ABB · Drives
ACS880-01-25A-3 — ABB ACS880 industrial drive: fault codes, repair & supply
The ACS880-01-25A-3 is a wall-mounted ABB ACS880-01 industrial AC drive in the 25 A, 380–415 V class. Star Automations sources and supplies the ACS880-01-25A-3 and repairs failed units at component level, so you can choose between a replacement and getting your existing unit restored. This is a current OEM line. Availability and price are confirmed per enquiry. Most quotes come back the same day — send the part number or the fault code on WhatsApp.

Common ABB ACS880 fault codes and what we usually find
Fault code wording can differ by firmware and manual revision — always confirm against the manual for your exact unit. The causes below are typical findings, not a diagnosis of your specific unit.
| Code | Meaning | Typical cause |
|---|---|---|
| 2310 | OVERCURRENT | Failed output IGBT stage, motor cable short or insulation breakdown |
| 2330 | EARTH LEAKAGE | Motor or cable insulation fault, damaged current measurement |
| 3130 | INPUT PHASE LOSS | Blown input fuse, loose supply terminal, failed rectifier |
| 3210 | DC LINK OVERVOLTAGE | Ramp too fast, failed brake chopper or resistor, aged DC capacitors |
| 3220 | DC LINK UNDERVOLTAGE | Supply sag, precharge or rectifier fault, weak DC capacitors |
| 4210 | IGBT OVERTEMPERATURE | Blocked heatsink, failed cooling fan, degraded thermal path |
When a ACS880-01-25A-3 needs attention
- Drive trips as soon as it starts or only under load
- Panel shows a fault code and will not reset
- Display is dark or the drive does not power up
- Cooling fan noisy, slow or not running
- Burnt smell, discoloured board or bulging capacitors
- Repeated overcurrent or earth-fault trips with a known-good motor
Replace or repair your ACS880-01-25A-3
Source a replacement
Send the part number. We check sourcing from global surplus and the OEM channel and reply the same day with availability, condition and price. Advance or verified escrow applies.
Repair your existing unit
If sourcing takes longer or you want to keep your configuration, we repair at component level — power stage, gate-drive, control and supply sections — and test before dispatch.
What people look up for the ACS880-01-25A-3
- ACS880 fault 2310 overcurrent
- ACS880 DC link overvoltage 3210
- ACS880-01-25A-3 repair
- ABB ACS880 drive repair India
- ACS880 earth leakage fault 2330
ACS880-01-25A-3 — common questions
Can you supply the ACS880-01-25A-3 in India?
Can a faulty ACS880-01-25A-3 be repaired instead of replaced?
My ACS880-01-25A-3 shows 2310 (overcurrent). What should I do?
Is the exact part number important?
Need the ACS880-01-25A-3 now?
Send the part number or fault code — we reply the same day. Serving Chennai, Puducherry, Bengaluru, Hyderabad, Delhi and pan-India.