or Ethernet ports so nothing is lost.

Serial protocols

If you use DF1 or Modbus on serial ports, we confirm the same function on the new controller.

03How we run it

Our migration process

  • Migration readiness audit: inventory of hardware, firmware, networks, programs and spares
  • Back up and document the running system before anything is touched
  • Design the target architecture and I/O mapping; agree scope and the cutover approach
  • Convert and rebuild the program and HMI, with every conversion warning reviewed by hand
  • Test in stages: simulation, panel factory test where panels are built, then site testing
  • Cutover with a rollback plan, then handover documentation

What we need from you: Program backups (or access to the running processor); Electrical drawings and the I/O list, if available; Network layout and device list; Photos of nameplates, panels and wiring; Your shutdown windows and any safety requirements.

04Related searches

What people look up

  • micrologix 1000 to micro800 migration
  • micrologix 1100 replacement
  • micrologix 1200 to micro800 upgrade
  • micrologix 1400 to micro800 migration
  • micrologix 1500 to compactlogix migration
06FAQ

Common questions

What is the replacement for MicroLogix 1400?
Usually a Micro800 controller or a small CompactLogix, depending on I/O, communications and budget.
Do I have to rewrite the program?
The logic is rebuilt in the new software and tested. We review it line by line rather than rely on automatic conversion alone.

Planning this migration?

Send what you have — model numbers, a photo of the panel, or just the problem. We reply the same day with next steps. Chennai, Puducherry, Bengaluru, Hyderabad, Delhi and pan-India.

Star Automations is an independent company. Allen-Bradley, Rockwell Automation, ControlLogix, CompactLogix, GuardLogix, PanelView, PowerFlex, Kinetix, FactoryTalk and Studio 5000 are trademarks of Rockwell Automation, Inc. They are used here only to identify the products we work on and do not imply endorsement by, or partnership with, Rockwell Automation.